The maximum number of products that can be compared is 4. Please refine your selection.
Your session is about to timeout due to inactivity. Click OK to extend your time for an additional 0 minutes.
Q series
318634
false
[
]
This item has been successfully added to your list.
To give you the best possible experience, this site uses cookies. By continuing to use the site, or by staying here, you agree to our use of cookies in line with our
Privacy Policy.
Learn more including how to manage cookies
here.
Technopolymer Solenoid Valve for Beverage Dispense Applications - Q Series | Product Series
var attrArray = new Array();
var attrValueMap = {};
attrValueMap['Port Size'] = '6,0 mm ';
attrValueMap['Exhaust Orifice Size'] = '1,6 mm ';
attrValueMap['Maximum Operating Pressure'] = '14 bar AC/DC ';
attrValueMap['Valve Type'] = '3/2 ';
attrValueMap['Flow Coefficient 1'] = '0,7 l/min ';
attrValueMap['Orifice Size'] = '1,2 mm ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Exhaust Orifice Size'] = '- ';
attrValueMap['Maximum Operating Pressure'] = '15 bar AC - 12 bar DC ';
attrValueMap['Valve Type'] = '2/2 Way ';
attrValueMap['Port Size'] = '4,0 mm ';
attrValueMap['Flow Coefficient 1'] = '0,7 l/min ';
attrValueMap['Orifice Size'] = '1,2 mm ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Exhaust Orifice Size'] = '- ';
attrValueMap['Valve Type'] = '2/2 Way ';
attrValueMap['Flow Coefficient 1'] = '1 l/min ';
attrValueMap['Port Size'] = '4,0 mm ';
attrValueMap['Maximum Operating Pressure'] = '15 bar AC - 10 bar DC ';
attrValueMap['Orifice Size'] = '1,5 mm ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Exhaust Orifice Size'] = '- ';
attrValueMap['Valve Type'] = '2/2 Way ';
attrValueMap['Maximum Operating Pressure'] = '10 bar AC - 4 bar DC ';
attrValueMap['Port Size'] = '4,0 mm ';
attrValueMap['Flow Coefficient 1'] = '2,3 l/min ';
attrValueMap['Orifice Size'] = '2,5 mm ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Exhaust Orifice Size'] = '- ';
attrValueMap['Maximum Operating Pressure'] = '15 bar AC - 12 bar DC ';
attrValueMap['Port Size'] = '6,0 mm ';
attrValueMap['Valve Type'] = '2/2 Way ';
attrValueMap['Flow Coefficient 1'] = '0,7 l/min ';
attrValueMap['Orifice Size'] = '1,2 mm ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Exhaust Orifice Size'] = '- ';
attrValueMap['Port Size'] = '6,0 mm ';
attrValueMap['Valve Type'] = '2/2 Way ';
attrValueMap['Flow Coefficient 1'] = '1 l/min ';
attrValueMap['Maximum Operating Pressure'] = '15 bar AC - 10 bar DC ';
attrValueMap['Orifice Size'] = '1,5 mm ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Exhaust Orifice Size'] = '- ';
attrValueMap['Port Size'] = '6,0 mm ';
attrValueMap['Valve Type'] = '2/2 Way ';
attrValueMap['Maximum Operating Pressure'] = '10 bar AC - 4 bar DC ';
attrValueMap['Flow Coefficient 1'] = '2,3 l/min ';
attrValueMap['Orifice Size'] = '2,5 mm ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Exhaust Orifice Size'] = '1,6 mm ';
attrValueMap['Maximum Operating Pressure'] = '14 bar AC/DC ';
attrValueMap['Valve Type'] = '3/2 Way ';
attrValueMap['Port Size'] = '4,0 mm ';
attrValueMap['Flow Coefficient 1'] = '0,7 l/min ';
attrValueMap['Orifice Size'] = '1,2 mm ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Exhaust Orifice Size'] = '1,6 mm ';
attrValueMap['Valve Type'] = '3/2 Way ';
attrValueMap['Flow Coefficient 1'] = '1 l/min ';
attrValueMap['Port Size'] = '4,0 mm ';
attrValueMap['Orifice Size'] = '1,5 mm ';
attrValueMap['Maximum Operating Pressure'] = '8 bar AC/DC ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Exhaust Orifice Size'] = '1,6 mm ';
attrValueMap['Valve Type'] = '3/2 Way ';
attrValueMap['Port Size'] = '4,0 mm ';
attrValueMap['Maximum Operating Pressure'] = '3 bar AC/DC ';
attrValueMap['Flow Coefficient 1'] = '2,3 l/min ';
attrValueMap['Orifice Size'] = '2,5 mm ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Size'] = '6,0 mm ';
attrValueMap['Exhaust Orifice Size'] = '1,6 mm ';
attrValueMap['Maximum Operating Pressure'] = '14 bar AC/DC ';
attrValueMap['Valve Type'] = '3/2 Way ';
attrValueMap['Flow Coefficient 1'] = '0,7 l/min ';
attrValueMap['Orifice Size'] = '1,2 mm ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Size'] = '6,0 mm ';
attrValueMap['Exhaust Orifice Size'] = '1,6 mm ';
attrValueMap['Valve Type'] = '3/2 Way ';
attrValueMap['Flow Coefficient 1'] = '1 l/min ';
attrValueMap['Orifice Size'] = '1,5 mm ';
attrValueMap['Maximum Operating Pressure'] = '8 bar AC/DC ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Size'] = '6,0 mm ';
attrValueMap['Exhaust Orifice Size'] = '1,6 mm ';
attrValueMap['Valve Type'] = '3/2 Way ';
attrValueMap['Maximum Operating Pressure'] = '3 bar AC/DC ';
attrValueMap['Flow Coefficient 1'] = '2,3 l/min ';
attrValueMap['Orifice Size'] = '2,5 mm ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Exhaust Orifice Size'] = '1,6 mm ';
attrValueMap['Maximum Operating Pressure'] = '14 bar AC/DC ';
attrValueMap['Valve Type'] = '3/2 Way ';
attrValueMap['Port Size'] = '4,0 mm ';
attrValueMap['Flow Coefficient 1'] = '0,7 l/min ';
attrValueMap['Orifice Size'] = '1,2 mm ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Exhaust Orifice Size'] = '1,6 mm ';
attrValueMap['Valve Type'] = '3/2 Way ';
attrValueMap['Flow Coefficient 1'] = '1 l/min ';
attrValueMap['Port Size'] = '4,0 mm ';
attrValueMap['Orifice Size'] = '1,5 mm ';
attrValueMap['Maximum Operating Pressure'] = '8 bar AC/DC ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Exhaust Orifice Size'] = '1,6 mm ';
attrValueMap['Valve Type'] = '3/2 Way ';
attrValueMap['Port Size'] = '4,0 mm ';
attrValueMap['Maximum Operating Pressure'] = '3 bar AC/DC ';
attrValueMap['Flow Coefficient 1'] = '2,3 l/min ';
attrValueMap['Orifice Size'] = '2,5 mm ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Size'] = '6,0 mm ';
attrValueMap['Exhaust Orifice Size'] = '1,6 mm ';
attrValueMap['Maximum Operating Pressure'] = '14 bar AC/DC ';
attrValueMap['Valve Type'] = '3/2 Way ';
attrValueMap['Flow Coefficient 1'] = '0,7 l/min ';
attrValueMap['Orifice Size'] = '1,2 mm ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Size'] = '6,0 mm ';
attrValueMap['Exhaust Orifice Size'] = '1,6 mm ';
attrValueMap['Valve Type'] = '3/2 Way ';
attrValueMap['Flow Coefficient 1'] = '1 l/min ';
attrValueMap['Orifice Size'] = '1,5 mm ';
attrValueMap['Maximum Operating Pressure'] = '8 bar AC/DC ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Size'] = '6,0 mm ';
attrValueMap['Exhaust Orifice Size'] = '1,6 mm ';
attrValueMap['Valve Type'] = '3/2 Way ';
attrValueMap['Maximum Operating Pressure'] = '3 bar AC/DC ';
attrValueMap['Flow Coefficient 1'] = '2,3 l/min ';
attrValueMap['Orifice Size'] = '2,5 mm ';
attrArray.push(attrValueMap);
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.....
Click here to view all product safety information.
Full Product Description
The Q Series Technopolymer Solenoid Valve range is a breakthrough product solutions making a new standard for the Beverage Dispense Industry.
This revolutionary range brings to the market a series of innovations and design advantages in the solenoid valve technologies for healthy fluids handling.
The new range responds to the unresolved needs of customers and relative industrial segment in terms of installation, maintenance, optimization of direct and indirect costs related to the life of the product.
Indeed, the concept itself of solenoid valve changes and evolves into a cartridge based system, patented by Parker, bringing exclusive benefits to the market like the zero tooling for installation, operational life and maintenance, disposability, unmatched uptime besides the outstanding reliability and life achievements which are intrinsic proprieties of Parker products.
Our technopolymer range is equipped with Parker Tracking System. Immediate traceability, docs availability, technical specs and contact points available at the point of installation expand our Customer Experience making such products a must have and game changing technology.