To give you the best possible experience, this site uses cookies. By continuing to use the site, or by staying here, you agree to our use of cookies in line with our
Privacy Policy.
Learn more including how to manage cookies
here.
To give you the best possible experience, this site uses cookies. By continuing to use the site, or by staying here, you agree to our use of cookies in line with ourPrivacy Policy. Learn more including how to manage cookies here.
Search
Invalid search criteria
The Parker Service Master COMPACT | Product Series
var attrArray = new Array();
var attrValueMap = {};
attrValueMap['Product Type'] = 'Measuring device ';
attrValueMap['Calibration Type'] = 'Calibration Certificate (ISO 9001) ';
attrValueMap['Version'] = 'ANALOG/AUX ';
attrValueMap['Includes'] = 'Cable USB A - USB C - 1m ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Product Type'] = 'Measuring device ';
attrValueMap['Version'] = 'CAN/AUX ';
attrValueMap['Calibration Type'] = 'Calibration Certificate (ISO 9001) ';
attrValueMap['Includes'] = 'Cable USB A - USB C - 1m ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Includes'] = 'Battery for SCM 370 ';
attrValueMap['Version'] = '- ';
attrValueMap['Calibration Type'] = '- ';
attrValueMap['Product Type'] = 'Spare Part ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Includes'] = 'Outdoor case ';
attrValueMap['Product Type'] = 'Optional Accessories ';
attrValueMap['Version'] = '- ';
attrValueMap['Calibration Type'] = '- ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Product Type'] = 'Optional Accessories ';
attrValueMap['Includes'] = 'Cable USB A - USB C - 1m ';
attrValueMap['Version'] = '- ';
attrValueMap['Calibration Type'] = '- ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Product Type'] = 'Optional Accessories ';
attrValueMap['Includes'] = 'Cable USB C - USB C - 1m ';
attrValueMap['Version'] = '- ';
attrValueMap['Calibration Type'] = '- ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Includes'] = 'Cable, adapter, test hose and quick charging power supply ';
attrValueMap['Version'] = 'ANALOG/AUX ';
attrValueMap['Product Type'] = 'Measuring device in case with accessory ';
attrValueMap['Calibration Type'] = '- ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Includes'] = 'Pressure sensors, temprature sensor, flow sensor, cable, adapter, test hose and quick charging power supply ';
attrValueMap['Version'] = 'ANALOG/AUX ';
attrValueMap['Product Type'] = 'Measuring device in case with accessory ';
attrValueMap['Calibration Type'] = '- ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Version'] = 'CAN/AUX ';
attrValueMap['Includes'] = 'Cable, adapter, test hose and quick charging power supply ';
attrValueMap['Product Type'] = 'Measuring device in case with accessory ';
attrValueMap['Calibration Type'] = '- ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Includes'] = 'Cable, adapter, test hose and quick charging power supply ';
attrValueMap['Product Type'] = 'Measuring device in case with accessory ';
attrValueMap['Version'] = 'CAN ';
attrValueMap['Calibration Type'] = '- ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Product Type'] = 'Measuring device ';
attrValueMap['Version'] = 'ANALOG/AUX ';
attrValueMap['Includes'] = 'Cable USB A - USB C - 1m ';
attrValueMap['Calibration Type'] = '- ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Product Type'] = 'Measuring device ';
attrValueMap['Version'] = 'CAN/AUX ';
attrValueMap['Includes'] = 'Cable USB A - USB C - 1m ';
attrValueMap['Calibration Type'] = '- ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Product Type'] = 'Measuring device ';
attrValueMap['Includes'] = 'Cable USB A - USB C - 1m ';
attrValueMap['Version'] = 'CAN ';
attrValueMap['Calibration Type'] = '- ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Includes'] = 'Protective cap set (set with caps for all versions) ';
attrValueMap['Version'] = '- ';
attrValueMap['Calibration Type'] = '- ';
attrValueMap['Product Type'] = 'Spare Part ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Includes'] = 'Display protection (1 pc.) ';
attrValueMap['Product Type'] = 'Optional Accessories ';
attrValueMap['Version'] = '- ';
attrValueMap['Calibration Type'] = '- ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Includes'] = 'Rubber protection + Standing bracket ';
attrValueMap['Version'] = '- ';
attrValueMap['Calibration Type'] = '- ';
attrValueMap['Product Type'] = 'Spare Part ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Product Type'] = 'Optional Accessories ';
attrValueMap['Includes'] = 'Car charging cable 12/24VDC with USB-C plug ';
attrValueMap['Version'] = '- ';
attrValueMap['Calibration Type'] = '- ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Product Type'] = 'Optional Accessories ';
attrValueMap['Includes'] = 'Quick charging power supply (66 W) incl. USB cable (C auf C) und adapter (EUR/UK/US) ';
attrValueMap['Version'] = '- ';
attrValueMap['Calibration Type'] = '- ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Product Type'] = 'Optional Accessories ';
attrValueMap['Includes'] = 'Touch pen (Parker) ';
attrValueMap['Version'] = '- ';
attrValueMap['Calibration Type'] = '- ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Product Type'] = 'Optional Accessories ';
attrValueMap['Includes'] = 'M12x1 plug for external sensor inputs ';
attrValueMap['Version'] = '- ';
attrValueMap['Calibration Type'] = '- ';
attrArray.push(attrValueMap);
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.....
Click here to view all product safety information.
Full Product Description
The Parker Service Master COMPACT is a universally appliable measuring device for service applications in mobile and stationary hydraulics. The device is available in 3 versions, for Parker CAN or analogue sensors with automatic sensor recognition and optional industrial analogue sensors. Due to a wide range of sensors it can be flexibly used in hydraulic applications. For example, for service and maintenace, system validation or performance optimization. Parker sensors with integrated sensor recognition alow plug and play measurements. After plug in, manual parameterizing of the measurement signal and measuring range is no longer necessary ā independent if pressure, temperature, flow or rpm sensors. Parameters are displayed in real time and can be recorded at the touch of a button or triggered by defined signals. Different test kits are available.
Markets: ⢠Maintenance and Repair, MRO ⢠Mobile ⢠Agriculture ⢠Construction ⢠Transportation ⢠Defence ⢠Industrial ⢠Molding ⢠Testing
Applications: ⢠Mobile equipment ⢠Industrial hydraulic systems ⢠Fluid or gas maintenace and trouble shooting ⢠System performance optimization ⢠System validation ⢠Test equipment and technology ⢠Cooling systems
Features/benefits: ⢠Versions with different measuring inputs: Parker analog or ParkerCAN sensors with sensor recognition and optional industrial analog sensors ⢠Measure and display up to 16 channels ⢠Intuitive operation using the colored 4,3ā touch display, Suitable for use with gloves, resolution 800 x 480 pixels ⢠Additional tactile keyboard for operation even under difficult conditions ⢠Rugged, oil-resistant protection for use in harsh conditions and for shock absorption ⢠Practical storage concept with integrated portable USB stick ⢠Templates for recurring measurements ⢠Start/Stop measuerement with automatic data compression or manual adjustment of storage time and rate ⢠Screenshot function ⢠Templates for recurring measurements ⢠SensoWin software allows online measurement and deeper analysis and documentation of downloaded measurements