Adaptomode Outlet Regulators - A4A Series | #A424V250A7S25R1XNXSN


LOADING IMAGES
A424V250A7S25R1XNXSN

Adaptomode Outlet Regulators - A4A Series | #A424V250A7S25R1XNXSN

1 A4AOES RV 1SW 24/DC


Technical Specifications

  • Check Valve Type: None
  • Pressure Regulator Type: Outlet- Externally Equalized with Electric Shut-Off
  • Pressure Set Point (psig): 40psig
  • Valve Material: Standard Valve Material
  • Pressure Set Point (bar): 2.8bar
  • Connection Size: 1"
  • Strainer Type: Without Strainer
  • Flange Type: Socket Weld
  • Port Size (mm): 25mm
  • Capacity Plug: Full Capacity
  • Motor Type: None
  • Coil Type: 24DC-Leaded Standard
  • Port Size (inch): 1"
  • Model Number: 1 A4AOES RV 1SW 24/DC
  • Product Type: A4A0ES
  • Minimum Operating Temperature: -45 °C, -50 °F
  • Maximum Operating Temperature: 105 °C, 220 °F
  • Maximum Operating Pressure: 27.6 bar, 400 psig
  • Body Material: Gray Iron
  • Flow Coefficient: 8.6 Kv, 10 Cv
  • Pressure Regulator Type: Outlet - Externally Equalized with Electric Shut-Off
  • Pressure Rating: 500 mm-Hg to 8.3 bar, 20 inch-Hg to 120 bar
  • Port Size: 25 mm, 1 inch
  • Capacity Plug Type: Full Capacity
  • Pressure Set Point: 2.8 bar, 40 psig
  • Flange Face Type: Socket Weld
  • Connection Size: 1 inch
  • Coil Type: 24VDC, Leaded Standard
  • Motor Type: None
  • Strainer Type: Without Strainer
  • Check Valve Included: None
  • Valve Material: Standard Material
  • Plating Type: No Plating
Safety Warning

Item Information

The A4A outlet family of regulators are compact, heavy duty, pilot operated, and have remarkable functionality. The regulator will gradually close when downstream pressure begins to rise above the setting and will gradually open when pressure begins to fall below the setting. The regulator cannot maintain set-for pressure if uncontrolled branch pipe lines feed into the main pipeline downstream of the regulator. The valve’s purpose is to modulate flow of refrigerant gas or liquid to maintain constant downstream pressure as set-for, despite load fluctuations.

Markets:
• Industrial Refrigeration
• Commercial Refrigeration

Features and Benefits:
• Pilot operated characterized Modulating Plug for precise control
• Suitable for all common refrigerants and oil
• 28bar (406psig) design pressure (MRP)
• Unique modular construction
• Flanges threaded or welded steel pipe and copper tube (copper not for ammonia)
• Interchangeable parts
• Easy to service
• Close coupled strainers, optional
• Many control variations are possible with the use of a few Modules and Kits
• Stainless Steel Diaphragm
• Chrome Plated Pilot Seat
• Manual Opening Stem

Application:
• Depending on the specific variation of this valve, the application may include, but is not limited to;   
• Compressor Motor overload prevention, Hot Gas Bypass Capacity Control, limiting refrigerant pressure in a liquid line, deep vacuum prevention in booster suction, Pressure Rise prevention in suction main, Hot Gas Defrost Control

Read More Show Less

CAD Drawings + Files

No CAD files available

Ok

x

Related Documents

×

Quantity:
Request a Quote

The item has been successfully added to your quote cart Go to Quote Cart

x

Ok

x

Find a Distributor

Where to Buy

Local Contact

South Africa Headoffice

Parker Hannifin (Africa) Pty LTD

Sales Company South Africa

10 Berne Avenue

Aeroport

Kempton Park

Gauteng

South Africa

1620

Phone

0027 11 961 0700

Get your Parker account Today!

Create one account to manage everything you do with Parker, from your shopping preferences to your application access.

687466
687475