Pilot Operated Pressure Relief Valve, Subplate Mounting - Series R4V/R6V / R4V/R6V Proportional Pilot Operated Pressure Relief Valve, Subplate Mounting - Series R4V/R6V / R4V/R6V Proportional Pilot Operated Pressure Relief Valve, Subplate Mounting - Series R4V/R6V / R4V/R6V Proportional Pilot Operated Pressure Relief Valve, Subplate Mounting - Series R4V/R6V / R4V/R6V Proportional

Pilot Operated Pressure Relief Valve, Subplate Mounting - Series R4V/R6V / R4V/R6V Proportional

Parker pilot operated pressure relief valves for subplate mounting series R4V/R6V provide an outstanding constant pressure behaviour. Series R4V/R6V Proportional enables a continuous pressure adjustment by the additional proportional unit.

Technical Specifications

  • Maximum Operating Pressure: Port A, X 350; port B, Y 30, Port P, X 350; port T, Y 30 bar
  • Operation Type: Pilot
  • Maximum Flow Rate: N/A
  • Actuation Type: Manual, Solenoid
  • Weight: 2.7 to 9.2 kg Depending on Size and Configuration
  • Flow Rate: Depending on size, 90 - 650 L/min
  • Maximum Operating Temperature: 60 °C
  • Minimum Operating Temperature: -20 °C
  • Seal Material: NBR, FPM
  • Body Material: Cast iron
  • For Fluid Type: Hydraulic oil according to DIN 51524, Water glycol
  • Pressure Control Range: 105, 210, 350 bar
Safety Warning

Full Product Description

Well known as excellent pressure relief valves, Parker's series R4V/R6V and R4V/R6V Proportional for subplate mounting work stable across the whole pressure range and thus contribute to a smooth-running operation. Additionally they provide a wide range of options and connections for a versatile use in various applications.

Pilot operated pressure relief valves series R4V (DIN 24340 Form D) and R6V (DIN 24340 Form E) consist of a manually or a proportionally adjusted pilot stage and a seated type main stage. A vent function with a solenoid operated directional valve is available for circulation at minimum pressure. The optimum performance of the proportional version can be achieved in combination with the digital amplifier module PCD00A-400.

Markets:
• Industrial

Features/Benefits:
• Wide range of options – suitable for almost every application
• Outstanding constant pressure behavior – supports reliable operation
• Very good pressure/flow behavior – contributes to a high energy efficiency of the system
• Short delivery time – no warehousing necessary
• R4V/R6V Proportional: optimally suited to the digital amplifier module PCD00A-400
• Pilot operated with manual adjustment or with proportional solenoid
• 2 interfaces:
    - R4V Subplate ISO 6264 (DIN 24340 Form D) with VV01 vent valve
    - R6V Subplate ISO 6264 (DIN 24340 Form E) with CETOP 03 vent valve
• 3 pressure stages
• 3 adjustment modes:
    - hand knob
    - acorn nut with lead seal
    - cylinder lock
• Remote control via port X
• Mechanical maximum pressure adjustment (optional for R6V*P2)

Applications:
• Suitable for general hydraulic applications
• General presses
• Die cast

Function:
Series R4V/R6V
System pressure in port P is applied via the X gallery to the spring loaded cone in the pilot head. The pilot head controls the pressure in the Z area on top of the main cartridge which is additionally kept close by the main spring.
If the pilot pressure exceeds the setting pressure the pilot cone opens and thus limits the pilot pressure. When the system pressure exceeds the pilot pressure plus the spring force, the main cartridge opens to port T and limits the pressure in port P to the adjusted level.

Series R4V/R6V with vent function
Additionally to the relief function, a solenoid operated vent valve connects the Z area to tank. This allows oil circulation from P to T at minimum pressure drop. The vent valve can either be a standard CETOP 03 valve (R6V) or a sandwich unit (R4V). For both types the vent position can be either at the energized or de-energized solenoid.

Related Documents

×
Products Port Connection Seal Material Pressure Control Range Pressure Adjustment Control Type Drain Option Switching Option Input Voltage Additional Options Marking
016-87820-5 NG32 / CETOP 10 FPM 210 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
026-99959-G NG32 / CETOP 10 NBR 210 bar Acorn nut with lead seal Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V10-5333111G0RA1 NG32 / CETOP 10 NBR 210 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid activated, unpressurized circulation 12 VDC N/A Standard
R4V10-5333111GARA1 NG32 / CETOP 10 NBR 210 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid activated, unpressurized circulation 98 VDC N/A Standard
R4V10-53331A1 NG32 / CETOP 10 NBR 210 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
R4V10-53331A5 NG32 / CETOP 10 FPM 210 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
026-37251-G NG32 / CETOP 10 NBR 210 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
016-86058-0 NG32 / CETOP 10 NBR 210 bar Cylinder lock Drain line internal N/A N/A N/A Standard
026-71950-0 NG32 / CETOP 10 NBR 210 bar Cylinder lock Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
026-36455-H NG32 / CETOP 10 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
056-40034-H NG32 / CETOP 10 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
026-54074-H NG32 / CETOP 10 FPM 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R4V10-5351009G0QA5031 NG32 / CETOP 10 FPM 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
R4V10-5351009G0RA1 NG32 / CETOP 10 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 12 VDC N/A Standard
026-36457-B NG32 / CETOP 10 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R4V10-5351009W30A1031 NG32 / CETOP 10 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz Vent function with slow unloading, Code 031 Standard
026-99374-T NG32 / CETOP 10 FPM 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-36457-S NG32 / CETOP 10 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
026-36458-H NG32 / CETOP 10 NBR 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
026-56114-H NG32 / CETOP 10 FPM 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
026-36703-T NG32 / CETOP 10 NBR 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-36703-U NG32 / CETOP 10 NBR 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
016-84166-0 NG32 / CETOP 10 NBR 350 bar Hand knob Drain line internal N/A N/A N/A Standard
016-86256-0 NG32 / CETOP 10 FPM 350 bar Hand knob Drain line internal N/A N/A N/A Standard
026-99445-G NG32 / CETOP 10 NBR 350 bar Hand knob Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
026-46700-H NG32 / CETOP 10 NBR 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
026-46503-B NG32 / CETOP 10 NBR 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R4V10-5351109W30A1031 NG32 / CETOP 10 NBR 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz Vent function with slow unloading, Code 031 Standard
R4V10-5351109W31A1 NG32 / CETOP 10 NBR 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
056-40215-H NG32 / CETOP 10 NBR 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
056-40339-B NG32 / CETOP 10 NBR 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-99380-T NG32 / CETOP 10 FPM 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
016-87991-0 NG32 / CETOP 10 NBR 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
026-66104-G NG32 / CETOP 10 NBR 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
016-95779-5 NG32 / CETOP 10 FPM 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
026-36778-H NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
026-55348-H NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
026-36207-B NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-36207-S NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
026-52466-U NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz Vent function with slow unloading, Code 031 Standard
R4V10-5353009W52A1031 NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation N/A Vent function with slow unloading, Code 031 Standard
026-42950-H NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R4V10-5353011G0QA5 NG32 / CETOP 10 FPM 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R4V10-5353011W30A1 NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-36209-S NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
016-86201-0 NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
056-40548-G NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V10-5353111G0QA1 NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
016-95146-0 NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
026-65818-G NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R6V03-5931009G0QB5 NG10 / CETOP 05 FPM 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V03-5931009W30B1 NG10 / CETOP 05 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R6V03-5931009W30B1VFM NG10 / CETOP 05 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz Vent function with slow unloading, Code VFM Standard
R6V03-5931009W30B5 NG10 / CETOP 05 FPM 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R6V03-5931009W31B1 NG10 / CETOP 05 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
026-99902-H NG10 / CETOP 05 NBR 210 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R6V03-5931011W30B1 NG10 / CETOP 05 NBR 210 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-99668-S NG10 / CETOP 05 NBR 210 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
056-40454-0 NG10 / CETOP 05 NBR 210 bar Hand knob Drain line internal N/A N/A N/A Standard
R6V03-59310B5 NG10 / CETOP 05 FPM 210 bar Hand knob Drain line internal N/A N/A N/A Standard
R6V03-5931209G0QB1VFM NG10 / CETOP 05 NBR 210 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code VFM Standard
R6V03-5931211G0QB1 NG10 / CETOP 05 NBR 210 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R6V03-5933009G0QB1 NG10 / CETOP 05 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V03-5933009W30B1 NG10 / CETOP 05 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R6V03-5933009W31B1 NG10 / CETOP 05 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
R4V10-5311009G0QA1031 NG32 / CETOP 10 NBR 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
R4V10-5311009W31A1 NG32 / CETOP 10 NBR 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
026-46186-H NG32 / CETOP 10 NBR 105 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R4V10-5311011G0QA5 NG32 / CETOP 10 FPM 105 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R4V10-5311011W30A1 NG32 / CETOP 10 NBR 105 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
016-84127-0 NG32 / CETOP 10 NBR 105 bar Hand knob Drain line internal N/A N/A N/A Standard
016-88365-0 NG32 / CETOP 10 FPM 105 bar Hand knob Drain line internal N/A N/A N/A Standard
026-65715-H NG32 / CETOP 10 NBR 105 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R4V10-5311111W31A1 NG32 / CETOP 10 NBR 105 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
016-85680-0 NG32 / CETOP 10 NBR 105 bar Hand knob Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
R4V10-5313009G0QA1031 NG32 / CETOP 10 NBR 105 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
026-67789-T NG32 / CETOP 10 NBR 105 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz Vent function with slow unloading, Code 031 Standard
016-87512-0 NG32 / CETOP 10 NBR 105 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
016-86226-0 NG32 / CETOP 10 NBR 105 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
026-38876-G NG32 / CETOP 10 NBR 105 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
026-43044-H NG32 / CETOP 10 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
026-36822-H NG32 / CETOP 10 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
026-43044-A NG32 / CETOP 10 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 205 VDC N/A Standard
026-36408-B NG32 / CETOP 10 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-36408-U NG32 / CETOP 10 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
026-41638-H NG32 / CETOP 10 NBR 210 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
026-41638-G NG32 / CETOP 10 NBR 210 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 12 VDC N/A Standard
016-85564-0 NG32 / CETOP 10 NBR 210 bar Hand knob Drain line internal N/A N/A N/A Standard
016-86363-0 NG32 / CETOP 10 FPM 210 bar Hand knob Drain line internal N/A N/A N/A Standard
R4V10-53310P2G0RA1 NG32 / CETOP 10 NBR 210 bar Hand knob Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
026-38133-H NG32 / CETOP 10 NBR 210 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
026-36409-T NG32 / CETOP 10 NBR 210 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
016-88219-0 NG32 / CETOP 10 NBR 210 bar Hand knob Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
016-88219-5 NG32 / CETOP 10 FPM 210 bar Hand knob Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
026-65728-G NG32 / CETOP 10 NBR 210 bar Hand knob Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V10-5331209G0QA1 NG32 / CETOP 10 NBR 210 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
026-27888-0 NG32 / CETOP 10 NBR 210 bar Hand knob Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
026-27888-5 NG32 / CETOP 10 FPM 210 bar Hand knob Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
026-41229-H NG32 / CETOP 10 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
026-42002-H NG32 / CETOP 10 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
R4V10-5333009W31A1 NG32 / CETOP 10 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
R4V10-5333011G0QA1 NG32 / CETOP 10 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
016-87820-0 NG32 / CETOP 10 NBR 210 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
R4V10-5353209G0QA1 NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V03-5911009G0QB1 NG10 / CETOP 05 NBR 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC na Standard
R6V03-5911009G0QB1VFM NG10 / CETOP 05 NBR 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code VFM Standard
R6V03-5911009W30B1 NG10 / CETOP 05 NBR 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R6V03-59110B1 NG10 / CETOP 05 NBR 105 bar Hand knob Drain line internal N/A N/A N/A Standard
R6V03-59110B5 NG10 / CETOP 05 FPM 105 bar Hand knob Drain line internal N/A N/A N/A Standard
R6V03-5913009G0QB1 NG10 / CETOP 05 NBR 105 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V03-59130B1 NG10 / CETOP 05 NBR 105 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
R6V03-5913209G0QB1 NG10 / CETOP 05 NBR 105 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V03-5913211G0QB1 NG10 / CETOP 05 NBR 105 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R6V03-5913211W30B1 NG10 / CETOP 05 NBR 105 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R6V03-591P2P2G0RB1 NG10 / CETOP 05 NBR 105 bar Hexagon screw with lock nut Drain line external from valve body (Y-port = G 1/8) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R6V03-591P2PSG0RB1 NG10 / CETOP 05 NBR 105 bar Hexagon screw with lock nut Drain line external from valve body (Y-port = G 1/8) Without pressure adjustment 12 VDC N/A Standard
R6V03-5931009G0QB1 NG10 / CETOP 05 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
056-40057-H NG10 / CETOP 05 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code VFM Standard
026-96351-0 NG10 / CETOP 05 NBR 210 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
R6V03-5934009W30B1 NG10 / CETOP 05 NBR 210 bar Cylinder lock Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-99463-0 NG10 / CETOP 05 NBR 210 bar Hexagon screw with lock nut Drain line internal Without pressure adjustment 12 VDC N/A Standard
R6V03-593P2P2G0RB1 NG10 / CETOP 05 NBR 210 bar Hexagon screw with lock nut Drain line external from valve body (Y-port = G 1/8) With mechanical maximum pressure adjustment 12 VDC N/A Standard
026-99341-5 NG10 / CETOP 05 FPM 210 bar Hexagon screw with lock nut Drain line external from valve body (Y-port = G 1/8) Without pressure adjustment 12 VDC N/A Standard
026-99420-H NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V03-5951009G0QB1VFM NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code VFM Standard
R6V03-5951009G0QB5 NG10 / CETOP 05 FPM 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V03-5951009G0RB1 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 12 VDC N/A Standard
R6V03-5951009G0RB1VFM NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 12 VDC Vent function with slow unloading, Code VFM Standard
R6V03-5951009GAGB1 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 205 VDC N/A Standard
026-99394-0 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 98 VDC N/A Standard
026-99444-B NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R6V03-5951009W30B5 NG10 / CETOP 05 FPM 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-99444-S NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
R6V03-5951011G0QB1 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R6V03-5951011G0QB5 NG10 / CETOP 05 FPM 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R6V03-5951011GAGB1 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 205 VDC N/A Standard
026-99409-S NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
026-99440-0 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal N/A N/A N/A Standard
R6V03-59510B5 NG10 / CETOP 05 FPM 350 bar Hand knob Drain line internal N/A N/A N/A Standard
R6V03-5951209G0QB1 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V03-5951209GAGB1 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 205 VDC N/A Standard
R6V03-5951211G0QB1 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R6V03-59512B1 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
R6V03-5953009G0QB1 NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V03-5953009G0QB1VFM NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code VFM Standard
R6V03-5953009G0QB5VFM NG10 / CETOP 05 FPM 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code VFM Standard
R6V03-5953009G0RB1 NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 12 VDC N/A Standard
R6V03-5953009W31B1 NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
R6V03-5953011G0QB1 NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R6V03-59530B1 NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
R6V03-59530B5 NG10 / CETOP 05 FPM 350 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
026-95381-H NG25 / CETOP 08 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
056-40040-H NG25 / CETOP 08 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code VFM Standard
R6V06-5931009W30B1 NG25 / CETOP 08 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R6V06-5931009W30B1VFM NG25 / CETOP 08 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz Vent function with slow unloading, Code VFM Standard
R6V06-5931009W31B1 NG25 / CETOP 08 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
R6V06-5931009W31B1VFM NG25 / CETOP 08 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz Vent function with slow unloading, Code VFM Standard
026-99460-H NG25 / CETOP 08 NBR 210 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
026-36131-H NG10 / CETOP 05 NBR 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R4V03-5311009G0QA1031 NG10 / CETOP 05 NBR 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
R4V03-5311009G0QA5 NG10 / CETOP 05 FPM 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R4V03-5311009G0RA5 NG10 / CETOP 05 FPM 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 12 VDC N/A Standard
026-36133-B NG10 / CETOP 05 NBR 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R4V03-5311009W30A1031 NG10 / CETOP 05 NBR 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz Vent function with slow unloading, Code 031 Standard
026-36133-U NG10 / CETOP 05 NBR 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
R4V03-5311009W31A5 NG10 / CETOP 05 FPM 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
R4V03-5311011GARA1 NG10 / CETOP 05 NBR 105 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 98 VDC N/A Standard
016-84109-0 NG10 / CETOP 05 NBR 105 bar Hand knob Drain line internal N/A N/A N/A Standard
016-84111-0 NG10 / CETOP 05 FPM 105 bar Hand knob Drain line internal N/A N/A N/A Standard
R4V03-53110P2G0RA1 NG10 / CETOP 05 NBR 105 bar Hand knob Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V03-53110P2G0RA5 NG10 / CETOP 05 FPM 105 bar Hand knob Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
026-62222-H NG10 / CETOP 05 NBR 105 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R4V03-5311111G0QA1 NG10 / CETOP 05 NBR 105 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
016-81149-0 NG10 / CETOP 05 NBR 105 bar Hand knob Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
016-81149-5 NG10 / CETOP 05 FPM 105 bar Hand knob Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
026-66129-G NG10 / CETOP 05 NBR 105 bar Hand knob Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R6V03-5953209G0QB1 NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V03-5953209G0QB1VFM NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code VFM Standard
R6V03-5953211G0QB1 NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R6V03-5954011G0QB1 NG10 / CETOP 05 NBR 350 bar Cylinder lock Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R6V03-59542B1 NG10 / CETOP 05 NBR 350 bar Cylinder lock Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
R6V03-595P0P2G0RB1 NG10 / CETOP 05 NBR 350 bar Hexagon screw with lock nut Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
R6V03-595P0PSG0RB1 NG10 / CETOP 05 NBR 350 bar Hexagon screw with lock nut Drain line internal Without pressure adjustment 12 VDC N/A Standard
026-96360-0 NG10 / CETOP 05 NBR 350 bar Hexagon screw with lock nut Drain line external from valve body (Y-port = G 1/8) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R6V03-595P2P2G0RB5 NG10 / CETOP 05 FPM 350 bar Hexagon screw with lock nut Drain line external from valve body (Y-port = G 1/8) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R6V03-595P2PSG0RB5 NG10 / CETOP 05 FPM 350 bar Hexagon screw with lock nut Drain line external from valve body (Y-port = G 1/8) Without pressure adjustment 12 VDC N/A Standard
R6V06-5911009G0QB1 NG25 / CETOP 08 NBR 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V06-5911009G0QB1VFM NG25 / CETOP 08 NBR 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code VFM Standard
R6V06-5911009G0QB5VFM NG25 / CETOP 08 FPM 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code VFM Standard
R6V06-5911009W30B1VFM NG25 / CETOP 08 NBR 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz Vent function with slow unloading, Code VFM Standard
R6V06-5911009W31B1 NG25 / CETOP 08 NBR 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
R6V06-5911011G0QB1 NG25 / CETOP 08 NBR 105 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R6V06-59110B1 NG25 / CETOP 08 NBR 105 bar Hand knob Drain line internal N/A N/A N/A Standard
R6V06-59110B5 NG25 / CETOP 08 FPM 105 bar Hand knob Drain line internal N/A N/A N/A Standard
R6V06-5911209G0QB1VFM NG25 / CETOP 08 NBR 105 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code VFM Standard
026-95374-0 NG25 / CETOP 08 NBR 105 bar Hand knob Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
R6V06-59112B5 NG25 / CETOP 08 FPM 105 bar Hand knob Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
026-95376-0 NG25 / CETOP 08 NBR 105 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
R6V06-59140B1 NG25 / CETOP 08 NBR 105 bar Cylinder lock Drain line internal N/A N/A N/A Standard
R6V06-591P2P2G0RB5 NG25 / CETOP 08 FPM 105 bar Hexagon screw with lock nut Drain line external from valve body (Y-port = G 1/8) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R6V06-591P2PSG0RB1 NG25 / CETOP 08 NBR 105 bar Hexagon screw with lock nut Drain line external from valve body (Y-port = G 1/8) Without pressure adjustment 12 VDC N/A Standard
R4V03-53111P2G0RA5 NG10 / CETOP 05 FPM 105 bar Hand knob Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V03-53112A1 NG10 / CETOP 05 NBR 105 bar Hand knob Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
026-41092-H NG10 / CETOP 05 NBR 105 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
056-40203-H NG10 / CETOP 05 NBR 105 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
R4V03-5313009W30A1 NG10 / CETOP 05 NBR 105 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-43555-T NG10 / CETOP 05 NBR 105 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz Vent function with slow unloading, Code 031 Standard
026-36709-U NG10 / CETOP 05 NBR 105 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
016-84113-0 NG10 / CETOP 05 NBR 105 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
R4V03-53130A5 NG10 / CETOP 05 FPM 105 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
R4V03-53130P2G0RA1 NG10 / CETOP 05 NBR 105 bar Acorn nut with lead seal Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V03-53130P2G0RA5 NG10 / CETOP 05 FPM 105 bar Acorn nut with lead seal Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
026-99678-H NG10 / CETOP 05 NBR 105 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
016-85519-0 NG10 / CETOP 05 NBR 105 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
R4V03-53131P2G0RA1 NG10 / CETOP 05 NBR 105 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V03-53132A1 NG10 / CETOP 05 NBR 105 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
026-99718-H NG10 / CETOP 05 NBR 105 bar Cylinder lock Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
026-36134-H NG10 / CETOP 05 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
026-36135-H NG10 / CETOP 05 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
026-99903-H NG10 / CETOP 05 FPM 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R4V03-5331009GAGA1 NG10 / CETOP 05 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 205 VDC N/A Standard
026-36136-B NG10 / CETOP 05 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-36136-S NG10 / CETOP 05 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
026-42911-H NG10 / CETOP 05 NBR 210 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
026-99357-H NG10 / CETOP 05 FPM 210 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
026-56064-S NG10 / CETOP 05 NBR 210 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
016-84661-0 NG10 / CETOP 05 NBR 210 bar Hand knob Drain line internal N/A N/A N/A Standard
016-88346-0 NG10 / CETOP 05 FPM 210 bar Hand knob Drain line internal N/A N/A N/A Standard
026-65686-G NG10 / CETOP 05 NBR 210 bar Hand knob Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
026-52264-H NG10 / CETOP 05 NBR 210 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R4V03-5331109W30A1 NG10 / CETOP 05 NBR 210 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R4V03-5331109W31A1 NG10 / CETOP 05 NBR 210 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
R4V03-5331111G0QA1 NG10 / CETOP 05 NBR 210 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
056-40321-B NG10 / CETOP 05 NBR 210 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
016-87702-0 NG10 / CETOP 05 NBR 210 bar Hand knob Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
016-87702-5 NG10 / CETOP 05 FPM 210 bar Hand knob Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
026-66587-G NG10 / CETOP 05 NBR 210 bar Hand knob Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
026-30764-G NG10 / CETOP 05 NBR 210 bar Hand knob Drain line external from valve body (Y-port = G 1/8) With mechanical maximum pressure adjustment 12 VDC N/A Standard
026-36139-H NG10 / CETOP 05 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
026-36140-H NG10 / CETOP 05 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
R4V03-5333009GARA1 NG10 / CETOP 05 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 98 VDC N/A Standard
026-36141-B NG10 / CETOP 05 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-36142-T NG10 / CETOP 05 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz Vent function with slow unloading, Code 031 Standard
026-36141-S NG10 / CETOP 05 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
026-36142-U NG10 / CETOP 05 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz Vent function with slow unloading, Code 031 Standard
R4V03-5333011G0QA1 NG10 / CETOP 05 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
016-88400-0 NG10 / CETOP 05 NBR 210 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
016-88400-5 NG10 / CETOP 05 FPM 210 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
026-37997-G NG10 / CETOP 05 NBR 210 bar Acorn nut with lead seal Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
026-20679-0 NG10 / CETOP 05 NBR 210 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
026-65948-G NG10 / CETOP 05 NBR 210 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V03-53332P2G0RA1 NG10 / CETOP 05 NBR 210 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R6V06-5931011W31B1 NG25 / CETOP 08 NBR 210 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
026-42865-U NG25 / CETOP 08 NBR 105 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz Vent function with slow unloading, Code 031 Standard
026-95806-H NG25 / CETOP 08 NBR 105 bar Acorn nut with lead seal Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
016-84141-0 NG25 / CETOP 08 NBR 105 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
016-84141-5 NG25 / CETOP 08 FPM 105 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
056-40075-H NG25 / CETOP 08 FPM 105 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
026-56129-T NG25 / CETOP 08 NBR 105 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz Vent function with slow unloading, Code 031 Standard
026-42388-0 NG25 / CETOP 08 NBR 105 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
R4V06-53131A5 NG25 / CETOP 08 FPM 105 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
026-71038-G NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
056-40077-G NG25 / CETOP 08 FPM 105 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
056-40064-H NG25 / CETOP 08 FPM 105 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
026-36301-H NG25 / CETOP 08 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
026-36248-H NG25 / CETOP 08 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
R4V06-5331009GAGA1 NG25 / CETOP 08 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 205 VDC N/A Standard
R4V06-5331009GARA1 NG25 / CETOP 08 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 98 VDC N/A Standard
026-36357-B NG25 / CETOP 08 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R4V06-5331009W30A5 NG25 / CETOP 08 FPM 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-36357-U NG25 / CETOP 08 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
026-99101-U NG25 / CETOP 08 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz Vent function with slow unloading, Code 031 Standard
026-36358-H NG25 / CETOP 08 NBR 210 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
026-95352-0 NG25 / CETOP 08 NBR 210 bar Hand knob Drain line internal N/A N/A N/A Standard
R6V06-59310B5 NG25 / CETOP 08 FPM 210 bar Hand knob Drain line internal N/A N/A N/A Standard
R6V06-5931209G0QB5 NG25 / CETOP 08 FPM 210 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V06-5931211GARB1 NG25 / CETOP 08 NBR 210 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid activated, unpressurized circulation 98 VDC N/A Standard
R6V06-5931211W31B1 NG25 / CETOP 08 NBR 210 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
R6V06-59312B1 NG25 / CETOP 08 NBR 210 bar Hand knob Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
R6V06-5933009G0QB1VFM NG25 / CETOP 08 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code VFM Standard
R6V06-5933009G0QB5VFM NG25 / CETOP 08 FPM 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code VFM Standard
026-95377-0 NG25 / CETOP 08 NBR 210 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
R6V06-5933209G0QB1 NG25 / CETOP 08 NBR 210 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V06-59332B1 NG25 / CETOP 08 NBR 210 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
R6V06-5934009G0QB1 NG25 / CETOP 08 NBR 210 bar Cylinder lock Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V06-59340B1 NG25 / CETOP 08 NBR 210 bar Cylinder lock Drain line internal N/A N/A N/A Standard
R6V06-593P0PSG0RB1 NG25 / CETOP 08 NBR 210 bar Hexagon screw with lock nut Drain line internal Without pressure adjustment 12 VDC N/A Standard
R6V06-593P2PSG0RB1 NG25 / CETOP 08 NBR 210 bar Hexagon screw with lock nut Drain line external from valve body (Y-port = G 1/8) Without pressure adjustment 12 VDC N/A Standard
026-95384-H NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
026-99354-H NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code VFM Standard
R6V06-5951009G0QB5 NG25 / CETOP 08 FPM 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
026-99392-0 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 98 VDC N/A Standard
026-95384-B NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-95384-S NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
026-99469-H NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R6V06-5951011G0QB5 NG25 / CETOP 08 FPM 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R6V06-5951011GARB1 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 98 VDC N/A Standard
R6V06-5951011W30B1 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-95383-0 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal N/A N/A N/A Standard
016-86996-0 NG25 / CETOP 08 FPM 350 bar Hand knob Drain line internal N/A N/A N/A Standard
R4V06-53510P2G0RA1 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V06-53510P2G0RA5 NG25 / CETOP 08 FPM 350 bar Hand knob Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
026-41330-H NG25 / CETOP 08 NBR 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R4V06-5351109GARA1 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 98 VDC N/A Standard
R4V06-5351111G0QA1 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R4V06-53511A1 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
R4V06-53511A5 NG25 / CETOP 08 FPM 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
026-57890-G NG25 / CETOP 08 NBR 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V06-53511P2G0RA5 NG25 / CETOP 08 FPM 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V06-5351211G0QA1 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
026-20087-0 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
026-36336-H NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
026-47988-H NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
R4V06-5353009G0QA5031 NG25 / CETOP 08 FPM 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
R4V06-5353009G0RA1 NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 12 VDC N/A Standard
026-95383-5 NG25 / CETOP 08 FPM 350 bar Hand knob Drain line internal N/A N/A N/A Standard
026-99132-H NG25 / CETOP 08 NBR 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V06-5951209G0QB1VFM NG25 / CETOP 08 NBR 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code VFM Standard
R6V06-5951209G0QB5 NG25 / CETOP 08 FPM 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V06-5951211G0QB1 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R6V06-5951211GARB1 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid activated, unpressurized circulation 98 VDC N/A Standard
R6V06-5951211W31B1 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
R6V06-59512B1 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
R6V06-59512B5 NG25 / CETOP 08 FPM 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
026-95361-H NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V06-5953009G0QB1VFM NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code VFM Standard
R6V06-5953009W31B1 NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
R6V06-5953011G0QB1 NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
026-95378-0 NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
R6V06-5953209G0QB1 NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
026-99336-H NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
026-99335-0 NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
R6V06-59532B5 NG25 / CETOP 08 FPM 350 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
R6V06-5954011G0QB1 NG25 / CETOP 08 NBR 350 bar Cylinder lock Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R6V06-595P0P2G0RB1 NG25 / CETOP 08 NBR 350 bar Hexagon screw with lock nut Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
R6V06-595P0P2G0RB5 NG25 / CETOP 08 FPM 350 bar Hexagon screw with lock nut Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
R6V06-595P2P2G0RB1 NG25 / CETOP 08 NBR 350 bar Hexagon screw with lock nut Drain line external from valve body (Y-port = G 1/8) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R6V10-5911009G0QB1 NG32 / CETOP 10 NBR 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V10-5911011G0QB1 NG32 / CETOP 10 NBR 105 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R6V10-59110B1 NG32 / CETOP 10 NBR 105 bar Hand knob Drain line internal N/A N/A N/A Standard
R6V10-5911209G0QB1 NG32 / CETOP 10 NBR 105 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
056-40422-0 NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 98 VDC N/A Standard
026-36337-B NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-43556-T NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz Vent function with slow unloading, Code 031 Standard
026-36337-U NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
026-43556-U NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz Vent function with slow unloading, Code 031 Standard
026-46368-H NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
026-99134-H NG25 / CETOP 08 FPM 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
016-84149-0 NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
016-84149-5 NG25 / CETOP 08 FPM 350 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
R4V06-53530P2G0RA1 NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
026-41565-H NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
016-81042-0 NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
026-65725-G NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V06-5354009G0QA1 NG25 / CETOP 08 NBR 350 bar Cylinder lock Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R4V06-53541A1 NG25 / CETOP 08 NBR 350 bar Cylinder lock Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
026-36843-H NG32 / CETOP 10 NBR 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V10-5913009G0QB1 NG32 / CETOP 10 NBR 105 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V10-5913009W31B1 NG32 / CETOP 10 NBR 105 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
R6V10-5931009G0QB1 NG32 / CETOP 10 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V10-5931009W30B1VFM NG32 / CETOP 10 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz Vent function with slow unloading, Code VFM Standard
R6V10-5931009W31B1 NG32 / CETOP 10 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
R6V10-5931011G0QB1 NG32 / CETOP 10 NBR 210 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R6V10-5931011W30B1 NG32 / CETOP 10 NBR 210 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R6V10-59310B1 NG32 / CETOP 10 NBR 210 bar Hand knob Drain line internal N/A N/A N/A Standard
R6V10-5931209G0QB1 NG32 / CETOP 10 NBR 210 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V10-5933009G0QB1VFM NG32 / CETOP 10 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code VFM Standard
R6V10-5933209G0QB1 NG32 / CETOP 10 NBR 210 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V10-5933211G0QB1 NG32 / CETOP 10 NBR 210 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R6V10-59342B5 NG32 / CETOP 10 FPM 210 bar Cylinder lock Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
R6V10-593P2P2G0RB1 NG32 / CETOP 10 NBR 210 bar Hexagon screw with lock nut Drain line external from valve body (Y-port = G 1/8) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R6V10-5951009G0QB1 NG32 / CETOP 10 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V10-5951009W30B1 NG32 / CETOP 10 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R6V10-5951009W31B1 NG32 / CETOP 10 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
R6V10-5951011G0QB1 NG32 / CETOP 10 NBR 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
026-96361-0 NG32 / CETOP 10 NBR 350 bar Hand knob Drain line internal N/A N/A N/A Standard
026-96361-5 NG32 / CETOP 10 FPM 350 bar Hand knob Drain line internal N/A N/A N/A Standard
026-42451-H NG10 / CETOP 05 NBR 210 bar Cylinder lock Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R4V03-5334009G0QA1031 NG10 / CETOP 05 NBR 210 bar Cylinder lock Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
R4V03-53340A1 NG10 / CETOP 05 NBR 210 bar Cylinder lock Drain line internal N/A N/A N/A Standard
026-36143-H NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R4V03-5351009G0QA1031 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
026-35975-H NG10 / CETOP 05 FPM 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
026-36143-A NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 205 VDC N/A Standard
R4V03-5351009GARA1 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 98 VDC N/A Standard
026-36146-B NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-36146-S NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
R4V03-5351009W31A1031 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz Vent function with slow unloading, Code 031 Standard
026-36147-H NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
026-99113-H NG10 / CETOP 05 FPM 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
026-36147-A NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 205 VDC N/A Standard
056-40350-0 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 98 VDC N/A Standard
026-41013-T NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-41013-U NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
016-84114-0 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal N/A N/A N/A Standard
016-84115-0 NG10 / CETOP 05 FPM 350 bar Hand knob Drain line internal N/A N/A N/A Standard
026-39566-G NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
026-41245-H NG10 / CETOP 05 NBR 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
056-40450-H NG10 / CETOP 05 NBR 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
R4V03-5351109G0QA5 NG10 / CETOP 05 FPM 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
056-40351-0 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 98 VDC N/A Standard
R4V03-5351109W30A1 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R4V03-5351109W31A1 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
056-40404-H NG10 / CETOP 05 NBR 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
016-84553-0 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
016-86302-0 NG10 / CETOP 05 FPM 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
026-65187-G NG10 / CETOP 05 NBR 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V03-53511P2G0RA5 NG10 / CETOP 05 FPM 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
026-41685-B NG10 / CETOP 05 NBR 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
016-91544-0 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
026-62147-G NG10 / CETOP 05 NBR 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) With mechanical maximum pressure adjustment 12 VDC N/A Standard
056-40065-G NG10 / CETOP 05 FPM 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) With mechanical maximum pressure adjustment 12 VDC N/A Standard
026-36777-H NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
026-41722-H NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
R4V03-5353009G0QA5 NG10 / CETOP 05 FPM 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R4V03-5353009GARA1 NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 98 VDC N/A Standard
026-36641-B NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-42020-T NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz Vent function with slow unloading, Code 031 Standard
026-36641-U NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
026-42020-U NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz Vent function with slow unloading, Code 031 Standard
026-36779-H NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
026-99260-H NG10 / CETOP 05 FPM 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
016-85108-0 NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
016-85108-5 NG10 / CETOP 05 FPM 350 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
R4V03-53530P2G0RA1 NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V03-53530P2G0RA5 NG10 / CETOP 05 FPM 350 bar Acorn nut with lead seal Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
026-41142-H NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
056-40074-H NG10 / CETOP 05 FPM 350 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
R4V03-5353109W30A1 NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-95457-T NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz Vent function with slow unloading, Code 031 Standard
016-85518-0 NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
026-65947-G NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
056-40076-G NG10 / CETOP 05 FPM 350 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V03-5353209G0QA1 NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
056-40063-H NG10 / CETOP 05 FPM 350 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
026-48287-0 NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
R4V03-53532P2G0RA1 NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) With mechanical maximum pressure adjustment 12 VDC N/A Standard
026-70269-H NG10 / CETOP 05 NBR 350 bar Cylinder lock Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
016-86301-0 NG10 / CETOP 05 NBR 350 bar Cylinder lock Drain line internal N/A N/A N/A Standard
026-36245-H NG25 / CETOP 08 NBR 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R4V06-5311009G0QA5 NG25 / CETOP 08 FPM 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
026-36354-B NG25 / CETOP 08 NBR 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R4V06-5311009W30A5 NG25 / CETOP 08 FPM 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-36354-U NG25 / CETOP 08 NBR 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
026-42330-H NG25 / CETOP 08 NBR 105 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
016-84137-0 NG25 / CETOP 08 NBR 105 bar Hand knob Drain line internal N/A N/A N/A Standard
016-84137-5 NG25 / CETOP 08 FPM 105 bar Hand knob Drain line internal N/A N/A N/A Standard
R4V06-53110P2G0RA5 NG25 / CETOP 08 FPM 105 bar Hand knob Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
026-96960-H NG32 / CETOP 10 NBR 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V10-5951209G0QB5 NG32 / CETOP 10 FPM 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
056-40273-B NG32 / CETOP 10 NBR 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R6V10-59512B1 NG32 / CETOP 10 NBR 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
R6V10-5953009G0QB1 NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V10-5953009G0QB1VFM NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code VFM Standard
R6V10-5953009W31B1 NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
R6V10-59530B1 NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
R6V10-5953209G0QB1 NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V10-5953211G0QB1 NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
026-99422-H NG32 / CETOP 10 NBR 350 bar Cylinder lock Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R6V10-59540B1 NG32 / CETOP 10 NBR 350 bar Cylinder lock Drain line internal N/A N/A N/A Standard
R6V10-595P0P2G0RB5 NG32 / CETOP 10 FPM 350 bar Hexagon screw with lock nut Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
R6V10-595P2P2G0RB1 NG32 / CETOP 10 NBR 350 bar Hexagon screw with lock nut Drain line external from valve body (Y-port = G 1/8) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V06-5311109G0QA1 NG25 / CETOP 08 NBR 105 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R4V06-5311109W30A1 NG25 / CETOP 08 NBR 105 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
016-81049-0 NG25 / CETOP 08 NBR 105 bar Hand knob Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
016-81049-5 NG25 / CETOP 08 FPM 105 bar Hand knob Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
R4V06-53111P2G0RA5 NG25 / CETOP 08 FPM 105 bar Hand knob Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V06-5311209G0QA1 NG25 / CETOP 08 NBR 105 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
026-43571-0 NG25 / CETOP 08 NBR 105 bar Hand knob Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
056-40066-G NG25 / CETOP 08 FPM 105 bar Hand knob Drain line external from valve body (Y-port = G 1/8) With mechanical maximum pressure adjustment 12 VDC N/A Standard
026-36355-H NG25 / CETOP 08 NBR 105 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
026-65113-H NG25 / CETOP 08 NBR 105 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
026-36356-B NG25 / CETOP 08 NBR 105 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-42865-T NG25 / CETOP 08 NBR 105 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz Vent function with slow unloading, Code 031 Standard
R4V06-5331011W30A1 NG25 / CETOP 08 NBR 210 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R4V06-5331011W31A1 NG25 / CETOP 08 NBR 210 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
016-85200-0 NG25 / CETOP 08 NBR 210 bar Hand knob Drain line internal N/A N/A N/A Standard
016-88389-0 NG25 / CETOP 08 FPM 210 bar Hand knob Drain line internal N/A N/A N/A Standard
R4V06-53310P2G0RA1 NG25 / CETOP 08 NBR 210 bar Hand knob Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V06-5331109G0QA1 NG25 / CETOP 08 NBR 210 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
016-87653-0 NG25 / CETOP 08 NBR 210 bar Hand knob Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
016-87653-5 NG25 / CETOP 08 FPM 210 bar Hand knob Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
026-65827-G NG25 / CETOP 08 NBR 210 bar Hand knob Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
016-87545-0 NG25 / CETOP 08 NBR 210 bar Hand knob Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
R4V06-53312A5 NG25 / CETOP 08 FPM 210 bar Hand knob Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
026-36360-H NG25 / CETOP 08 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
026-36361-H NG25 / CETOP 08 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
026-36362-B NG25 / CETOP 08 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-42542-T NG25 / CETOP 08 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz Vent function with slow unloading, Code 031 Standard
026-36362-U NG25 / CETOP 08 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
056-40464-H NG25 / CETOP 08 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
016-87819-0 NG25 / CETOP 08 NBR 210 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
016-87819-5 NG25 / CETOP 08 FPM 210 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
R4V06-53330P2G0RA1 NG25 / CETOP 08 NBR 210 bar Acorn nut with lead seal Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
026-20276-0 NG25 / CETOP 08 NBR 210 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
R4V06-53331A5 NG25 / CETOP 08 FPM 210 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
026-66619-G NG25 / CETOP 08 NBR 210 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V06-53332P2G0RA1 NG25 / CETOP 08 NBR 210 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V06-53340A1 NG25 / CETOP 08 NBR 210 bar Cylinder lock Drain line internal N/A N/A N/A Standard
R4V06-53340A5 NG25 / CETOP 08 FPM 210 bar Cylinder lock Drain line internal N/A N/A N/A Standard
026-36246-H NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
026-36821-H NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
R4V06-5351009G0RA1 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 12 VDC N/A Standard
056-40245-0 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 98 VDC N/A Standard
026-36298-B NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-36298-S NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
026-36776-H NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
026-99114-H NG25 / CETOP 08 FPM 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R4V06-5351011G0RA1 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 12 VDC N/A Standard
R4V06-5351011GAGA1 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 205 VDC N/A Standard
R4V06-5351011GARA1 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 98 VDC N/A Standard
026-36364-T NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
026-36364-U NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
016-84142-0 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal N/A N/A N/A Standard
R4V06-53331P2G0RA5 NG25 / CETOP 08 FPM 210 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V03-53310P2G0RA1 NG10 / CETOP 05 NBR 210 bar Hand knob Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V03-53510P2G0RA5 NG10 / CETOP 05 FPM 350 bar Hand knob Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V03-53511P2G0RA1 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R6V10-595P2PSG0RB5 NG32 / CETOP 10 FPM 350 bar Hexagon screw with lock nut Drain line external from valve body (Y-port = G 1/8) Without pressure adjustment 12 VDC N/A Standard
R6V03-595P0P2G0RB5 NG10 / CETOP 05 FPM 350 bar Hexagon screw with lock nut Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
R6V06-593P0P2G0RB1 NG25 / CETOP 08 NBR 210 bar Hexagon screw with lock nut Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V06-5311009G0QA1031 NG25 / CETOP 08 NBR 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
R4V06-5333009W30A5 NG25 / CETOP 08 FPM 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R4V06-53341A1 NG25 / CETOP 08 NBR 210 bar Cylinder lock Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
R4V06-5351009GAGA1 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 205 VDC N/A Standard
R4V06-5351009W30A5 NG25 / CETOP 08 FPM 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
016-81038-0 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
R4V06-53531A5 NG25 / CETOP 08 FPM 350 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
R4V06-59112P2G0RA1 NG25 / CETOP 08 NBR 105 bar Hand knob Drain line external from valve body (Y-port = G 1/8) With mechanical maximum pressure adjustment 12 VDC N/A Standard
026-62268-G NG25 / CETOP 08 NBR 210 bar Hand knob Drain line external from valve body (Y-port = G 1/8) With mechanical maximum pressure adjustment 12 VDC N/A Standard
026-65964-G NG25 / CETOP 08 NBR 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V10-5311109G0QA1 NG32 / CETOP 10 NBR 105 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R4V10-5311109W30A1 NG32 / CETOP 10 NBR 105 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R4V10-53111A5 NG32 / CETOP 10 FPM 105 bar Hand knob Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
R4V10-5333009W30A1 NG32 / CETOP 10 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R4V10-5333109GAGA1 NG32 / CETOP 10 NBR 210 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 205 VDC N/A Standard
R4V10-53511A5 NG32 / CETOP 10 FPM 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
R6V03-5914011G0QB1 NG10 / CETOP 05 NBR 105 bar Cylinder lock Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R6V03-5931009W31B1VFM NG10 / CETOP 05 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz Vent function with slow unloading, Code VFM Standard
R6V03-5933009GARB1 NG10 / CETOP 05 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 98 VDC N/A Standard
R6V03-59330B5 NG10 / CETOP 05 FPM 210 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
R6V03-5951011G0RB1 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 12 VDC N/A Standard
R4V03-5311009W30A5 NG10 / CETOP 05 FPM 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R4V03-53130P2G0QA1 NG10 / CETOP 05 NBR 105 bar Acorn nut with lead seal Drain line internal With mechanical maximum pressure adjustment 24 VDC N/A Standard
R4V03-5333009G0QA5 NG10 / CETOP 05 FPM 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
026-37997-H NG10 / CETOP 05 NBR 210 bar Acorn nut with lead seal Drain line internal With mechanical maximum pressure adjustment 24 VDC N/A Standard
R6V10-595P0P2G0RB1 NG32 / CETOP 10 NBR 350 bar Hexagon screw with lock nut Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V03-53331P2G0RA5 NG10 / CETOP 05 FPM 210 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V03-5334009G0QA5 NG10 / CETOP 05 FPM 210 bar Cylinder lock Drain line internal N/A 24 VDC N/A Standard
R4V03-5351009W30A1031 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz Vent function with slow unloading, Code 031 Standard
R4V03-5354109W30A5 NG10 / CETOP 05 NBR 350 bar Cylinder lock Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R6V03-5931209W30B1 NG10 / CETOP 05 NBR 210 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R6V03-5931211W30B1 NG10 / CETOP 05 NBR 210 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R6V06-5931009G0QB5 NG25 / CETOP 08 FPM 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V06-5951009W30B5 NG25 / CETOP 08 FPM 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R6V06-5951009W31B1VFM NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz Vent function with slow unloading, Code VFM Standard
R4V06-53131P2G0RA5 NG25 / CETOP 08 FPM 105 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R4V10-53510P2G0RA5 NG32 / CETOP 10 FPM 350 bar Hand knob Drain line internal With mechanical maximum pressure adjustment 12 VDC N/A Standard
R6V03-595P2PSG0RB1 NG10 / CETOP 05 NBR 350 bar Hexagon screw with lock nut Drain line external from valve body (Y-port = G 1/8) Without pressure adjustment 12 VDC N/A Standard
R6V06-595P2PSG0RB1 NG25 / CETOP 08 NBR 350 bar Hexagon screw with lock nut Drain line external from valve body (Y-port = G 1/8) Without pressure adjustment 12 VDC N/A Standard
R4V06-53511A5 NG25 / CETOP 08 FPM 350 bar Hand knob Drain line external from subplate (Y port in mounting pattern) N/A N/A N/A Standard
R4V03-5351009G0RA1 NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 12 VDC N/A Standard
R4V06-5311111G0QA1 NG25 / CETOP 08 NBR 105 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R4V06-5331009G0QA5 NG25 / CETOP 08 FPM 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R4V06-5351009GARA1031 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 98 VDC Vent function with slow unloading, Code 031 Standard
R4V06-5353109W30A1 NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R4V10-5311009W30A1 NG32 / CETOP 10 NBR 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R4V10-5333109W30A1 NG32 / CETOP 10 NBR 210 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R4V10-5353109G0QA1 NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R4V03-5331109G0QA1031 NG10 / CETOP 05 NBR 210 bar Hand knob Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 12 VDC Vent function with slow unloading, Code 031 Standard
R4V03-5333011GAGA1 NG10 / CETOP 05 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid activated, unpressurized circulation 205 VDC N/A Standard
R4V03-5353009G0QA5031 NG10 / CETOP 05 FPM 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
R4V03-5353009GAGA1 NG10 / CETOP 05 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 205 VDC N/A Standard
R4V06-5313009G0QA5031 NG25 / CETOP 08 FPM 105 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
R4V06-5353009GAGA1 NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 205 VDC N/A Standard
R4V06-53540A1 NG25 / CETOP 08 NBR 350 bar Cylinder lock Drain line internal na N/A N/A Standard
R4V06-53540A5 NG25 / CETOP 08 FPM 350 bar Cylinder lock Drain line internal na N/A N/A Standard
R4V10-5313109G0QA1031 NG32 / CETOP 10 NBR 105 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code 031 Standard
R4V10-5331009GARA5 NG32 / CETOP 10 FPM 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 98 VDC N/A Standard
R4V10-5331011GAGA1 NG32 / CETOP 10 NBR 210 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 205 VDC N/A Standard
R4V10-53310P2G0RA5 NG32 / CETOP 10 FPM 210 bar Hand knob Drain line internal With mechanical maximum pressure adjustment12 (DC) 12 VDC N/A Standard
R4V10-5353009GAGA1 NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 205 VDC N/A Standard
R6V03-5911209G0QB1 NG10 / CETOP 05 NBR 105 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V03-5911211G0QB1 NG10 / CETOP 05 NBR 105 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R6V03-5933011W31B1 NG10 / CETOP 05 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
R6V03-5951009W31B1VFM NG10 / CETOP 05 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz Vent function with slow unloading, Code VFM Standard
R6V03-5954009G0QB1 NG10 / CETOP 05 NBR 350 bar Cylinder lock Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V06-5911009W30B1 NG25 / CETOP 08 NBR 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R6V06-5913009G0QB1 NG25 / CETOP 08 NBR 105 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V06-5953009G0QB5 NG25 / CETOP 08 FPM 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V06-5953009W30B1 NG25 / CETOP 08 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R6V10-5953009G0QB5 NG32 / CETOP 10 FPM 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R4V06-53131P2G0RA1 NG25 / CETOP 08 NBR 105 bar Acorn nut with lead seal Drain line external from subplate (Y port in mounting pattern) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R6V06-5951209W31B1 NG25 / CETOP 08 NBR 350 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
R6V10-5951009G0QB1VFM NG32 / CETOP 10 NBR 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code VFM Standard
R4V10-5311009G0QA5 NG32 / CETOP 10 FPM 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V03-5913209G0QB1VFM NG10 / CETOP 05 NBR 105 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code VFM Standard
R6V03-59130B5 NG10 / CETOP 05 FPM 105 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
R6V03-59112B1 NG10 / CETOP 05 NBR 105 bar Hand knob Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
R4V10-5354011G0QA1 NG32 / CETOP 10 NBR 350 bar Cylinder lock Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R6V10-5931009G0QB1VFM NG32 / CETOP 10 NBR 210 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC Vent function with slow unloading, Code VFM Standard
R6V10-59132B1 NG32 / CETOP 10 NBR 105 bar Acorn nut with lead seal Drain line external from valve body (Y-port = G 1/8) N/A N/A N/A Standard
R6V10-5911009W30B1 NG32 / CETOP 10 NBR 105 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R6V06-593P2P2G0RB1 NG25 / CETOP 08 NBR 210 bar Hexagon screw with lock nut Drain line external from valve body (Y-port = G 1/8) With mechanical maximum pressure adjustment 12 VDC N/A Standard
R6V06-5933009G0QB1 NG25 / CETOP 08 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V06-5931211W30B1 NG25 / CETOP 08 NBR 210 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R6V06-5931209W31B1 NG25 / CETOP 08 NBR 210 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 230/240 VAC, 50/60 Hz N/A Standard
R6V06-5931209W30B1 NG25 / CETOP 08 NBR 210 bar Hand knob Drain line external from valve body (Y-port = G 1/8) Vent function: solenoid not activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R4V10-53530A5 NG32 / CETOP 10 FPM 350 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
R4V03-5333011G0QA5 NG10 / CETOP 05 FPM 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R6V06-5931011W30B1 NG25 / CETOP 08 NBR 210 bar Hand knob Drain line internal Vent function: solenoid activated, unpressurized circulation 110/120 VAC, 50/60 Hz N/A Standard
R6V06-59130B5 NG25 / CETOP 08 FPM 105 bar Acorn nut with lead seal Drain line internal N/A N/A N/A Standard
R6V03-5953009G0QB5 NG10 / CETOP 05 FPM 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R4V06-5351009G0QA5 NG25 / CETOP 08 FPM 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R4V10-5353009GARA1 NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 98 VDC N/A Standard
R6V10-5954009G0QB5 NG32 / CETOP 10 FPM 350 bar Cylinder lock Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R4V10-5333011GARA1 NG32 / CETOP 10 NBR 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid activated, unpressurized circulation 98 VDC N/A Standard
R4V10-5333009G0QA5 NG32 / CETOP 10 FPM 210 bar Acorn nut with lead seal Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R4V06-53140A1 NG25 / CETOP 08 NBR 105 bar Cylinder lock Drain line internal N/A N/A N/A Standard
R6V10-5951009G0QB5 NG32 / CETOP 10 FPM 350 bar Hand knob Drain line internal Vent function: solenoid not activated, unpressurized circulation 24 VDC N/A Standard
R6V10-5953011G0QB1 NG32 / CETOP 10 NBR 350 bar Acorn nut with lead seal Drain line internal Vent function: solenoid activated, unpressurized circulation 24 VDC N/A Standard
R6V065951009G0QB1VFMXG341 Proprietary Item

687466
687478