F Series Solenoid Valves for Industrial and Process applications | Product Series

Filter by

    No filters selected

Specifications Met

Body Material

Orifice Size

Power Supply Voltage

Valve Type

Media

Seal Material

Maximum Operating Pressure

Coil Specifications Met

Flow Coefficient 1

Function

Maximum Fluid Temperature

Get your Parker account Today!

Create one account to manage everything you do with Parker, from your shopping preferences to your application access.


LOADING IMAGES
F Series Solenoid Valves for Industrial and Process applications

F Series Solenoid Valves for Industrial and Process applications

F Series is a full range of direct operated solenoid valves, available in 2 way and 3 way configurations, offering many sealing materials and different flow rates.

Technical Specifications

  • Actuation Type: Direct Acting
  • Port Size: 32 x 32 mm
  • Port Type: Sub-base (Flanged), -
  • Seat Material: Stainless Steel, POM, -, Brass
  • Exhaust Orifice Size: -, 2,5 mm, 1,5 mm, 2,0 mm, 1,0 mm
  • Flow Coefficient 2: 0,21 m3/h, 0,27 m3/h, 0,15 m3/h, 0,13 m3/h, 0,08 m3/h, 0,11 m3/h, 0,09 m3/h, 0,12 m3/h, -, 1,5 m3/h, 0,04 m3/h
  • Minimum Operating Pressure: 0 bar
  • Minimum Fluid Temperature: -30 °C, -10 °C, -25 °C, 0 °C, -20 °C, -10 °c
  • Coil Power Consumption: -, 9W, 19W, 14W, 8W, 11W, 0.3W to 2.3W
  • Electrical Connection: -, 2 P + E plug according to EN 175301-803 type A, Screw Terminals - Metallic Housing, Screw Terminals - Metallic Housing with M20 connection, Screw terminals, Screw Terminals, Cable connection through a stainless steel cable gland M20 x 1.5 allowing use
  • Coil Temperature Range: -, -40°C +50°C, -40°C +65°C, -50 +80°C / +60°C / +40°C
  • Insulation Class: -, H (180 °C), F (155 °C)
  • ATEX Specifications Met: -, II 1 G - Ex ia IIC - T6, II 2 G - Ex db IIC T4 / T5 / T6
Safety Warning

Full Product Description

The F Series direct operated solenoid valves includes many options to fullfill the demand of the most challenging applications in Industrial and Process markets. The solid and robust design includes a stainless steel operator rated for million of life cycles. This product solution can optimize the total ownership costs in a broad range of heavy duty and high demanding applications. Typicals are: compressors and air treatment, fluids & gas control/handling, actuators control in safe or harsh environment including ATEX, water and steam control. Flange interface makes these valves extremely easy to assemble, dismount, replace.

Markets:
- Industrial
- Process

Applications:
- Compressors and air treatment
- Fluid and gas control
- Actuator control
- Water and steam control

Features/Benefits:
- Compact
- Easy to assemble, dismount, replace
- Coil modularity including ATEX

Related Documents

Literature and Reference Materials
Parker--General Catalogue--0112UK
Product Demos & Tutorials
Solenoid Valves Overview Video
×
Products Specifications Met Body Material Orifice Size Power Supply Voltage Valve Type Media Seal Material Maximum Operating Pressure Coil Specifications Met Flow Coefficient 1 Function Maximum Fluid Temperature
121F2523-852023-483824P8 DIN-EN-ISO 23553-1 (2009-10) approved for oil burners CW 617N UNI EN 12165 14,0 mm 115V 50Hz - 120V 60Hz 2/2 Way Oils FKM 30 bar CE - UKCA 25 l/min Normally Closed 160°C
121F2523-876024-483824P8 DIN-EN-ISO 23553-1 (2009-10) approved for oil burners 14,0 mm 115V 50Hz - 120V 60Hz 2/2 Way Oils FKM 30 bar CE - UKCA 25 l/min Normally Closed 160°C
121F4606-2995-492453C2 - CW 617N UNI EN 12165 2,0 mm 24V DC 2/2 Way Air, Inert gases, Neutral liquids FKM 10 bar CE - UKCA 2,2 l/min Normally Closed 100 °C
121F47 - CW 617N UNI EN 12165 2,5 mm - 2/2 Way Air, Inert gases, Neutral liquids PCTFE 50 bar AC - 22 bar DC - 3,5 l/min Normally Closed 75 °C
121F63-2995 - CW 617N UNI EN 12165 2,5 mm - 2/2 Way Hydraulic Oils, Neutral Liquids Ruby 50 bar AC - 22 bar DC - 3,5 l/min Normally Closed 130 °C
121F6321-299521-492425F4 TÜV Approved CW 617N UNI EN 12165 3,0 mm 230V 50Hz 2/2 Way Oils Ruby 30 bar CE - UKCA 4,5 l/min Normally Closed 140 °C
121F64 - CW 617N UNI EN 12165 3,0 mm - 2/2 Way Hydraulic Oils, Neutral Liquids Ruby 36 bar AC - 15 bar DC - 4,5 l/min Normally Closed 130 °C
121F64-2995 - CW 617N UNI EN 12165 3,0 mm - 2/2 Way Hydraulic Oils, Neutral Liquids Ruby 36 bar AC - 15 bar DC - 4,5 l/min Normally Closed 130 °C
121F67 - CW 617N UNI EN 12165 1,5 mm - 2/2 Way Hydraulic Oils, Neutral Liquids Ruby 100 bar AC - 55 bar DC - 1,5 l/min Normally Closed 130 °C
121FS8052-2995-481865C2 Degreased CW 617N UNI EN 12165 3,0 mm 24V DC 2/2 Way Air, Inert gases, industrial oxygen FKM 7 bar CE - UKCA - VDE 4,5 l/min Normally Closed 100 °C
122F44 - CW 617N UNI EN 12165 1,5 mm - 2/2 Way Air, Inert gases, Neutral liquids FKM 20 bar AC/DC - 1,5 l/min Normally Open 120 °C
122F44-2995-481865C2 - CW 617N UNI EN 12165 1,5 mm 24V DC 2/2 Way Air, Inert gases, Neutral liquids FKM 20 bar CE - UKCA - VDE 1,5 l/min Normally Open 100 °C
122F44-4270-481000C1 - CW 617N UNI EN 12165 1,5 mm 12V DC 2/2 Way Air, Inert gases, Neutral liquids FKM 20 bar CE - UKCA 1,5 l/min Normally Open 120 °C
131F4490 Intrinsically Safe CW 617N UNI EN 12165 1,0 mm - 3/2 Way Air, Inert gases, Neutral liquids FKM 10 bar DC - 0,6 l/min Normally Closed 75 °C
131F4497 For low power coils CW 617N UNI EN 12165 1,5 mm - 3/2 Way Air, Inert gases, Neutral liquids PUR 7 bar AC/DC - 1,5 l/min Normally Closed 75 °C
131F46 - CW 617N UNI EN 12165 2,0 mm - 3/2 Way Air, Inert gases, Neutral liquids FKM 10 bar AC/DC - 2,5 l/min Normally Closed 120 °C
131F46-2995 - CW 617N UNI EN 12165 2,0 mm - 3/2 Way Air, Inert gases, Neutral liquids FKM 10 bar AC/DC - 2,5 l/min Normally Closed 120 °C
131F46-2995-481865C2 - CW 617N UNI EN 12165 2,0 mm 24V DC 3/2 Way Air, Inert gases, Neutral liquids FKM 10 bar CE - UKCA - VDE 2,5 l/min Normally Closed 100 °C
131F4650 Manual Override CW 617N UNI EN 12165 2,0 mm - 3/2 Way Air, Inert gases, Neutral liquids FKM 10 bar AC/DC - 2,5 l/min Normally Closed 120 °C
131F5406 - Stainless Steel 1,5 mm - 3/2 Way Air, Inert gases, Neutral liquids FKM 15 bar AC/DC - 1,5 l/min Normally Closed 100 °c
132F43 - CW 617N UNI EN 12165 2,5 mm - 3/2 Way Air, Inert gases, Neutral liquids FKM 7 bar AC/DC - 2,2 l/min Normally Open 75 °C
132F43-2995-481865C2 - CW 617N UNI EN 12165 2,5 mm 24V DC 3/2 Way Air, Inert gases, Neutral liquids FKM 7 bar CE - UKCA - VDE 2,2 l/min Normally Open 75 °C
132F44 - CW 617N UNI EN 12165 1,5 mm - 3/2 Way Air, Inert gases, Neutral liquids FKM 15 bar AC/DC - 1,4 l/min Normally Open 75 °C
132F46 - CW 617N UNI EN 12165 2,0 mm - 3/2 Way Air, Inert gases, Neutral liquids FKM 10 bar AC/DC - 1,8 l/min Normally Open 120 °C
132F46-2995 - CW 617N UNI EN 12165 2,0 mm - 3/2 Way Air, Inert gases, Neutral liquids FKM 10 bar AC/DC - 1,8 l/min Normally Open 120 °C
133F46 - CW 617N UNI EN 12165 2,0 mm - 3/2 Way Air, Inert gases, Neutral liquids FKM 7 bar AC/DC - 2,5 l/min Universal 120 °C
133F5408-2995 - Stainless Steel 1,5 mm - 3/2 Way Refrigerants Ruby 12 bar AC - 1,5 l/min Universal 100 °C
E121F43 - CW 617N UNI EN 12165 3,0 mm - 2/2 Way Air, Inert gases, Neutral liquids PCTFE 36 bar AC - 15 bar DC - 4,5 l/min Normally Closed 75 °C
E121F43-2995-481865C2 - CW 617N UNI EN 12165 3,0 mm 24V DC 2/2 Way Air, Inert gases, Neutral liquids PCTFE 7 bar CE - UKCA - VDE 4,5 l/min Normally Closed 75 °C
E121F4302 - CW 617N UNI EN 12165 3,0 mm - 2/2 Way Air, Inert gases, Neutral liquids FKM 10 bar AC/DC - 4,5 l/min Normally Closed 120 °C
E121F44 - CW 617N UNI EN 12165 1,5 mm - 2/2 Way Air, Inert gases, Neutral liquids PCTFE 70 bar AC - 55 bar DC - 1,5 l/min Normally Closed 75 °C
E121F44-4270-486265C2 - CW 617N UNI EN 12165 1,5 mm 24V DC 2/2 Way Air, Inert gases, Neutral liquids PCTFE 55 bar CE - UKCA 1,5 l/min Normally Closed 75 °C
E121F4406 - CW 617N UNI EN 12165 1,5 mm - 2/2 Way Air, Inert gases, Neutral liquids FKM 20 bar AC/DC - 1,5 l/min Normally Closed 120 °C
E121F4406-2995-481865C2 - CW 617N UNI EN 12165 1,5 mm 24V DC 2/2 Way Air, Inert gases, Neutral liquids FKM 20 bar CE - UKCA - VDE 1,5 l/min Normally Closed 100 °C
E131F26 Manual Override POM 2,0 mm - 3/2 Way Air, Inert Gases FKM 10 bar AC/DC - 2 l/min Normally Closed 50 °C
E131F26-2995-481865C2 Manual Override POM 2,0 mm 24V DC 3/2 Way Air, Inert Gases FKM 10 bar CE - UKCA - VDE 2 l/min Normally Closed 50 °C
E131F43 - CW 617N UNI EN 12165 2,5 mm - 3/2 Way Air, Inert gases, Neutral liquids FKM 7 bar AC/DC - 3,5 l/min Normally Closed 120 °C
E131F43-2995 - CW 617N UNI EN 12165 2,5 mm - 3/2 Way Air, Inert gases, Neutral liquids FKM 7 bar AC/DC - 3,5 l/min Normally Closed 120 °C
E131F43-2995-481865C2 - CW 617N UNI EN 12165 2,5 mm 24V DC 3/2 Way Air, Inert gases, Neutral liquids FKM 7 bar CE - UKCA - VDE 3,5 l/min Normally Closed 100 °C
E131F4350 Manual Override CW 617N UNI EN 12165 2,5 mm - 3/2 Way Air, Inert gases, Neutral liquids FKM 7 bar AC/DC - 3,5 l/min Normally Closed 120 °C
E131F44 - CW 617N UNI EN 12165 1,5 mm - 3/2 Way Air, Inert gases, Neutral liquids FKM 15 bar AC/DC - 1,5 l/min Normally Closed 120 °C
E131F44-2995-481865C2 - CW 617N UNI EN 12165 1,5 mm 24V DC 3/2 Way Air, Inert gases, Neutral liquids FKM 15 bar CE - UKCA - VDE 1,5 l/min Normally Closed 100 °C
E131F44-2995-483510S6 - CW 617N UNI EN 12165 1,5 mm 220-240V 50Hz - 240V 60Hz 3/2 Way Air, Inert gases, Neutral liquids FKM 15 bar CE - UKCA - VDE 1,5 l/min Normally Closed 100 °C
E131F44-299503-491514P3 - CW 617N UNI EN 12165 1,5 mm 110V 50Hz - 120V 60Hz 3/2 Way Air, Inert gases, Neutral liquids FKM 15 bar CE - UCKA - UL - VDE 1,5 l/min Normally Closed 100 °C
E131F4450 Manual Override CW 617N UNI EN 12165 1,5 mm - 3/2 Way Air, Inert gases, Neutral liquids FKM 15 bar AC/DC - 1,5 l/min Normally Closed 100 °C
E133F43 - CW 617N UNI EN 12165 2,5 mm - 3/2 Way Air, Inert gases, Neutral liquids FKM 4 bar AC/DC - 3,5 l/min Universal 120 °C
E133F43-2995-481865C2 - CW 617N UNI EN 12165 2,5 mm 24V DC 3/2 Way Air, Inert gases, Neutral liquids FKM 10 bar CE - UKCA - VDE 3,5 l/min Universal 100 °C
E133F44 - CW 617N UNI EN 12165 1,5 mm - 3/2 Way Air, Inert gases, Neutral liquids FKM 10 bar AC/DC - 1,5 l/min Universal 120 °C
U131F5694 Without body - Pilot Only - - - 3/2 Way Air, Inert Gases PUR 14 bar AC/DC (with 2,0 mm orifice) - 3,5 l/min Normally Closed 75 °C
U131F5694-49296501N7 Without body - Pilot Only - - 28V DC 3/2 Way Air, Inert Gases PUR 14 bar (with 2,0 mm orifice) CE - UKCA 3,5 l/min Normally Closed 65 °C
U131F5695 - Stainless Steel 2,5 mm - 3/2 Way Air, Inert Gases FKM 12 bar AC/DC - 3,5 l/min Normally Closed 65 °C
U131F5695-49296501N7 - Stainless Steel 2,5 mm 28V DC 3/2 Way Air, Inert Gases FKM 12 bar CE - UKCA 3,5 l/min Normally Closed 65 °C
U131F7695 - Stainless Steel 2,5 mm - 3/2 Way Air, Inert Gases FKM 12 bar AC/DC - 3,5 l/min Normally Closed 75 °C
U131F7695-497105C2 - Stainless Steel 2,5 mm 24V DC 3/2 Way Air, Inert Gases FKM 12 bar CE - UKCA 3,5 l/min Normally Closed 75 °C
121F4606-2995-481865C2 - CW 617N UNI EN 12165 2,0 mm 24V DC 2/2 Way Air, Inert gases, Neutral liquids FKM 10 bar CE - UCKA - UL - VDE 2,2 l/min Normally Closed 100 °C
E121F4302-2995-481865C2 CW 617N UNI EN 12165 3,0 mm 24V DC 2/2 Way Air, Inert gases, Neutral liquids FKM 7 bar CE - UCKA - UL - VDE 4,5 l/min Normally Closed 100 °C
E121F44-2995-481865T7 CW 617N UNI EN 12166 1,5 mm 100V 50Hz - 100-120V/60Hz 2/2 Way Air, Inert gases, Neutral liquids PCTFE 60 bar CE - UKCA - VDE 1,5 l/min Normally Closed 75 °C

687466
A18171