Technical Specifications

  • Flow Rate: 106 GAL/MIN, 400 L/MIN
  • Maximum Inlet Pressure Rating: 6000 PSI, 420 BAR
  • Pressure Control Range: 145-3000 PSI, 10-210 BAR
  • Adjustment Mechanism: Tamper Resistant
  • Seal Material: Nitrile
  • Division: Mobile Hydraulic Systems Division Europe
  • Flow Rate: 106 gal/min, 400 L/min
  • Maximum Inlet Pressure Rating: 6000 psi, 420 bar
  • Pressure Control Range: 145 to 3000 psi, 10 to 210 bar
  • Adjustment Mechanism: Tamper Resistant
  • Seal Material: Nitrile
  • Maximum Flow Rate: 106 gal/min, 400 L/min
  • Maximum Operating Pressure: 6000 psi, 420 bar
  • Maximum Tank Pressure: 6000 psi, 420 bar
  • Standard Setting Pressure: 1450 psi, 100 bar
  • Maximum Pressure Setting: 3000 psi, 210 bar
  • Pressure Control Sensitivity: 435 psi Per Turn, 30 bar Per Turn
  • Reseat Pressure: n/a
  • Actuation Type: Pressure Sensing
  • Configuration: Pressure Relief
  • Leak Rate: 100 cm3/min @ 1450 Psi (100 bar)
  • Mounting Type: Screw-in Cartridge
  • Cavity Size: C16-2
  • Function: Pilot Operated
  • Operation Type: Automatic
  • For Fluid Type: Mineral-based Hydraulic Fluids, Synthetic Hydraulic Fluids
  • Maximum Kinematic Viscosity: 45-2000 SSU (6 to 420 cSt)
  • Filter Efficiency Rating: ISO 4406 18/16/13, SAE Class 4
  • Valve Material: Steel (all parts), Hardened Steel (all operating parts)
  • Installation Torque: 74 lb-ft, 100 Nm
  • Operating Temperature: -30 to 250 °F, -34 to 121 °C
  • Maximum Operating Temperature: 250 °F, 121 °C
  • Minimum Operating Temperature: -30 °F, -34 °C
  • Weight: 1.26 lb, 0.57 kg
  • Body Material: n/a
Safety Warning

Item Information

Pilot operated relief valves are available is -08 to -20 size cavity configurations. This family of valves is best suited for continuous duty systems where the valve is asked to operate beyond any intermittent use. They can be used to maintain system pressure for long periods of time. Additionally, where systems may have large rates of change in flow, the pilot operated valves can accommodate these changes without excessive pressure rise or sometimes called pressure override. Due to the flow opening areas through the valve, these spool type valves will operate more quietly than a conventional direct acting valve. One must also consider the leakage component as the spool is, by design, going to pass a small leakage flow, whereas a direct acting valve does not pass significant flow until the cracking pressure is reached. Spool type relief valves should not be used in load holding application. Pilot operated relief valves are designed for continuous duty applications. Due to their stability and low pressure rise, the pilot operated relief is the best option for setting the pressure of a hydraulic system. Common circuit applications include: Cross port relief, swing relief, port relief, system relief, pressure limiting, spike relief, motor braking, pressure limiter, steering and low limiting.

Read More Show Less

CAD Drawings + Files

Part Number
A06G2HTN IGS STP

Ok

x

Related Documents

×

Quantity:
Request a Quote

The item has been successfully added to your quote cart Go to Quote Cart

x

Ok

x

Find a Distributor

Where to Buy

Local Contact

South Africa Headoffice

Parker Hannifin (Africa) Pty LTD

Sales Company South Africa

10 Berne Avenue

Aeroport

Kempton Park

Gauteng

South Africa

1620

Phone

0027 11 961 0700

Get your Parker account Today!

Create one account to manage everything you do with Parker, from your shopping preferences to your application access.

687466
327264