High Pressure Steam Valves

High Pressure Steam Valves

Durable, high pressure, high flow steam valves for demanding hot water, and steam applications.

Technical Specifications

  • Division: Fluid Control Division
  • Valve Type: 2-Way
  • Function: Normally Closed
  • Media: Steam
  • Port Size: 3/8 - 1-1/14 inch
  • Port Type: NPT
  • Maximum Pressure Differential: Up to 125 psi
  • Maximum Steam Pressure: Up to 125 psi
  • Body Material: Brass
  • Seal Material: PTFE
  • Maximum Fluid Temperature: Up to 353 °F
  • Maximum Ambient Temperature: Up to 77 °F
  • Orifice Size: 5/8 - 1-1/8 inch
  • Main Flow Coefficient: 3.0 - 16.0 Cv
  • Specifications Met: UL, CSA, CE - Low Voltage, EMC
Safety Warning

Full Product Description

The unique piston style design of these high pressure, high flow steam valves deliver uptime and long life at elevated pressures and temperatures, where competive products fall flat. These time-tested valves are the “go to” solution for demanding steam applications.
Products Valve Type Function Media Port Size Port Type Actuation Type Minimum Pressure Differential Maximum Pressure Differential Maximum Steam Pressure Body Material Seal Material Maximum Fluid Temperature Maximum Ambient Temperature Orifice Size Main Flow Coefficient Input Voltage Power Consumption Coil Type Insulation Class Ingress Protection Rating Installation Preventive Maintenance Kit Specifications Met
73218BN3TTS0 2 Way Normally Closed Water, Hot Water, Steam 3/8 NPT Internally Piloted 3 - 125 Brass PTFE 353 77 5/8 3.0 Pressure Vessel Only 10 Requires Class H Coil from Chart 7 Requires Class H Coil from Chart 7 N/A IOM 7217 7K823 N/A
73218BN4UTS0 2 Way Normally Closed Water, Hot Water, Steam 1/2 NPT Internally Piloted 3 - 125 Brass PTFE 353 77 5/8 4.0 Pressure Vessel Only 10 Requires Class H Coil from Chart 7 Requires Class H Coil from Chart 7 N/A IOM 7217 7K823 N/A
73218BN4UTS0N0C222P3 2 Way Normally Closed Water, Hot Water, Steam 1/2 NPT Internally Piloted 3 - 125 Brass PTFE 353 77 5/8 4.0 120/60, 110/50 10 1/2" NPT Conduit w/ 18" Leads Class H NEMA 4,4X IOM 7217 7K823 UL, CSA Listed General Purpose Valve; CE - Low Voltage, EMC
73218BN4UTS0N0D200P3 2 Way Normally Closed Water, Hot Water, Steam 1/2 NPT Internally Piloted 3 - 125 Brass PTFE 353 77 5/8 4.0 120/60, 110/50 10 DIN 43650A / ISO 4400 Class H NEMA 4,4X IOM 7217 7K823 UL, CSA Listed General Purpose Valve; CE - Low Voltage, EMC
73218BN4UTS0N0H222P3 2 Way Normally Closed Water, Hot Water, Steam 1/2 NPT Internally Piloted 3 - 125 Brass PTFE 353 77 5/8 4.0 120/60, 110/50 10 1/2" NPT Conduit w/ 18" Leads Class H UL, CSA - Class 1, Div. 1, Group A,B,C,D Class 2, Div. 1, Group E,F,G - T3C IOM 7217 7K823 UL, CSA Listed General Purpose Valve for Hazardous Locations; CE - Low Voltage, EMC
73218BN5VTS0 2 Way Normally Closed Water, Hot Water, Steam 3/4 NPT Internally Piloted 3 - 125 Brass PTFE 353 77 5/8 4.5 Pressure Vessel Only 10 Requires Class H Coil from Chart 7 Requires Class H Coil from Chart 7 N/A IOM 7217 7K823 N/A
73218BN5VTS0N0C222P3 2 Way Normally Closed Water, Hot Water, Steam 3/4 NPT Internally Piloted 3 - 125 Brass PTFE 353 77 5/8 4.5 120/60, 110/50 10 1/2" NPT Conduit w/ 18" Leads Class H NEMA 4,4X IOM 7217 7K823 UL, CSA Listed General Purpose Valve; CE - Low Voltage, EMC
73218BN5VTS0N0D200B2 2 Way Normally Closed Water, Hot Water, Steam 3/4 NPT Internally Piloted 3 - 125 Brass PTFE 353 77 5/8 4.5 120/60, 110/50 10 DIN 43650A / ISO 4400 Class H NEMA 4,4X IOM 7217 7K823 UL, CSA Listed General Purpose Valve; CE - Low Voltage, EMC
73218BN5VTS0N0H222P3 2 Way Normally Closed Water, Hot Water, Steam 3/4 NPT Internally Piloted 3 - 125 Brass PTFE 353 77 5/8 4.5 120/60, 110/50 10 1/2" NPT Conduit w/ 18" Leads Class H UL, CSA - Class 1, Div. 1, Group A,B,C,D Class 2, Div. 1, Group E,F,G - T3C IOM 7217 7K823 UL, CSA Listed General Purpose Valve for Hazardous Locations; CE - Low Voltage, EMC
73218BN64TS0 2 Way Normally Closed Water, Hot Water, Steam 1 NPT Internally Piloted 5 - 125 Brass PTFE 353 77 1-1/16 13.5 Pressure Vessel Only 10 Requires Class H Coil from Chart 7 Requires Class H Coil from Chart 7 N/A IOM 7217 7K824 N/A
73218BN64TS0N0C222P3 2 Way Normally Closed Water, Hot Water, Steam 1 NPT Internally Piloted 5 - 125 Brass PTFE 353 77 1-1/16 13.5 120/60, 110/50 10 1/2" NPT Conduit w/ 18" Leads Class H NEMA 4,4X IOM 7217 7K824 UL, CSA Listed General Purpose Valve; CE - Low Voltage, EMC
73218BN64TS0N0D200Q3 2 Way Normally Closed Water, Hot Water, Steam 1 NPT Internally Piloted 5 - 125 Brass PTFE 353 77 1-1/16 13.5 120/60, 110/50 10 DIN 43650A / ISO 4400 Class H NEMA 4,4X IOM 7217 7K824 UL, CSA Listed General Purpose Valve; CE - Low Voltage, EMC
73218BN64TS0N0H222Q3 2 Way Normally Closed Water, Hot Water, Steam 1 NPT Internally Piloted 5 - 125 Brass PTFE 353 77 1-1/16 13.5 120/60, 110/50 10 1/2" NPT Conduit w/ 18" Leads Class H UL, CSA - Class 1, Div. 1, Group A,B,C,D Class 2, Div. 1, Group E,F,G - T3C IOM 7217 7K824 UL, CSA Listed General Purpose Valve for Hazardous Locations; CE - Low Voltage, EMC
73218BN75TS0 2 Way Normally Closed Water, Hot Water, Steam 1-1/4 NPT Internally Piloted 5 - 125 Brass PTFE 353 77 1-1/8 16.0 Pressure Vessel Only 10 Requires Class H Coil from Chart 7 Requires Class H Coil from Chart 7 N/A IOM 7217 7K824 N/A
73218BN75TS0N0C222P3 2 Way Normally Closed Water, Hot Water, Steam 1-1/4 NPT Internally Piloted 5 - 125 Brass PTFE 353 77 1-1/8 16.0 120/60, 110/50 10 1/2" NPT Conduit w/ 18" Leads Class H NEMA 4,4X IOM 7217 7K824 UL, CSA Listed General Purpose Valve; CE - Low Voltage, EMC
73218BN75TS0N0D200P3 2 Way Normally Closed Water, Hot Water, Steam 1-1/4 NPT Internally Piloted 5 - 125 Brass PTFE 353 77 1-1/8 16.0 120/60, 110/50 10 DIN 43650A / ISO 4400 Class H NEMA 4,4X IOM 7217 7K824 UL, CSA Listed General Purpose Valve; CE - Low Voltage, EMC
73218BN75TS0N0H222P3 2 Way Normally Closed Water, Hot Water, Steam 1-1/4 NPT Internally Piloted 5 - 125 Brass PTFE 353 77 1-1/8 16.0 120/60, 110/50 10 1/2" NPT Conduit w/ 18" Leads Class H UL, CSA - Class 1, Div. 1, Group A,B,C,D Class 2, Div. 1, Group E,F,G - T3C IOM 7217 7K824 UL, CSA Listed General Purpose Valve for Hazardous Locations; CE - Low Voltage, EMC