Pilot Operated Pressure Relief Valve, SAE Flange - Series R5V / R5V*P2 | Product Series

Filter by

    No filters selected

Actuation Type

Pressure Adjustment Control Type

Drain Option

Switching Option

Signal Input

Seal Material

Additional Options

Port Connection

Port Size

Body Type

Pressure Control Range

Get your Parker account Today!

Create one account to manage everything you do with Parker, from your shopping preferences to your application access.


LOADING IMAGES
Pilot Operated Pressure Relief Valve, SAE Flange - Series R5V / R5V*P2 Pilot Operated Pressure Relief Valve, SAE Flange - Series R5V / R5V*P2 Pilot Operated Pressure Relief Valve, SAE Flange - Series R5V / R5V*P2 Pilot Operated Pressure Relief Valve, SAE Flange - Series R5V / R5V*P2

Pilot Operated Pressure Relief Valve, SAE Flange - Series R5V / R5V*P2

Parker pilot operated pressure relief valves series R5V and R5V*P2 provide an outstanding constant pressure behaviour. The SAE flanges allow to mount the valves directly on the flanges of pumps or actuators to achieve a very compact design.

Technical Specifications

  • Actuation Type: Manual, solenoid
  • Operation Type: Pilot
  • Flow Rate: Depending on size, 90 - 600 L/min
  • Weight: 3.6 to 9.8 kg Depending on Size and Configuration
  • Maximum Flow Rate: N/A L/min
  • Maximum Operating Pressure: Depending on size, 210 - 350 bar
  • Maximum Operating Temperature: 60 °C
  • Minimum Operating Temperature: -20 °C
  • Seal Material: NBR, FPM
  • Body Material: Cast iron
  • For Fluid Type: Hydraulic oil according to DIN 51524, Water glycol
  • Pressure Control Range: 105, 210, 350 bar
  • Product Series: Pressure valve
  • Mounting Type: Flanged according to SAE61 and SAE62, depending on size
Safety Warning

Full Product Description

Well known as excellent pressure relief valves, Parker's series R5V and R5V*P2 work stable across the whole pressure range and thus contribute to a smooth-running operation. Additionally they provide a wide range of options and connections for a versatile use in various applications. R5V and R5V*P2 are part of the Parker valve range with SAE flanges which is unique in its variety.




Their design is similar to the subplate mounted R4V series. They provide an outstanding constant pressure behaviour. The SAE flanges allow to mount the valves directly on the outlet flanges of pumps or inlet flanges of actuators to achieve a very compact design.




Series R5V*P2 with additional proportional unit between the mechanical pilot valve and the main stage ensures continuous pressure adjustment. The optimum performance can be achieved in combination with the digital amplifier module PCD00A-400.




Market:

• Industrial




Features/Benefits:

• Wide range of options – suitable for almost every application

• Outstanding constant pressure behavior – supports reliable operation

• Very good pressure/flow behavior – contributes to a high energy efficiency of the system

• SAE flange - enables compact design

• Short delivery time – no warehousing necessary

• Pilot operated with manual adjustment

• R5V with 3-port body: 4 sizes (SAE ¾", 1", 1¼", 1½")

• 3 pressure stages

• 3 adjustment modes:

     - hand knob

     - acorn nut with lead seal

     - cylinder lock

• With optional vent function




Deviating Features/Benefits series R5V*P2:

• Continuous adjustment by proportional solenoid

• With mechanical maximum pressure adjustment

• Optimally suited to the digital amplifier module PCD00A-400




Applications:

• Suitable for general hydraulic applications




Note: R5V with 2-port body is not longer available from Parker, please refer to the recommended products for a replacement.

Related Documents

×
Products Actuation Type Pressure Adjustment Control Type Drain Option Switching Option Signal Input Seal Material Additional Options Port Connection Port Size Body Type Pressure Control Range
R5V08-59336A1152 Manually Acorn nut with lead seal Drain line external from Y1-port N/A N/A NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-75911-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
026-99947-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-6931209W30A1008 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR Vent function with slow unloading SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
026-99353-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-5731209G0QA1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 3/4 SAE61 2-port, Y1 = G 1/4 210 BAR
R5V08-6951211G0QA1152 Manually Hand knob Drain line internal Solenoid activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-4931209G0QA1152 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-49312P2G0RA1 Proportional Hand knob Drain line internal N/A 12 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-6953609G0QA1152 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-5931209G0QA1008 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-69516P2G0RA1 Proportional Hand knob Drain line external from Y1-port N/A 12 VDC NBR N/A SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-6953209G0QA5152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM 3-port body with metric threads SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
026-66356-U Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 230/240 VAC, 50/60 Hz NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-96802-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-6931209G0QA1152 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
026-52089-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-69512A5070 Manually Hand knob Drain line internal N/A N/A FPM Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
056-40097-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-5931209G0QA5 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-69116P2G0RA1 Proportional Hand knob Drain line external from Y1-port N/A 12 VDC NBR N/A SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 105 BAR
026-66455-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-55533-G Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 12 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-4931209GAGA1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 205 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-4931209GARA1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 98 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-56732-B Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-56732-U Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 230/240 VAC, 50/60 Hz NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-66642-H Manually Hand knob Drain line internal Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-4931211G0QA1152 Manually Hand knob Drain line internal Solenoid activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
056-40126-0 Manually Hand knob Drain line internal Solenoid activated unpress. circulation 98 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-53549-0 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-49312A5 Manually Hand knob Drain line internal N/A N/A FPM N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-49312P2G0RA1152 Proportional Hand knob Drain line internal N/A 12 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-49312P2G0RA5 Proportional Hand knob Drain line internal N/A 12 VDC FPM N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-49316P2G0RA1 Proportional Hand knob Drain line external from Y1-port N/A 12 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-65452-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-65013-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-4933209G0QA1152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-66950-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-65452-G Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 12 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-57833-B Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-4933211G0QA1 Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
056-40389-B Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-53655-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-65012-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
056-40324-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-5953209G0QA5152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-5953209G0RA1 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 12 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-52089-A Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 205 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-66911-T Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR Vent function with slow unloading SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-30789-H Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-57194-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-96672-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-59532A5 Manually Acorn nut with lead seal Drain line internal N/A N/A FPM N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
056-40567-G Proportional Acorn nut with lead seal Drain line internal N/A 12 VDC NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-5953609G0QA1 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-99952-0 Manually Hand knob Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V12-6951611G0QA1 Manually Hand knob Drain line external from Y1-port Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
026-71213-0 Manually Hand knob Drain line external from Y1-port N/A N/A NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V12-69516P2G0RA1 Proportional Hand knob Drain line external from Y1-port N/A 12 VDC NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V12-69516P2G0RA5 Proportional Hand knob Drain line external from Y1-port N/A 12 VDC FPM N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
026-39857-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
026-37642-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
026-39857-A Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 205 VDC NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V12-6953209GARA1 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 98 VDC NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V12-6953209W30A1152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR 3-port body with metric threads SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-6933209G0QA1008 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-6933209G0QA5152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM 3-port body with metric threads SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-6933211G0QA1152 Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-69332A1152 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
026-37000-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-69332A5152 Manually Acorn nut with lead seal Drain line internal N/A N/A FPM 3-port body with metric threads SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-69342A5152 Manually Cylinder lock Drain line internal N/A N/A FPM 3-port body with metric threads SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-6951209G0QA1152 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
026-99852-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-6951209G0QA1008 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-6951209W30A1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
056-40216-0 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
056-40367-0 Manually Hand knob Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-69512P2G0RA1 Proportional Hand knob Drain line internal N/A 12 VDC NBR N/A SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-69512P2G0RA1152 Proportional Hand knob Drain line internal N/A 12 VDC NBR 3-port body with metric threads SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-6951609G0QA1152 Manually Hand knob Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-6951611G0QA1 Manually Hand knob Drain line external from Y1-port Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-6951611G0QA1152 Manually Hand knob Drain line external from Y1-port Solenoid activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
056-40124-0 Manually Hand knob Drain line external from Y1-port N/A N/A NBR N/A SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-6953209G0QA1 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-6953209G0QA1008 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
056-40484-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-6953211G0QA1 Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-6953211G0QA1152 Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
056-40211-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V12-6953211G0QA1 Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
026-38178-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
026-96702-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V12-69532P2G0RA1152 Proportional Acorn nut with lead seal Drain line internal N/A 12 VDC NBR 3-port body with metric threads SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
026-95584-0 Manually Acorn nut with lead seal Drain line external from Y1-port N/A N/A NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V12-69542A5152 Manually Cylinder lock Drain line internal N/A N/A FPM 3-port body with metric threads SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
026-99948-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-69532A5152 Manually Acorn nut with lead seal Drain line internal N/A N/A FPM 3-port body with metric threads SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-69536A1 Manually Acorn nut with lead seal Drain line external from Y1-port N/A N/A NBR N/A SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-69536A1152 Manually Acorn nut with lead seal Drain line external from Y1-port N/A N/A NBR 3-port body with metric threads SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-6954209G0QA1152 Manually Cylinder lock Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-47112A5 Manually Hand knob Drain line internal N/A N/A FPM N/A SAE 1 1/4 SAE61 2-port, Y1 = G 1/4 105 BAR
026-70380-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 1 1/4 SAE61 2-port, Y1 = G 1/4 105 BAR
026-20900-0 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 1 1/4 SAE61 2-port, Y1 = G 1/4 210 BAR
R5V10-47332A1 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 1 1/4 SAE61 2-port, Y1 = G 1/4 210 BAR
026-96839-0 Manually Acorn nut with lead seal Drain line external from Y1-port N/A N/A NBR N/A SAE 1 1/4 SAE61 2-port, Y1 = G 1/4 210 BAR
R5V10-4751209G0QA1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/4 SAE61 2-port, Y1 = G 1/4 350 BAR
026-20901-0 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 1 1/4 SAE61 2-port, Y1 = G 1/4 350 BAR
026-99664-G Proportional Hand knob Drain line external from Y1-port N/A 12 VDC NBR N/A SAE 1 1/4 SAE61 2-port, Y1 = G 1/4 350 BAR
R5V10-47532A1 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 1 1/4 SAE61 2-port, Y1 = G 1/4 350 BAR
R5V10-4754209G0QA1 Manually Cylinder lock Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/4 SAE61 2-port, Y1 = G 1/4 350 BAR
026-65847-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-75860-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V10-4911209G0QA1152 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V10-4911209G0QA5 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V10-4911209G0QA5152 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-30514-H Manually Hand knob Drain line internal Solenoid activated unpress. circulation 24 VDC FPM N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-57422-0 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V10-49112A5 Manually Hand knob Drain line internal N/A N/A FPM N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V10-4911609G0QA1008 Manually Hand knob Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V10-49116P2G0RA1152 Proportional Hand knob Drain line external from Y1-port N/A 12 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-66977-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V10-4913209G0QA1152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
056-40453-B Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-67453-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
056-40651-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V10-49132A5 Manually Acorn nut with lead seal Drain line internal N/A N/A FPM N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V10-49132P2G0RA1 Proportional Acorn nut with lead seal Drain line internal N/A 12 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
056-40679-G Proportional Acorn nut with lead seal Drain line internal N/A 12 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V10-4913609G0QA1 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V10-4913609G0QA1152 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V10-4913609G0RA1152 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 12 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-55533-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-3911609G0QA1008 Manually Hand knob Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-67423-0 Manually Hand knob Drain line external from Y1-port N/A N/A NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-66349-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V12-3913209G0QA1008 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V12-3913209G0QA1152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V12-3913211G0QA1 Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-55749-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V12-39132A1152 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V12-39132P2G0RA1 Proportional Acorn nut with lead seal Drain line internal N/A 12 VDC NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V12-3913609G0QA1 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V12-3913609G0QA1152 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-56952-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-3931209G0QA1008 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-3931209G0QA1152 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-3931209G0RA1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 12 VDC NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-3931209GARA1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 98 VDC NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-70780-B Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-3931211G0QA1 Manually Hand knob Drain line internal Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-3931211G0RA1 Manually Hand knob Drain line internal Solenoid activated unpress. circulation 12 VDC NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-53550-0 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-39312A5 Manually Hand knob Drain line internal N/A N/A FPM N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-70848-G Proportional Hand knob Drain line internal N/A 12 VDC NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-56562-0 Manually Hand knob Drain line external from Y1-port N/A N/A NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-39316P2G0RA1 Proportional Hand knob Drain line external from Y1-port N/A 12 VDC NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-66730-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-37766-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-3933209G0QA1152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
056-40143-A Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 205 VDC NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-3933209GARA1 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 98 VDC NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-66466-T Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR Vent function with slow unloading SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-67398-U Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 230/240 VAC, 50/60 Hz NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-66466-U Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 230/240 VAC, 50/60 Hz NBR Vent function with slow unloading SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-38281-H Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-3933211GAGA1152 Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 205 VDC NBR 3-port body with metric threads SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-3933211GARA1152 Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 98 VDC NBR 3-port body with metric threads SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-3933211W30A1 Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-3933211W31A1152 Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 230/240 VAC, 50/60 Hz NBR 3-port body with metric threads SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-62425-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-75756-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-39332A5 Manually Acorn nut with lead seal Drain line internal N/A N/A FPM N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-3933609G0QA1 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-3933609G0QA1008 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-39336A1152 Manually Acorn nut with lead seal Drain line external from Y1-port N/A N/A NBR 3-port body with metric threads SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-70103-G Proportional Acorn nut with lead seal Drain line external from Y1-port N/A 12 VDC NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-39336P2G0RA1152 Proportional Acorn nut with lead seal Drain line external from Y1-port N/A 12 VDC NBR 3-port body with metric threads SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-3934209G0QA1008 Manually Cylinder lock Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-69112A1 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 105 BAR
R5V12-69112P2G0RA1 Proportional Hand knob Drain line internal N/A 12 VDC NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 105 BAR
056-40111-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 105 BAR
R5V12-69132A1152 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 105 BAR
026-99031-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-6931209W30A1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-6931209W31A1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 230/240 VAC, 50/60 Hz NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-6931211G0QA1152 Manually Hand knob Drain line internal Solenoid activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
026-38435-0 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-69312P2G0RA1 Proportional Hand knob Drain line internal N/A 12 VDC NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
026-99346-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
056-40510-S Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 230/240 VAC, 50/60 Hz NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-69332A1152 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
026-67120-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V12-6951209G0QA1008 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V12-6951209G0QA1152 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V12-6951209GARA1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 98 VDC NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V12-6951209W30A1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
056-40424-S Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 230/240 VAC, 50/60 Hz NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
026-99620-H Manually Hand knob Drain line internal Solenoid activated unpress. circulation 24 VDC FPM N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
026-71262-0 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-6931211G0QA1070 Manually Hand knob Drain line internal Solenoid activated unpress. circulation 24 VDC NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-6931211G0QA1152 Manually Hand knob Drain line internal Solenoid activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-6931211G0QA5070 Manually Hand knob Drain line internal Solenoid activated unpress. circulation 24 VDC FPM Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
026-95294-0 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
026-75755-0 Manually Hand knob Drain line internal N/A N/A NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-69312A1152 Manually Hand knob Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-69312P2G0RA1070 Proportional Hand knob Drain line internal N/A 12 VDC NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-69316P2G0RA1070 Proportional Hand knob Drain line external from Y1-port N/A 12 VDC NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-6933209G0QA1008 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
026-99757-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-6933209G0QA1152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
026-37024-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-6933209G0QA5152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-6933209W30A5 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz FPM N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-6933209W30A5152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz FPM 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-6933211G0QA1152 Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
056-40247-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-69332A1152 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-69332A5070 Manually Acorn nut with lead seal Drain line internal N/A N/A FPM Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-69332P2G0RA1070 Proportional Acorn nut with lead seal Drain line internal N/A 12 VDC NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-69336A1 Manually Acorn nut with lead seal Drain line external from Y1-port N/A N/A NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-69336P2G0RA1 Proportional Acorn nut with lead seal Drain line external from Y1-port N/A 12 VDC NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-69336P2G0RA1152 Proportional Acorn nut with lead seal Drain line external from Y1-port N/A 12 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-69342A5152 Manually Cylinder lock Drain line internal N/A N/A FPM 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
056-40099-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
026-75889-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-6951209G0QA1070 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
056-40239-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-6951209G0QA5070 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-6951209W30A1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
056-40213-S Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 230/240 VAC, 50/60 Hz NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-6951211G0QA1 Manually Hand knob Drain line internal Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-6951211G0QA1152 Manually Hand knob Drain line internal Solenoid activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
026-95872-0 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
026-96282-0 Manually Hand knob Drain line internal N/A N/A NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
056-40011-0 Manually Hand knob Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-69512A5 Manually Hand knob Drain line internal N/A N/A FPM N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-6951611G0QA1 Manually Hand knob Drain line external from Y1-port Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-6951611G0QA1070 Manually Hand knob Drain line external from Y1-port Solenoid activated unpress. circulation 24 VDC NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
056-40278-0 Manually Hand knob Drain line external from Y1-port N/A N/A NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-69516A1070 Manually Hand knob Drain line external from Y1-port N/A N/A NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-69516A1152 Manually Hand knob Drain line external from Y1-port N/A N/A NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-69516P2G0RA1 Proportional Hand knob Drain line external from Y1-port N/A 12 VDC NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-69516P2G0RA1070 Proportional Hand knob Drain line external from Y1-port N/A 12 VDC NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-69516P2G0RA1152 Proportional Hand knob Drain line external from Y1-port N/A 12 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
026-99014-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-6953209G0QA1008 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
056-40271-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-6953209G0QA5008 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM Vent function with slow unloading SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-6953209G0QA5152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
026-99568-B Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-6953211G0QA1070 Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 24 VDC NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
026-99882-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-69532A5070 Manually Acorn nut with lead seal Drain line internal N/A N/A FPM Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-6953609G0QA1008 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-6953611G0QA1 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-6953611G0QA1152 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-69536A1 Manually Acorn nut with lead seal Drain line external from Y1-port N/A N/A NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-69536A1070 Manually Acorn nut with lead seal Drain line external from Y1-port N/A N/A NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-69536P2G0RA1152 Proportional Acorn nut with lead seal Drain line external from Y1-port N/A 12 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-6954209G0QA1152 Manually Cylinder lock Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-69542A1 Manually Cylinder lock Drain line internal N/A N/A NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
026-56585-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V12-3911209G0QA1008 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V12-3911209G0QA1152 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-62442-0 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-71064-0 Manually Hand knob Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V12-39112A5 Manually Hand knob Drain line internal N/A N/A FPM N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V12-39112P2G0RA1152 Proportional Hand knob Drain line internal N/A 12 VDC NBR 3-port body with metric threads SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V06-5711209G0QA1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 3/4 SAE61 2-port, Y1 = G 1/4 105 BAR
026-99662-G Manually Hand knob Drain line external from Y1-port Solenoid not activated unpress. circulation 12 VDC NBR N/A SAE 3/4 SAE61 2-port, Y1 = G 1/4 105 BAR
026-20984-5 Manually Hand knob Drain line external from Y1-port N/A N/A FPM N/A SAE 3/4 SAE61 2-port, Y1 = G 1/4 105 BAR
R5V06-57132A1 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 3/4 SAE61 2-port, Y1 = G 1/4 105 BAR
R5V06-5713609G0QA1 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 3/4 SAE61 2-port, Y1 = G 1/4 105 BAR
026-99904-0 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 3/4 SAE61 2-port, Y1 = G 1/4 210 BAR
R5V06-5751209G0QA1008 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 3/4 SAE61 2-port, Y1 = G 1/4 350 BAR
026-66021-0 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 3/4 SAE61 2-port, Y1 = G 1/4 350 BAR
R5V06-57516P2G0RA1 Proportional Hand knob Drain line external from Y1-port N/A 12 VDC NBR N/A SAE 3/4 SAE61 2-port, Y1 = G 1/4 350 BAR
R5V06-57532A1 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 3/4 SAE61 2-port, Y1 = G 1/4 350 BAR
R5V06-5753609G0QA1 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 3/4 SAE61 2-port, Y1 = G 1/4 350 BAR
026-66447-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V06-5911209G0QA1152 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-38935-B Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
056-40201-H Manually Hand knob Drain line internal Solenoid activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-56592-0 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
056-40259-G Proportional Hand knob Drain line external from Y1-port N/A 12 VDC NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V06-5913209G0QA1 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V06-5913209G0QA1152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-67162-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V06-59132A1152 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR 3-port body with metric threads SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-66639-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-95442-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-37659-5 Manually Acorn nut with lead seal Drain line internal N/A N/A FPM N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
056-40680-G Proportional Acorn nut with lead seal Drain line internal N/A 12 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-4933609G0QA1152 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-56987-0 Manually Acorn nut with lead seal Drain line external from Y1-port N/A N/A NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-49336P2G0RA1152 Proportional Acorn nut with lead seal Drain line external from Y1-port N/A 12 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-4934209G0QA1008 Manually Cylinder lock Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-4934209G0QA1152 Manually Cylinder lock Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-49342A5152 Manually Cylinder lock Drain line internal N/A N/A FPM 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-65506-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-65887-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-4951209G0QA5152 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-65506-G Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 12 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-4951209GAGA1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 205 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-4951209GARA1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 98 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-54483-B Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-57295-0 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-49512A1152 Manually Hand knob Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-49512P2G0RA1 Proportional Hand knob Drain line internal N/A 12 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-49512P2G0RA5 Proportional Hand knob Drain line internal N/A 12 VDC FPM N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-4951609G0QA1 Manually Hand knob Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-56288-0 Manually Hand knob Drain line external from Y1-port N/A N/A NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-49516A1152 Manually Hand knob Drain line external from Y1-port N/A N/A NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-57152-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-71586-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-4953209G0QA1152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-37572-0 Manually Acorn nut with lead seal Drain line external from Y1-port N/A N/A NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-56233-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-56233-G Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 12 VDC NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V06-5931209W30A1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-66828-U Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 230/240 VAC, 50/60 Hz NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-53547-0 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
056-40343-0 Manually Hand knob Drain line internal N/A N/A NBR 3-port body with metric threads SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-66478-G Proportional Hand knob Drain line external from Y1-port N/A 12 VDC NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-62511-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-65008-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V06-5933209G0RA1 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 12 VDC NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V06-5933209GARA1 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 98 VDC NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V06-5933209W30A1152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR 3-port body with metric threads SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-65009-T Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR Vent function with slow unloading SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V06-5933211G0QA1 Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-57815-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
056-40107-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR 3-port body with metric threads SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-57815-5 Manually Acorn nut with lead seal Drain line internal N/A N/A FPM N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
056-40681-G Proportional Acorn nut with lead seal Drain line internal N/A 12 VDC NBR 3-port body with metric threads SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V06-5933609W31A1 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 230/240 VAC, 50/60 Hz NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-57548-0 Manually Acorn nut with lead seal Drain line external from Y1-port N/A N/A NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V06-59336P2G0RA1 Proportional Acorn nut with lead seal Drain line external from Y1-port N/A 12 VDC NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V06-5951209G0QA1152 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-56584-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-30556-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-5951209G0QA5 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-37001-U Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 230/240 VAC, 50/60 Hz NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-4953211G0QA1 Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-65000-5 Manually Acorn nut with lead seal Drain line internal N/A N/A FPM N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-49532A5152 Manually Acorn nut with lead seal Drain line internal N/A N/A FPM 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-99363-G Proportional Acorn nut with lead seal Drain line internal N/A 12 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-95864-0 Manually Acorn nut with lead seal Drain line external from Y1-port N/A N/A NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-49536P2G0RA1152 Proportional Acorn nut with lead seal Drain line external from Y1-port N/A 12 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-49536P2G0RA5 Proportional Acorn nut with lead seal Drain line external from Y1-port N/A 12 VDC FPM N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-4954209G0QA1008 Manually Cylinder lock Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-49542A1152 Manually Cylinder lock Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-6911209G0QA1152 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 105 BAR
R5V10-69112A1 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 105 BAR
R5V10-69112A1070 Manually Hand knob Drain line internal N/A N/A NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 105 BAR
R5V10-69112A1152 Manually Hand knob Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 105 BAR
026-99883-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 105 BAR
R5V10-69136P2G0RA1152 Proportional Acorn nut with lead seal Drain line external from Y1-port N/A 12 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 105 BAR
056-40222-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-6931209G0QA1070 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-6931209G0QA1152 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-6931209W30A1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
026-99399-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR 3-port body with metric threads SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-59532A5 Manually Acorn nut with lead seal Drain line internal N/A N/A FPM N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-59532P2G0RA1 Proportional Acorn nut with lead seal Drain line internal N/A 12 VDC NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-5953609G0QA1 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-5951209G0QA5152 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM 3-port body with metric threads SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-5951209G0RA1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 12 VDC NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-5951209W31A1008 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 230/240 VAC, 50/60 Hz NBR Vent function with slow unloading SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-57174-U Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 230/240 VAC, 50/60 Hz NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-5951209W31A1152 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 230/240 VAC, 50/60 Hz NBR 3-port body with metric threads SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-59512A1152 Manually Hand knob Drain line internal N/A N/A NBR 3-port body with metric threads SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-56234-0 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-56234-5 Manually Hand knob Drain line internal N/A N/A FPM N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-75902-G Proportional Hand knob Drain line internal N/A 12 VDC NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-59512P2G0RA1152 Proportional Hand knob Drain line internal N/A 12 VDC NBR 3-port body with metric threads SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-56289-H Manually Hand knob Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-59516A1152 Manually Hand knob Drain line external from Y1-port N/A N/A NBR 3-port body with metric threads SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-66072-0 Manually Hand knob Drain line external from Y1-port N/A N/A NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-66036-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-65010-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
056-40346-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-67514-B Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-65443-T Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR Vent function with slow unloading SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-67514-U Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 230/240 VAC, 50/60 Hz NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-52252-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-56231-H Manually Hand knob Drain line internal Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-5931211G0QA1152 Manually Hand knob Drain line internal Solenoid activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-59312A1152 Manually Hand knob Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-53548-0 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-59312P2G0RA1 Proportional Hand knob Drain line internal N/A 12 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V06-59536A1152 Manually Acorn nut with lead seal Drain line external from Y1-port N/A N/A NBR 3-port body with metric threads SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-59536P2G0RA1 Proportional Acorn nut with lead seal Drain line external from Y1-port N/A 12 VDC NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
056-40194-G Proportional Acorn nut with lead seal Drain line external from Y1-port N/A 12 VDC NBR 3-port body with metric threads SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-5954209G0QA1008 Manually Cylinder lock Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-6911209G0QA1152 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 105 BAR
R5V06-69116P2G0RA1 Proportional Hand knob Drain line external from Y1-port N/A 12 VDC NBR N/A SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 105 BAR
R5V06-6931209G0QA1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V06-6931209W30A1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V06-69312P2G0RA1 Proportional Hand knob Drain line internal N/A 12 VDC NBR N/A SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V06-6933209G0QA1 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-6933209G0QA1152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V06-69332A1152 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR 3-port body with metric threads SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V06-6951209G0QA1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-6951209G0QA1152 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-6951209G0QA1008 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-69512A1 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-69512A1152 Manually Hand knob Drain line internal N/A N/A NBR 3-port body with metric threads SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-69512P2G0RA1 Proportional Hand knob Drain line internal N/A 12 VDC NBR N/A SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-6951611G0QA1 Manually Hand knob Drain line external from Y1-port Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-6953209G0QA1008 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-6953209G0QA1152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-6953211G0QA1 Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
056-40385-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
056-40394-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR 3-port body with metric threads SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
026-53866-H Manually Hand knob Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-5931609G0QA1008 Manually Hand knob Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-5931611G0QA1 Manually Hand knob Drain line external from Y1-port Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-5931611W31A1 Manually Hand knob Drain line external from Y1-port Solenoid activated unpress. circulation 230/240 VAC, 50/60 Hz NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-59316A1 Manually Hand knob Drain line external from Y1-port N/A N/A NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-59316P2G0RA1 Proportional Hand knob Drain line external from Y1-port N/A 12 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-57500-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
056-40674-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-5933209G0QA5008 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM Vent function with slow unloading SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-5933209G0QA5152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-99805-0 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 98 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-66073-B Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-65011-T Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR Vent function with slow unloading SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-65011-U Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 230/240 VAC, 50/60 Hz NBR Vent function with slow unloading SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-5933211G0QA1 Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-53645-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-37292-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-53645-5 Manually Acorn nut with lead seal Drain line internal N/A N/A FPM N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-75559-5 Manually Acorn nut with lead seal Drain line internal N/A N/A FPM 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-59332P2G0RA1 Proportional Acorn nut with lead seal Drain line internal N/A 12 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-5933609G0QA1 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-5933609G0QA1008 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-5933609G0QA1152 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-5933609G0RA1152 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 12 VDC NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V06-69536A1 Manually Acorn nut with lead seal Drain line external from Y1-port N/A N/A NBR N/A SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-69536A1152 Manually Acorn nut with lead seal Drain line external from Y1-port N/A N/A NBR 3-port body with metric threads SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-6954611G0QA1 Manually Cylinder lock Drain line external from Y1-port Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-5711209G0QA1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 2-port, Y1 = G 1/4 105 BAR
026-37060-0 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 1 SAE61 2-port, Y1 = G 1/4 105 BAR
026-96981-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 1 SAE61 2-port, Y1 = G 1/4 105 BAR
056-40070-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 2-port, Y1 = G 1/4 210 BAR
R5V08-5731209W30A5 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz FPM N/A SAE 1 SAE61 2-port, Y1 = G 1/4 210 BAR
026-99663-H Manually Hand knob Drain line external from Y1-port Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 2-port, Y1 = G 1/4 210 BAR
R5V08-5733209G0QA1 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 2-port, Y1 = G 1/4 210 BAR
R5V08-5733209W31A1008 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 230/240 VAC, 50/60 Hz NBR Vent function with slow unloading SAE 1 SAE61 2-port, Y1 = G 1/4 210 BAR
R5V08-5733611G0QA1 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 2-port, Y1 = G 1/4 210 BAR
056-40251-0 Manually Acorn nut with lead seal Drain line external from Y1-port N/A N/A NBR N/A SAE 1 SAE61 2-port, Y1 = G 1/4 210 BAR
026-57891-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 2-port, Y1 = G 1/4 350 BAR
026-20902-0 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 1 SAE61 2-port, Y1 = G 1/4 350 BAR
R5V08-57512P2G0RA1 Proportional Hand knob Drain line internal N/A 12 VDC NBR N/A SAE 1 SAE61 2-port, Y1 = G 1/4 350 BAR
R5V08-57516P2G0RA1 Proportional Hand knob Drain line external from Y1-port N/A 12 VDC NBR N/A SAE 1 SAE61 2-port, Y1 = G 1/4 350 BAR
R5V08-57516P2G0RA5 Proportional Hand knob Drain line external from Y1-port N/A 12 VDC FPM N/A SAE 1 SAE61 2-port, Y1 = G 1/4 350 BAR
026-39404-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 2-port, Y1 = G 1/4 350 BAR
026-39404-B Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 SAE61 2-port, Y1 = G 1/4 350 BAR
R5V08-57532A1 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 1 SAE61 2-port, Y1 = G 1/4 350 BAR
026-62297-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V08-5911209W30A1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V08-5911209W31A1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 230/240 VAC, 50/60 Hz NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-56227-0 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-67763-G Proportional Hand knob Drain line internal N/A 12 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-96181-H Manually Hand knob Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-95683-H Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-59336P2G0RA1 Proportional Acorn nut with lead seal Drain line external from Y1-port N/A 12 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-59336P2G0RA1152 Proportional Acorn nut with lead seal Drain line external from Y1-port N/A 12 VDC NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-5934209G0QA1008 Manually Cylinder lock Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-5951209G0QA1152 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-56232-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-65888-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-56232-G Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 12 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
056-40103-0 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 98 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-62510-B Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-62510-U Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 230/240 VAC, 50/60 Hz NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-5951211G0QA1152 Manually Hand knob Drain line internal Solenoid activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-59512A1152 Manually Hand knob Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-56228-0 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-65939-0 Manually Hand knob Drain line internal N/A N/A FPM N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-59512P2G0RA1 Proportional Hand knob Drain line internal N/A 12 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-59512P2G0RA1152 Proportional Hand knob Drain line internal N/A 12 VDC NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-5951609G0QA1008 Manually Hand knob Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-56290-H Manually Hand knob Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-5951609W30A1 Manually Hand knob Drain line external from Y1-port Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-71417-H Manually Hand knob Drain line external from Y1-port Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-56560-0 Manually Hand knob Drain line external from Y1-port N/A N/A NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-59516A5 Manually Hand knob Drain line external from Y1-port N/A N/A FPM N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-65841-G Proportional Hand knob Drain line external from Y1-port N/A 12 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-5913209G0QA1 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V08-5913209G0QA1152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-62911-B Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V08-5913211G0QA1 Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V08-5913211G0QA1152 Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-56962-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-95359-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V08-59136A1 Manually Acorn nut with lead seal Drain line external from Y1-port N/A N/A NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-99465-G Proportional Acorn nut with lead seal Drain line external from Y1-port N/A 12 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V08-5931209G0QA1152 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-56094-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-66502-H Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-5931209G0QA5 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-56094-G Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 12 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-5931209GARA1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 98 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-56229-B Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-56229-S Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 230/240 VAC, 50/60 Hz NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
056-40160-H Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-5953609G0RA1152 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 12 VDC NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-59536A1 Manually Acorn nut with lead seal Drain line external from Y1-port N/A N/A NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-66347-G Proportional Acorn nut with lead seal Drain line external from Y1-port N/A 12 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-99835-G Proportional Acorn nut with lead seal Drain line external from Y1-port N/A 12 VDC NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-59536P2G0RA5 Proportional Acorn nut with lead seal Drain line external from Y1-port N/A 12 VDC FPM N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-6913209G0QA1 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 105 BAR
R5V08-69312A5 Manually Hand knob Drain line internal N/A N/A FPM N/A SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-6931609G0QA1 Manually Hand knob Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V06-5931211G0QA5152 Manually Hand knob Drain line internal Solenoid activated unpress. circulation 24 VDC FPM 3-port body with metric threads SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V06-6953209G0QA5152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM 3-port body with metric threads SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-5933209G0QA1 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-5933209W30A1152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-5953209G0QA5 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-5953209W31A1152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 230/240 VAC, 50/60 Hz NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-59532A525152 Manually Acorn nut with lead seal Drain line internal N/A N/A FPM 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-6931211W31A1 Manually Hand knob Drain line internal Solenoid activated unpress. circulation 230/240 VAC, 50/60 Hz NBR N/A SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-69312A1 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-4711209G0QA1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/4 SAE61 2-port, Y1 = G 1/4 105 BAR
R5V10-47332A5 Manually Acorn nut with lead seal Drain line internal N/A N/A FPM N/A SAE 1 1/4 SAE61 2-port, Y1 = G 1/4 210 BAR
R5V10-49136A1 Manually Acorn nut with lead seal Drain line external from Y1-port N/A N/A NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V10-49316A1 Manually Hand knob Drain line external from Y1-port N/A N/A NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-49332A5152 Manually Acorn nut with lead seal Drain line internal N/A N/A FPM 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-65000-0 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-6931209G0QA1008 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-6951209G0QA5 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-6953209G0QA5070 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
056-40009-H Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-69536P2G0RA1070 Proportional Acorn nut with lead seal Drain line external from Y1-port N/A 12 VDC NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-6954209G0QA1 Manually Cylinder lock Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-69542A1070 Manually Cylinder lock Drain line internal N/A N/A NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-69546A1152 Manually Cylinder lock Drain line external from Y1-port N/A N/A NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V12-3933209W30A1 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-3933211G0RA1 Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 12 VDC NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-39336A1 Manually Acorn nut with lead seal Drain line external from Y1-port N/A N/A NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-6953609G0QA1 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-5951209W30A1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-6953211G0QA1008 Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-57116A1 Manually Hand knob Drain line external from Y1-port N/A N/A NBR N/A SAE 1 SAE61 2-port, Y1 = G 1/4 105 BAR
R5V08-59316A5 Manually Hand knob Drain line external from Y1-port N/A N/A FPM N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-5953209GARA1152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 98 VDC NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-5953209W30A1152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR 3-port body with metric threads SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-49532A1152 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-6931211W30A1 Manually Hand knob Drain line internal Solenoid activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-6953209G0QA1070 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-6953211G0QA1008 Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-69532A1152 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V12-6951209G0QA5 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V12-6953211G0QA1008 Manually Acorn nut with lead seal Drain line internal Solenoid activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-59312A5 Manually Hand knob Drain line internal N/A N/A FPM N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-59312A5 Manually Hand knob Drain line internal N/A N/A FPM N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-4933209GARA1 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 98 VDC NBR Vent function with slow unloading SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-69136A1 Manually Acorn nut with lead seal Drain line external from Y1-port N/A N/A NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 105 BAR
R5V12-69312A5 Manually Hand knob Drain line internal N/A N/A FPM N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-69332A1 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V06-5911211G0QA1 Manually Hand knob Drain line internal Solenoid activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V06-5953209G0QA5 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM Vent function with slow unloading SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-69532A5 Manually Acorn nut with lead seal Drain line internal N/A N/A FPM N/A SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-59116A5 Manually Hand knob Drain line external from Y1-port N/A N/A FPM N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V10-4931211W30A1 Manually Hand knob Drain line internal Solenoid activated unpress. circulation 110/120 VAC, 50/60 Hz NBR Vent function with slow unloading SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-3931209W31A1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 230/240 VAC, 50/60 Hz NBR Vent function with slow unloading SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-6951211W31A1 Manually Hand knob Drain line internal Solenoid activated unpress. circulation 230/240 VAC, 50/60 Hz NBR Vent function with slow unloading SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V12-69512A5 Manually Hand knob Drain line internal N/A N/A FPM N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V12-69516A5 Manually Hand knob Drain line external from Y1-port N/A N/A FPM N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-6951209W30A1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-59132P2G0RA1 Proportional Acorn nut with lead seal Drain line internal N/A 12 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V08-6931209G0QA1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-69532P2G0RA1152 Proportional Acorn nut with lead seal Drain line internal N/A 12 VDC NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V12-39332P2G0RA1 Proportional Acorn nut with lead seal Drain line internal N/A 12 VDC NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-69532A5152 Manually Acorn nut with lead seal Drain line internal N/A N/A FPM 3-port body with metric threads SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V12-39132P2G0RA5 Proportional Acorn nut with lead seal Drain line internal N/A 12 VDC FPM N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V08-69532P2G0RA1152 Proportional Acorn nut with lead seal Drain line internal N/A 12 VDC NBR 3-port body with metric threads SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-5953609G0RA1 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 12 VDC NBR N/A SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-37337-U Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 230/240 VAC, 50/60 Hz NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-3913209GAGA1 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 205 VDC NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V10-6933609G0QA1070 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-6931209G0RA1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 12 VDC NBR N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-4953609G0RA1 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 12 VDC NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-49532A1070 Manually Acorn nut with lead seal Drain line internal N/A N/A NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-49142A1 Manually Cylinder lock Drain line internal N/A N/A NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V10-4913609G0RA1070 Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. circulation 12 VDC NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-70671-B Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
R5V10-69542A1152 Manually Cylinder lock Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-6954211G0QA5 Manually Cylinder lock Drain line internal Solenoid activated unpress. circulation 24 VDC FPM N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-4953209W30A1 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR N/A SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
056-40379-H Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-49112A1152 Manually Hand knob Drain line internal N/A N/A NBR 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 105 BAR
026-95683-G Manually Acorn nut with lead seal Drain line external from Y1-port Solenoid activated unpress. circulation 12 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
026-55631-G Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 12 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-6933209G0QA1152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
026-99620-S Manually Hand knob Drain line internal Solenoid activated unpress. circulation 230/240 VAC, 50/60 Hz NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V12-6951211G0QA1152 Manually Hand knob Drain line internal Solenoid activated unpress. circulation 24 VDC NBR 3-port body with metric threads SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V12-6931609G0QA1008 Manually Hand knob Drain line external from Y1-port Solenoid not activated unpress. circulation 24 VDC NBR Vent function with slow unloading SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V06-59336P2G0RA1152 Proportional Acorn nut with lead seal Drain line external from Y1-port N/A 12 VDC NBR 3-port body with metric threads SAE 3/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-6931209G0RA1 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 12 VDC NBR N/A SAE 1 1/2 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
026-70778-0 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
026-71934-5 Manually Acorn nut with lead seal Drain line external from Y1-port N/A N/A FPM N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-6951211G0QA1070 Manually Hand knob Drain line internal Solenoid activated unpress. circulation 24 VDC NBR Metric 3-port body, port A: 15 mm, SAE62 with 15 mm, tank port: SAE61 SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V06-6951211G0QA1 Manually Hand knob Drain line internal Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 BAR
R5V08-5951211G0QA1 Manually Hand knob Drain line internal Solenoid activated unpress. circulation 24 VDC NBR N/A SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 BAR
R5V10-4933209G0QA5152 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 24 VDC FPM 3-port body with metric threads SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V06-69312A5152 Manually Hand knob Drain line internal N/A N/A FPM N/A SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V08-5931609W30A1 Manually Hand knob Drain line external from Y1-port Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz NBR Vent function with slow unloading SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-4931209W30A5 Manually Hand knob Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz FPM Vent function with slow unloading SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-4933209W30A5 Manually Acorn nut with lead seal Drain line internal Solenoid not activated unpress. circulation 110/120 VAC, 50/60 Hz FPM Vent function with slow unloading SAE 1 1/4 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR
R5V10-69312A5 Manually Hand knob Drain line internal N/A N/A FPM N/A SAE 1 1/4 SAE62 3-port, Y1, X1, M = G 1/4 210 BAR
R5V12-39312A1152 Manually Hand knob Drain line internal N/A N/A NBR N/A SAE 1 1/2 SAE61 3-port, Y1, X1, M = G 1/4 210 BAR

687466
687478