P Series Heavy Duty Spool valve for critical Process control applications | Product Series

Filter by

    No filters selected

Function

Maximum Fluid Temperature

Power Supply Voltage

Electrical Connection

Specifications Met

Port Size

Body Material

Orifice Size

Maximum Operating Pressure

Minimum Fluid Temperature

Get your Parker account Today!

Create one account to manage everything you do with Parker, from your shopping preferences to your application access.


LOADING IMAGES
P Series Heavy Duty Spool valve for critical Process control applications

P Series Heavy Duty Spool valve for critical Process control applications

P Series of Heavy Duty Ported Spool valves is a full range of indirect operated valves, solenoid or air operated, delivering a borad range of functions including 3/2, 5/2, 5/3.

Technical Specifications

  • Valve Type: 5/2 way
  • Actuation Type: PILOT OPERATED
  • Port Type: PIPE MOUNTING
  • Media: Air
  • Flow Coefficient: 600 l/min, 1400 l/min, 400 l/min, 1250 l/min, 3000 l/min
  • Minimum Operating Pressure: 2 bar AC/DC, 2 bar, 2 bar , 2 bar DC, 2,5 bar AC/DC
  • Seal Material: NBR
  • Coil Power Consumption: -, 2.5W, 2W, 3W, 8W, 9W, 0.3W to 1.2W, 6 W
  • Coil Temperature Range: -, -40°C +50°C, -40°C +80°C, -40°C +85°C / +65°C, -40°C +80°C / +75°C / +65°C, -40°C +80°C / +65°C / +55°C, -40°C +75°C / +40°C
  • Insulation Class: -, F 155 °C, H 180 °C
  • Coil Specifications Met: -, CE - EAC, CE, CE - VDE - EAC
  • ATEX Specifications Met: -, II 2 G Ex db mb IIC T4, II 2 G - Ex mb IIC T4 / T5, II 1 G - Ex ia IIC - T4 / T5 / T6, II 2 G - Ex db mb IIC T4 / T5 / T6, II 2 G - Ex eb mb II T4 / T5
Safety Warning

Full Product Description

The P Series Heavy Duty Ported Spool valve series includes many product solutions for Valve Actuation in the Process Industry. This range delivers an unmatched high flow performance, up to 1400 l/min. The spool design and materials makes this product extremely reliable either for low and high frequency applications making it the best choice for critical process control applications. This product solution modularity in combination with our ATEX coils program can optimize the total ownership costs delivering high reliability, extreme flexibility and best competitiveness. This range is SIL approved by third party.

Markets:
- Pharmaceutical
- Food&Beverage production, storage
- Water treatment
- Refineries
- Powders dosing

Applications:
- Valve Actuation

Features/Benefits:
- High Flow Performance
- SIL approval
- Atex

Related Documents

Literature and Reference Materials
Parker--General Catalogue--0112UK
Product Demos & Tutorials
Solenoid Valves Overview Video
×
Products Function Maximum Fluid Temperature Power Supply Voltage Electrical Connection Specifications Met Port Size Body Material Orifice Size Maximum Operating Pressure Minimum Fluid Temperature
341P03 NORMALLY CLOSED +50°C - - Manual Override G 1/4 Anodized aluminium 7 mm 10 bar AC/DC -10°C
345P21 CONTROLLED BY ELECTRIC IMPULSE +80°C - - With manual override. In line operator, pilot seat in FKM. G 1/8 Anodized aluminium 4 mm 10 bar -25°C
341P01-8993-488980C2 Normally Closed +50°C 2.5 W 2P+E plug according to EN 175301-803 type B - 1/8"G Anodized Aluminium 4 mm 2 bar -25°C
341P02-8993-4889803D Normally Closed +50°C 2 W 2P+E plug according to EN 175301-803 type B - 1/4" G Anodized Aluminium 8 mm 2 bar -25°C
341P02-8993-488980C2 Normally Closed +50°C 2.5 W 2P+E plug according to EN 175301-803 type B - 1/4" G Anodized Aluminium 8 mm 2 bar -25°C
341P03-496131C2 Normally Closed +50°C 3 W 2P+E plug according to EN 175301-803 type B - 1/4" G Anodized Aluminium 7 mm 2.5 bar -10°C
341P03-496131P9 Normally Closed +50°C 3 W 2P+E plug according to EN 175301-803 type B - 1/4" G Anodized Aluminium 7 mm 2.5 bar -10°C
341P03-496131S4 Normally Closed +50°C 3 W 2P+E plug according to EN 175301-803 type B - 1/4" G Anodized Aluminium 7 mm 2.5 bar -10°C
341P04 Normally Closed +50°C - - - 1/2" G Anodized Aluminium 12 mm 2.5 bar -10°C
341P21-2995-481865C2 Normally Closed +80°C 8 W 2P+E plug according to EN 175301-803 type A - 1/8" G Anodized Aluminium 4 mm 2 bar -25°C
341P2108-2995-481865C2 Normally Closed +65°C 8 W 2P+E plug according to EN 175301-803 type A - 1/8" G Anodized Aluminium 4 mm 2 bar -40°C
341P22-2995-481865C2 Normally Closed +80°C 8 W 2P+E plug according to EN 175301-803 type A - 1/4" G Anodized Aluminium 8 mm 2 bar -25°C
341P2290-2995-48358001N7 Normally Closed +55°C 0.5 W 2P+E plug according to EN 175301-803 type A - 1/4" G Anodized Aluminium 8 mm 2 bar -25°C
341P33 Normally Closed +50°C - - - 1/4" G Anodized Aluminium 7 mm 2.5 bar -20°C
341P3397 Normally Closed +50°C - - - 1/4" G Anodized Aluminium 7 mm 2.5 bar -20°C
341P34 Normally Closed +50°C - - - 1/2" G Anodized Aluminium 12 mm 2.5 bar -10°C
341P3496 Normally Closed +50°C - - - 1/2" G Anodized Aluminium 12 mm 2.5 bar -20°C
347P21 Dual Solenoid +80°C - - - 1/8" G Anodized Aluminium 4 mm 2 bar -25°C
347P2197 Dual Solenoid +65°C - - - 1/8" G Anodized Aluminium 4 mm 2 bar -20°C
347P22-495905C2 Dual Solenoid +80°C 8 W M20x1.5 II 2 G Ex db mb IIC T4 1/4" G Anodized Aluminium 8 mm 2 bar -25°C
347P33 Dual Solenoid +50°C - - - 1/4" G Anodized Aluminium 7 mm 2.5 bar -10°C
347P34 Dual Solenoid +50°C - - - 1/2" G Anodized Aluminium 12 mm 2.5 bar -10°C
341P01 NORMALLY CLOSED +80°C - - Manual Override G 1/8 Anodized aluminium 4 mm 10 bar AC/DC -25°C
341P01-8993-481045A2 NORMALLY CLOSED +75°C 24V 50Hz 2 P + E plug according to EN 175301-803 type B (connector included) With manual override. In line operator, pilot seat in FKM. G 1/8 Anodized aluminium 4 mm 10 bar -25°C
341P01-8993-481045C2 NORMALLY CLOSED +75°C 24V DC 2 P + E plug according to EN 175301-803 type B (connector included) With manual override. In line operator, pilot seat in FKM. G 1/8 Anodized aluminium 4 mm 10 bar -25°C
341P01-8993-488980A2 NORMALLY CLOSED +75°C 24V 50Hz 2 P + E plug according to EN 175301-803 type B With manual override. In line operator, pilot seat in FKM. G 1/8 Anodized aluminium 4 mm 10 bar -25°C
341P02 NORMALLY CLOSED +80°C - - Manual Override G 1/4 Anodized aluminium 8 mm 10 bar AC/DC -25°C
341P02-8993-488980A2 NORMALLY CLOSED +80°C 24V 50Hz 2 P + E plug according to EN 175301-803 type B With manual override. In line operator, pilot seat in FKM. G 1/4 Anodized aluminium 8 mm 10 bar -25°C
341P02-8993-488980A4 NORMALLY CLOSED +80°C 48V 50Hz 2 P + E plug according to EN 175301-803 type B With manual override. In line operator, pilot seat in FKM. G 1/4 Anodized aluminium 8 mm 10 bar -25°C
341P21 NORMALLY CLOSED +80°C - - With manual override. In line operator, pilot seat in FKM. G 1/8 Anodized aluminium 4 mm 10 bar AC/DC -25°C
341P21-495905C2 NORMALLY CLOSED +80°C 24V DC Electric connection is done in the connection box on an easily accessible connector terminals. With manual override. In line operator, pilot seat in FKM. G 1/8 Anodized aluminium 4 mm 10 bar -25°C
341P21-495905F4 NORMALLY CLOSED +80°C 230V 50Hz Electric connection is done in the connection box on an easily accessible connector terminals. With manual override. In line operator, pilot seat in FKM. G 1/8 Anodized aluminium 4 mm 10 bar -25°C
341P2108 NORMALLY CLOSED +65°C - - With manual override. In line operator, pilot seat in PUR. G 1/8 Anodized aluminium 4 mm 10 bar AC/DC -40°C
341P2190 NORMALLY CLOSED +65°C - - Intrinsically safe. In line operator, pilot seat in FKM. G 1/8 Anodized aluminium 4 mm 10 bar DC -10°C
341P2197 NORMALLY CLOSED +65°C - - With manual override. In line operator, pilot seat in PUR. G 1/8 Anodized aluminium 4 mm 10 bar AC/DC -25°C
341P22 NORMALLY CLOSED +80°C - - With manual override. In line operator, pilot seat in FKM. G 1/4 Anodized aluminium 8 mm 10 bar AC/DC -25°C
341P22-495905C2 NORMALLY CLOSED +80°C 24V DC Electric connection is done in the connection box on an easily accessible connector terminals. With manual override. In line operator, pilot seat in FKM. G 1/4 Anodized aluminium 8 mm 10 bar -25°C
341P2290 NORMALLY CLOSED +75°C - - Intrinsically safe. In line operator, pilot seat in FKM. G 1/4 Anodized aluminium 8 mm 10 bar DC -25°C
341P2297 NORMALLY CLOSED +65°C - - With manual override. In line operator, pilot seat in PUR. G 1/4 Anodized aluminium 8 mm 10 bar AC/DC -25°C
347P01 DUAL SOLENOIDS +80°C - - With manual override. In line operators, pilots seat in FKM G 1/8 Anodized aluminium 4 mm 10 bar AC/DC -25°C
347P02 DUAL SOLENOIDS +80°C - - With manual override. In line operators. 22mm Operators G 1/4 Anodized aluminium 8 mm 10 bar AC/DC -25°C
347P03 DUAL SOLENOIDS +50°C - - With manual override. In line operators. G 1/4 Anodized aluminium 7 mm 10 bar AC/DC -20°C
347P04 DUAL SOLENOIDS +50°C - - With manual override. In line operators. G 1/2 Anodized aluminium 12 mm 10 bar AC/DC -20°C
347P2190 DUAL SOLENOIDS +75°C - - Intrinsically safe. In line operators. G 1/8 Anodized aluminium 4 mm 10 bar DC -25°C
347P22 DUAL SOLENOIDS +80°C - - With manual override. In line operators. G 1/4 Anodized aluminium 8 mm 10 bar AC/DC -25°C
U341P3250 NORMALLY CLOSED +80°C - - Perpendicular operator, pilot seat in FKM. 1/4 - 3/8 NPT Stainless steel 8 mm 10 bar AC/DC -25°C
U341P3250-495905C2 NORMALLY CLOSED +80°C 24V DC Electric connection is done in the connection box on an easily accessible connector terminals. Perpendicular operator, pilot seat in FKM. 1/4 - 3/8 NPT Stainless steel 8 mm 10 bar -25°C
U341P3295 NORMALLY CLOSED +75°C - - Perpendicular operator, pilot seat in FKM. 1/4 - 3/8 NPT Stainless steel 8 mm 10 bar AC/DC -25°C
U347P3295 DUAL SOLENOIDS +75°C - - Perpendicular operators, pilots seat in FKM. 1/4 - 3/8 NPT Stainless steel 8 mm 10 bar AC/DC -25°C

687466