Hyperchill Laser Industrial Process Chiller for Precision Cooling | Product Series

Filter by

    No filters selected

Maximum Cooling Capacity

Cooling Method

Power Supply Voltage

Pump Type

Additional Protection Included

Operating Environment

Water Sensor Option

Hydraulic Circuit

Output Water Temperature Range

Get your Parker account Today!

Create one account to manage everything you do with Parker, from your shopping preferences to your application access.


LOADING IMAGES
Hyperchill Laser Industrial Process Chiller for Precision Cooling

Hyperchill Laser Industrial Process Chiller for Precision Cooling OBSOLETE

This product is no longer available, please refer to Hyperchill Plus-E 50Hz Range instead.

Technical Specifications

  • Division: Gas Separation and Filtration Division EMEA
  • Brand: Hiross
  • Technology: Thermal and Power Management
  • Application: Precision Cooling of Low Viscosity Industrial Cooling Fluids for Laser Marking, Cutting and Welding
  • Product Type: Production Process Water Chiller
  • Product Style: Pressurized Closed Hydraulic Circuit
  • Product Series: Hyperchill Laser
  • Industry: Laser and Metal
  • Maximum Cooling Capacity: 76 to 115.5 kW @ 25°C (63°C)
  • Operating Environment: Low Ambient -10°C (Fan Step Control)
  • Output Water Temperature Range: Close Control +/- 0.5°C
  • Additional Protection Included: With or Without Antifreeze
  • Pump Type: View Part Number for Details.
  • Cooling Method: Air Cooled
  • Hydraulic Circuit: Stainless Steel with Tank
  • Water Sensor Option: No Low Water
  • Power Supply Voltage: 400 VAC (3ph/50Hz)
  • Port Size: 2 inch
  • Port Type: Threaded
  • Number of Axial Fans: 3
  • Refrigerant Type: R407C
  • Tank Capacity: 300 L
  • Operating Temperature: 5 to 30 °C, 41 to 86 °F
  • Ambient Temperature: 45 °C (max.), 113 °F (max.)
  • For Fluid Type: Water
  • Specifications Met: PED 97/23/EC, Machinery Directive 2006/42/EC, Electromagnetic Directive 2004/108/EC
  • Ingress Protection Rating: IP54
  • Compressor Included: Hermetic Scroll
  • Noise Level: 58 dBA
  • Height: 1984 mm, 78.1 inch
  • Width: 898 mm, 35.3 inch
  • Depth: 2200 mm, 86.6 inch
  • Weight: View Part Number for Details.
Safety Warning

Full Product Description

The performance of high-powered lasers depends on effective cooling. High-powered lasers generate a significant amount of heat that must be removed from the laser system to avoid overheating critical components. Carbon dioxide (CO2) lasers, excimer lasers, ion lasers, solid-state lasers, and dye lasers all use liquid cooling to remove excess heat.

Laser liquid cooling can help accomplish three goals:
• Maintaining a precise laser wavelength and higher output efficiency

• Achieving desired beam quality

• Reducing thermal stress on a laser system.

Features
• Complete solution, easy to install and manage

• Non-ferrous hydraulic circuit including non-ferrous water tank

• A differential pressure switch ensures system shut down if the circuit runs dry.

• Maximum ambient temperature up to 48°C on standard units, tropicalization up to 53°C

• Use of compliant scroll compressors

• Low ambient speed-control

Benefits
• Compact design provides a space saving and easy to install solution

• High reliability and low energy consumption even in extreme ambient conditions

• Non-ferrous hydraulic circuit maintains the quality of the coolant ensuring stable working conditions, improved productivity and decreased maintenance costs.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.

Related Documents

×
Products Maximum Cooling Capacity Cooling Method Power Supply Voltage Pump Type Additional Protection Included Operating Environment Water Sensor Option Hydraulic Circuit Output Water Temperature Range
HLS076A4003501P000SSCLA000 76.0 kW @ 25°C (63°F) Air Cooled / Axial Fans 400V/3Ph/50Hz No Pump Without Antifreeze Low Ambient -10°C (Fan Step Control) No Low Water Stainless Steel With Tank Close Control +/- 0.5°C
HLS076A4003501P000SSCLA00A 76.0 kW @ 25°C (63°F) Air Cooled / Axial Fans 400V/3Ph/50Hz No Pump With Antifreeze Low Ambient -10°C (Fan Step Control) No Low Water Stainless Steel With Tank Close Control +/- 0.5°C
HLS076A4003501P30SSCLA000 76.0 kW @ 25°C (63°F) Air Cooled / Axial Fans 400V/3Ph/50Hz Single Pump 3 bar Without Antifreeze Low Ambient -10°C (Fan Step Control) No Low Water Stainless Steel With Tank Close Control +/- 0.5°C
HLS076A4003501P30SSCLA00A 76.0 kW @ 25°C (63°F) Air Cooled / Axial Fans 400V/3Ph/50Hz Single Pump 3 bar With Antifreeze Low Ambient -10°C (Fan Step Control) No Low Water Stainless Steel With Tank Close Control +/- 0.5°C
HLS076A4003501P50SSCLA00A 76.0 kW @ 25°C (63°F) Air Cooled / Axial Fans 400V/3Ph/50Hz Single Pump 5 bar With Antifreeze Low Ambient -10°C (Fan Step Control) No Low Water Stainless Steel With Tank Close Control +/- 0.5°C
HLS090A4003501P000SSCLA000 90.2 kW @ 25°C (63°F) Air Cooled / Axial Fans 400V/3Ph/50Hz No Pump Without Antifreeze Low Ambient -10°C (Fan Step Control) No Low Water Stainless Steel With Tank Close Control +/- 0.5°C
HLS090A4003501P000SSCLA00A 90.2 kW @ 25°C (63°F) Air Cooled / Axial Fans 400V/3Ph/50Hz No Pump With Antifreeze Low Ambient -10°C (Fan Step Control) No Low Water Stainless Steel With Tank Close Control +/- 0.5°C
HLS090A4003501P30SSCLA000 90.2 kW @ 25°C (63°F) Air Cooled / Axial Fans 400V/3Ph/50Hz Single Pump 3 bar Without Antifreeze Low Ambient -10°C (Fan Step Control) No Low Water Stainless Steel With Tank Close Control +/- 0.5°C
HLS090A4003501P30SSCLA00A 90.2 kW @ 25°C (63°F) Air Cooled / Axial Fans 400V/3Ph/50Hz Single Pump 3 bar With Antifreeze Low Ambient -10°C (Fan Step Control) No Low Water Stainless Steel With Tank Close Control +/- 0.5°C
HLS090A4003501P50SSCLA000 90.2 kW @ 25°C (63°F) Air Cooled / Axial Fans 400V/3Ph/50Hz Single Pump 5 bar Without Antifreeze Low Ambient -10°C (Fan Step Control) No Low Water Stainless Steel With Tank Close Control +/- 0.5°C
HLS090A4003501P50SSCLA00A 90.2 kW @ 25°C (63°F) Air Cooled / Axial Fans 400V/3Ph/50Hz Single Pump 5 bar With Antifreeze Low Ambient -10°C (Fan Step Control) No Low Water Stainless Steel With Tank Close Control +/- 0.5°C
HLS116A4003501P000SSCLA000 115.5 kW @ 25°C (63°F) Air Cooled / Axial Fans 400V/3Ph/50Hz No Pump Without Antifreeze Low Ambient -10°C (Fan Step Control) No Low Water Stainless Steel With Tank Close Control +/- 0.5°C
HLS116A4003501P000SSCLA00A 115.5 kW @ 25°C (63°F) Air Cooled / Axial Fans 400V/3Ph/50Hz No Pump With Antifreeze Low Ambient -10°C (Fan Step Control) No Low Water Stainless Steel With Tank Close Control +/- 0.5°C
HLS116A4003501P30SSCLA00A 115.5 kW @ 25°C (63°F) Air Cooled / Axial Fans 400V/3Ph/50Hz Single Pump 3 bar With Antifreeze Low Ambient -10°C (Fan Step Control) No Low Water Stainless Steel With Tank Close Control +/- 0.5°C
HLS116A4003501P50SSCLA00A 115.5 kW @ 25°C (63°F) Air Cooled / Axial Fans 400V/3Ph/50Hz Single Pump 5 bar With Antifreeze Low Ambient -10°C (Fan Step Control) No Low Water Stainless Steel With Tank Close Control +/- 0.5°C
HLS076A4003501P50SSCLA000 76.0 kW @ 25°C (63°F) Air Cooled / Axial Fans 400V/3Ph/50Hz Single Pump 5 bar Without Antifreeze Low Ambient -10°C (Fan Step Control) No Low Water Stainless Steel With Tank Close Control +/- 0.5°C
HLS116A4003501P30SSCLA000 115.5 kW @ 25°C (63°F) Air Cooled / Axial Fans 400V/3Ph/50Hz Single Pump 3 bar Without Antifreeze Low Ambient -10°C (Fan Step Control) No Low Water Stainless Steel With Tank Close Control +/- 0.5°C
HLS116A4003501P50SSCLA000 115.5 kW @ 25°C (63°F) Air Cooled / Axial Fans 400V/3Ph/50Hz Single Pump 5 bar Without Antifreeze Low Ambient -10°C (Fan Step Control) No Low Water Stainless Steel With Tank Close Control +/- 0.5°C

687466