The Sporlan Kelvin II Series valve controllers provide unmatched control of electric valves for a variety of applications.
Literature and Reference Materials |
---|
Form 100-543 - Sporlan Electronic Components Quick Selection |
Products | Type | Input Voltage (VDC) | Communication Port | Indicator Type | Pressure Range (psig) | Sensor type | Display Type | Wiring | Minimum Working Temperature (F) | Operating Humidity | Number of Outputs | Application | Number of Inputs | Mounting | Maximum Working Temperature (F) | Minimum Operating Temperature (F) | Maximum Operating Temperature (F) | Length (inch) | Keypad/User Interface Option | Enclosure | Degree of Protection (IP) | Operating Style | Connection | Signal Output | Signal Input | Cable Length | Controller Type | Input Voltage (VAC) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
952567 | Kelvin II Controller | 22-26.6 VDC; Class II Input | RS 485, Modbus | LED- Red, Power | N/A | N/A | Digital LED- Red, 7 Segment, 4 Digit | Screw Terminal | N/A | 0-95% Relative Humidity (Non- Condensing) | 2 | Refrigeration Control | 5 | DIN Rail- EN 50 022 | N/A | -40° | 158° | N/A | Optical Encoder (SELECT knob) | PC- Light Gray | N/A | N/A | N/A | Relay: 100-240 VAC , 3A ind/250 V, 22-28 VDC, 250 mA Digital Output with Ground (Not Currently Used) | Digital: 0-5 VDC Maximum Range (Interface to Dry Contact or Open Collector), Analog: 4 Temperature Sensors- 2 Kohm (*3 Kohm Optional), 1 Pressure Transducer .5-4.5 VR | N/A | Stand Alone Controller- With Display | 20-26 VAC |
952568 | Kelvin II Controller | 22-26.6 VDC; Class II Input | RS 485, Modbus | LED- Red, Power | N/A | N/A | Digital, Remote, LED- Red, 7 Segment, 4 Digit | Screw Terminal | N/A | 0-95% Relative Humidity (Non- Condensing) | 2 | Refrigeration Control | 5 | DIN Rail- EN 50 022 | N/A | -40° | 158° | N/A | Optical Encoder (SELECT knob) | PC- Light Gray | N/A | N/A | N/A | Relay: 100-240 VAC , 3A ind/250 V, 22-28 VDC, 250 mA Digital Output with Ground (Not Currently Used) | Digital: 0-5 VDC Maximum Range (Interface to Dry Contact or Open Collector), Analog: 4 Temperature Sensors- 2 Kohm (*3 Kohm Optional), 1 Pressure Transducer .5-4.5 VR | N/A | Remote Diplay Unit | 20-26 VAC |
952569 | Kelvin II Controller | 22-26.6 VDC; Class II Input | RS 485, Modbus | LED- Red, Power | N/A | N/A | No Display | Screw Terminal | N/A | 0-95% Relative Humidity (Non- Condensing) | 2 | Refrigeration Control | 5 | DIN Rail- EN 50 022 | N/A | -40° | 158° | N/A | Optical Encoder (SELECT knob) | PC- Light Gray | N/A | N/A | N/A | Relay: 100-240 VAC , 3A ind/250 V, 22-28 VDC, 250 mA Digital Output with Ground (Not Currently Used) | Digital: 0-5 VDC Maximum Range (Interface to Dry Contact or Open Collector), Analog: 4 Temperature Sensors- 2 Kohm (*3 Kohm Optional), 1 Pressure Transducer .5-4.5 VR | N/A | Stand Alone Controller- No Display | 20-26 VAC |
952570 | Subcool Controller | 22-26.6 VDC; Class II Input | RS485, Modbus | LED- Red, 7 Segment, 4 Digit; LED- Red, Power | N/A | N/A | Digital LED | Screw Terminal | N/A | 0-95% Relative Humidity (Non- Condensing) | 0 | N/A | 6 | DIN Rail- EN 50 022 | N/A | -40° | 158° | N/A | Optical Encoder (SELECT knob) | PC- Light Gray | N/A | N/A | N/A | N/A | Digital: 0-5 VDC Maximum Range (Interface to Dry Contact or Open Collector), Analog: 4 Temperature Sensors- 2 Kohm (*3 Kohm Optional), 1 Pressure Transducer .5-4.5 VR (*150 psgi, 300psgi, or 500 psig) | N/A | Local Display | 20-26 VAC |
953463 | Chiller Controller | 22-26.6 VDC; Class II Input | RS485, Modbus, BACnet | LED- Red, 7 Segment, 4 Digit; LED- Red, Power | N/A | N/A | Digital LED | Screw Terminal | N/A | 0-95% Relative Humidity (Non- Condensing) | 0 | N/A | 6 | DIN Rail- EN 50 022 | N/A | -40° | 158° | N/A | Optical Encoder (SELECT knob) | PC- Light Gray | N/A | N/A | N/A | N/A | Digital: 0-5 VDC Maximum Range (Interface to Dry Contact or Open Collector), Analog: 4 Temperature Sensors- 2 Kohm (*3 Kohm Optional), 1 Pressure Transducer .5-4.5 VR (*150 psig/ 0-10.3 bar, 300 psig/0-20.7 bar, 500 psig/ 0-34.5 bar) | N/A | Local Display | 20-26 VAC |
953474 | Pressure Controller | 22-26.6 VDC; Class II Input | RS485, Modbus | LED- Red, 7 Segment, 4 Digit; LED- Red, Power | N/A | N/A | Digital LED | Screw Terminal, 12-24 AWG | N/A | 0-95% Relative Humidity (Non- Condensing) | 2 | N/A | 6 | DIN Rail- EN 50 022 | N/A | -40° | 158° | N/A | Optical Encoder (SELECT knob) | PC- Light Gray | N/A | N/A | N/A | Relay: 100-240 VAC , 3A ind/250 V, 22-28 VDC, 250 mA Digital Output with Ground (Not Currently Used) | Digital: 0-5 VDC Maximum Range (Interface to Dry Contact or Open Collector), Analog: 4 Temperature Sensors- (2 Kohm, 3 Kohm, or 98.6 Kohm), 1 Pressure Transducer .5-4.5 VR (*150psiA, 150 psig, 300 psig, or 500 psig) | N/A | Standalone Controller With Display | 20-26 VAC |