Parker's Vent Master™ is designed to isolate the analyzer from fluctuating outlet pressures by controlling the pressure of the collection header and pumping the effluent sample gases into the fluctuating return system.


Technical Specifications

  • Rotameter Range: 0 to 30 SLPM
  • Eductor: A
  • Model Number: EDR
  • Connection Style: Single Ferrule Fitting
  • Options: Regulator with Tube Fitting Assembly
  • Model Number: EDR
  • Eductor Type: A
  • Flow Meter: 0 to 30 SLPM
  • Options: Regulator with Tube Fitting Assembly
  • Connection Type: Single Ferrule Fitting
Safety Warning

Item Information

Parker’s VentMaster is an easy to operate “all in one “system. After a process sample stream is analyzed, it must be disposed of in a manner consistent with environmental regulations. It has been common practice to simply vent the sample stream to the atmosphere. As environmental regulations become more stringent, it is becoming undesirable, if not illegal, to admit these samples to the atmosphere. For an analyzer to operate correctly, it must be calibrated and operated under the same conditions. These critical conditions are temperature, flow and pressure, with the pressure of the measurement cell being the most critical. Venting analyzer effluent to atmosphere is not only convenient, but it also provides a very stable reference pressure for the analyzer measurement cell. In other words, the measurement cell “floats” on atmospheric pressure. Analyzer outlet sample streams are traditionally collected into a closed vent header. This vent header either flows to atmosphere or back to the process. When atmospheric venting is not allowed, the most common disposal point is the plant flare where the analyte sample stream is burned. However, the flare header is subject to pressure variations as high as 20 psig or more as process upsets create backpressure. When venting an analyzer into the flare collection system, the measurement cell “floats” on these varying pressures. If this condition is left unchecked these pressure fluctuations will result in significant analyzer measurement errors.

Markets:
• Chemical
• Petro-Chemical
• Oil and Gas

Features/Benefits:
• Easy to use “Passive” system
• Compact, bolt to the wall package

Applications:
• Process Headers
• Instrumentation System Shelters

Read More Show Less

CAD Drawings + Files

No CAD files available

Ok

x

Related Documents

×

Quantity:
Request a Quote

The item has been successfully added to your quote cart Go to Quote Cart

x

Ok

x

Find a Distributor

Where to Buy

Local Contact

South Africa Headoffice

Parker Hannifin (Africa) Pty LTD

Sales Company South Africa

10 Berne Avenue

Aeroport

Kempton Park

Gauteng

South Africa

1620

Phone

0027 11 961 0700

Get your Parker account Today!

Create one account to manage everything you do with Parker, from your shopping preferences to your application access.

687466
687516