2-Way High-Response Valve with Shut-Off Valve - Series TEP | #TEP050EH99C2HB7J


LOADING IMAGES
TEP050EH99C2HB7J
Click to View CAD Model

2-Way High-Response Valve with Shut-Off Valve - Series TEP | #TEP050EH99C2HB7J

2-way high-response valves series TEP in cartridge design base on the TDP range and provide a precise control of high flows at maximum dynamics. Additionally, TEP valves are equipped with a direction control valve for shutting off the pilot system.


Technical Specifications

  • Port Connection: NG50
  • Seal Material: for HFC fluid
  • Poppet Style: Linear
  • Optional Accessories: With position control
  • Mounting Style: Slip-in cartridge
  • Signal Input: 0 - +10 V
  • Product Series: High-response valve
  • Operation Type: Pilot
  • Actuation Type: VCD actuator
  • Electronics Type: Onboard
  • Function: 2-way
  • Performance: High response for controlled apoplications
  • Pilot Inlet / Drain Locations: External/external
  • Mounting Type: Slip-in cartridge
  • Mounting Position: Unrestricted
  • Configuration: N/A
  • Maximum Operating Pressure: 350 bar
  • Flow Rate: N/A
  • Maximum Flow Rate: 1900
  • Maximum Operating Temperature: 50 °C
  • Minimum Operating Temperature: -20 °C
  • Seal Material: For HFC fluid
  • For Fluid Type: Water glycol, Hydraulic Oil
  • Weight: 26 kg
  • Body Material: Steel
  • Maximum Fluid Temperature: 60 °C
  • Minimum Fluid Temperature: -25 °C
  • Operating Temperature: -20 to 50 °C
  • Port Connection: NG050
  • Signal Input: 0 to +10 VDC
  • Filter Efficiency Rating: ISO 4406, 18/16/13
  • Specifications Met: ISO 7368
Safety Warning

Item Information

Parker’s 2-way high-response valves with shut-off valve series TEP in cartridge design are particularly suitable for demanding controlled and closed loop applications where high flow has to be precisely controlled at highest dynamics. TEP valves have a 2-stage design consisting of a DFplus pilot valve and a main stage with poppet and LVDT. Additionally, they are equipped with a direction control valve with position control for shutting off the pilot system.



Markets:

• Industrial

• Molding



Features/Benefits:

• High precision – for high quality products, minimum scrap rate and long machine lifetime

• Extremely fast step response – shortens material processing and thus cycle times

• Short delivery time – no warehousing necessary

• Active pilot operated 2-way high-response valve with shut-off valve

• Flow directions A-B and B-A

• Cavity and mounting pattern according to ISO 7368

• Completely mounted and adapted unit with integrated electronics

• Fail save position at electrical and/or hydraulic power down

• 8 sizes

• Shut-off function



Applications:

• General presses

• Injection molding

• Die cast


Function:
With the DFplus pilot valve the TEP achieves extremely fast response times: from 10.5 ms (NG25) up to 28 ms (NG100) with an accuracy of <0.1 % of the nominal flow. The pilot valve actively controls the poppet – independent of the pressure conditions in the main ports. The integrated electronics in the pilot of the TEP has two control loops for the main poppet and the pilot spool.  

In the de-energized position of the shut-off valve, the upper pilot control surface of the main spool is pressurized, the lower one is relieved to tank. Without pilot pressure, the main spool is closed by spring force. Independent of the DFplus pilot valve, the main spool remains always closed, if the shut-off valve is not activated.

If the solenoid of the shut-off-valve is energized, the position of the main spool is controlled by DFplus pilot valve and LVDT.

Please note:
It is basically required that the pilot pressure is at the level of the system pressure. At low system pressure the pilot pressure should be min. 140 bar, when high valve dynamics are desired.

In order to ensure the closed position, pilot pressure is required.

Read More Show Less

CAD Drawings + Files


Related Documents

×

Quantity:
Request a Quote

The item has been successfully added to your quote cart Go to Quote Cart

x

Ok

x

Find a Distributor

Where to Buy

Local Contact

South Africa Headoffice

Parker Hannifin (Africa) Pty LTD

Sales Company South Africa

10 Berne Avenue

Aeroport

Kempton Park

Gauteng

South Africa

1620

Phone

0027 11 961 0700

Get your Parker account Today!

Create one account to manage everything you do with Parker, from your shopping preferences to your application access.

687466