var attrArray = new Array();
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector DT04-2P ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B32K ';
attrValueMap['Flow Rate'] = '30 / 15 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01M ';
attrValueMap['Flow Rate'] = '40 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.5 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01M ';
attrValueMap['Flow Rate'] = '40 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01M ';
attrValueMap['Flow Rate'] = '40 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01M ';
attrValueMap['Flow Rate'] = '40 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01M ';
attrValueMap['Flow Rate'] = '40 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '24 V / 1.5 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01M ';
attrValueMap['Flow Rate'] = '40 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01S ';
attrValueMap['Flow Rate'] = '60 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.5 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01S ';
attrValueMap['Flow Rate'] = '60 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01S ';
attrValueMap['Flow Rate'] = '60 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01S ';
attrValueMap['Flow Rate'] = '60 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '24 V / 1.5 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01S ';
attrValueMap['Flow Rate'] = '60 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01S ';
attrValueMap['Flow Rate'] = '60 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '24 V / 1.5 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01S ';
attrValueMap['Flow Rate'] = '60 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01S ';
attrValueMap['Flow Rate'] = '60 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01U ';
attrValueMap['Flow Rate'] = '80 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.5 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector DT04-2P ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.2 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.2 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '12 V / 2.2 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '12 V / 2.2 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01K ';
attrValueMap['Flow Rate'] = '30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.15 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01K ';
attrValueMap['Flow Rate'] = '30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01K ';
attrValueMap['Flow Rate'] = '30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.3 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01K ';
attrValueMap['Flow Rate'] = '30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.2 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01K ';
attrValueMap['Flow Rate'] = '30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01U ';
attrValueMap['Flow Rate'] = '80 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01U ';
attrValueMap['Flow Rate'] = '80 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '24 V / 1.5 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01U ';
attrValueMap['Flow Rate'] = '80 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01U ';
attrValueMap['Flow Rate'] = '80 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02M ';
attrValueMap['Flow Rate'] = '40 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.5 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02M ';
attrValueMap['Flow Rate'] = '40 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02M ';
attrValueMap['Flow Rate'] = '40 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02M ';
attrValueMap['Flow Rate'] = '40 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '24 V / 1.5 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02M ';
attrValueMap['Flow Rate'] = '40 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02M ';
attrValueMap['Flow Rate'] = '40 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '24 V / 1.5 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02M ';
attrValueMap['Flow Rate'] = '40 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02M ';
attrValueMap['Flow Rate'] = '40 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02S ';
attrValueMap['Flow Rate'] = '60 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.5 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02S ';
attrValueMap['Flow Rate'] = '60 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02S ';
attrValueMap['Flow Rate'] = '60 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02S ';
attrValueMap['Flow Rate'] = '60 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '24 V / 1.5 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02S ';
attrValueMap['Flow Rate'] = '60 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector DT04-2P ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02F ';
attrValueMap['Flow Rate'] = '10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.2 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02F ';
attrValueMap['Flow Rate'] = '10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.2 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02F ';
attrValueMap['Flow Rate'] = '12 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02F ';
attrValueMap['Flow Rate'] = '12 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.15 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector DT04-2P ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector DT04-2P ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.2 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.2 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02S ';
attrValueMap['Flow Rate'] = '60 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02S ';
attrValueMap['Flow Rate'] = '60 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02U ';
attrValueMap['Flow Rate'] = '80 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.5 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02U ';
attrValueMap['Flow Rate'] = '80 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02U ';
attrValueMap['Flow Rate'] = '80 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02U ';
attrValueMap['Flow Rate'] = '80 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '24 V / 1.5 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01K ';
attrValueMap['Flow Rate'] = '30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '12 V / 2.2 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01K ';
attrValueMap['Flow Rate'] = '30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01K ';
attrValueMap['Flow Rate'] = '30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '12 V / 2.2 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02C ';
attrValueMap['Flow Rate'] = '6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02C ';
attrValueMap['Flow Rate'] = '6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02C ';
attrValueMap['Flow Rate'] = '6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02F ';
attrValueMap['Flow Rate'] = '12 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.15 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02F ';
attrValueMap['Flow Rate'] = '10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.15 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector DT04-2P ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02F ';
attrValueMap['Flow Rate'] = '10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02F ';
attrValueMap['Flow Rate'] = '12 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02F ';
attrValueMap['Flow Rate'] = '10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '12 V / 2.2 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02K ';
attrValueMap['Flow Rate'] = '30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.15 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02K ';
attrValueMap['Flow Rate'] = '30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02K ';
attrValueMap['Flow Rate'] = '30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.3 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02K ';
attrValueMap['Flow Rate'] = '30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.2 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02K ';
attrValueMap['Flow Rate'] = '30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '24 V / 1.15 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02K ';
attrValueMap['Flow Rate'] = '30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02K ';
attrValueMap['Flow Rate'] = '30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '12 V / 2.2 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E03F ';
attrValueMap['Flow Rate'] = '12 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E03H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E03H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E03H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Zerolap ';
attrValueMap['Spool Code'] = 'E50F ';
attrValueMap['Flow Rate'] = '5 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Zerolap ';
attrValueMap['Spool Code'] = 'E50H ';
attrValueMap['Flow Rate'] = '8 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Zerolap ';
attrValueMap['Spool Code'] = 'E50H ';
attrValueMap['Flow Rate'] = '8 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B31M ';
attrValueMap['Flow Rate'] = '40 / 20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B31S ';
attrValueMap['Flow Rate'] = '60 / 30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B32M ';
attrValueMap['Flow Rate'] = '40 / 20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B32S ';
attrValueMap['Flow Rate'] = '60 / 30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B32U ';
attrValueMap['Flow Rate'] = '80 / 40 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.5 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B31F ';
attrValueMap['Flow Rate'] = '12 / 6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B31F ';
attrValueMap['Flow Rate'] = '12 / 6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.3 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B31F ';
attrValueMap['Flow Rate'] = '12 / 6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B31F ';
attrValueMap['Flow Rate'] = '12 / 6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B31H ';
attrValueMap['Flow Rate'] = '20 / 10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B31H ';
attrValueMap['Flow Rate'] = '20 / 10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.2 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B31H ';
attrValueMap['Flow Rate'] = '20 / 10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B31H ';
attrValueMap['Flow Rate'] = '20 / 10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B32F ';
attrValueMap['Flow Rate'] = '12 / 6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B32F ';
attrValueMap['Flow Rate'] = '12 / 6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B32H ';
attrValueMap['Flow Rate'] = '20 / 10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B32H ';
attrValueMap['Flow Rate'] = '20 / 10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Zerolap ';
attrValueMap['Spool Code'] = 'B60H ';
attrValueMap['Flow Rate'] = '8 / 4 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01C ';
attrValueMap['Flow Rate'] = '6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01C ';
attrValueMap['Flow Rate'] = '6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01C ';
attrValueMap['Flow Rate'] = '6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01C ';
attrValueMap['Flow Rate'] = '6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01C ';
attrValueMap['Flow Rate'] = '6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01F ';
attrValueMap['Flow Rate'] = '10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.15 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector DT04-2P ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01F ';
attrValueMap['Flow Rate'] = '10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01F ';
attrValueMap['Flow Rate'] = '12 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01F ';
attrValueMap['Flow Rate'] = '10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01F ';
attrValueMap['Flow Rate'] = '10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.2 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01F ';
attrValueMap['Flow Rate'] = '12 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01F ';
attrValueMap['Flow Rate'] = '12 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01F ';
attrValueMap['Flow Rate'] = '10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01F ';
attrValueMap['Flow Rate'] = '10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '12 V / 2.2 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01F ';
attrValueMap['Flow Rate'] = '12 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01F ';
attrValueMap['Flow Rate'] = '12 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01F ';
attrValueMap['Flow Rate'] = '10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01F ';
attrValueMap['Flow Rate'] = '12 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.15 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector DT04-2P ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector DT04-2P ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01F ';
attrValueMap['Flow Rate'] = '10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.2 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '24 V / 1.15 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector DT04-2P ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01K ';
attrValueMap['Flow Rate'] = '30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02C ';
attrValueMap['Flow Rate'] = '6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B32S ';
attrValueMap['Flow Rate'] = '60 / 30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.5 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01M ';
attrValueMap['Flow Rate'] = '40 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '24 V / 1.5 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02U ';
attrValueMap['Flow Rate'] = '80 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '24 V / 1.5 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Solenoid Option'] = '12 V / 2.3 A ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Spool Code'] = 'E01C ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Flow Rate'] = '6 L/MIN ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Code'] = 'E02C ';
attrValueMap['Flow Rate'] = '6 L/MIN ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Spool Design'] = 'Spool/body ';
attrValueMap['Solenoid Option'] = '24 V / 1.5 A ';
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Flow Rate'] = '60 / 30 L/MIN ';
attrValueMap['Spool Code'] = 'B31S ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B32S ';
attrValueMap['Flow Rate'] = '60 / 30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '12 V / 2.2 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02K ';
attrValueMap['Flow Rate'] = '30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E03C ';
attrValueMap['Flow Rate'] = '6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E03F ';
attrValueMap['Flow Rate'] = '12 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.15 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E03F ';
attrValueMap['Flow Rate'] = '12 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E03F ';
attrValueMap['Flow Rate'] = '12 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector DT04-2P ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02C ';
attrValueMap['Flow Rate'] = '6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B32H ';
attrValueMap['Flow Rate'] = '20 / 10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector DT04-2P ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01C ';
attrValueMap['Flow Rate'] = '6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E03H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Zerolap ';
attrValueMap['Spool Code'] = 'E50C ';
attrValueMap['Flow Rate'] = '6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Zerolap ';
attrValueMap['Spool Code'] = 'E50C ';
attrValueMap['Flow Rate'] = '6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B32F ';
attrValueMap['Flow Rate'] = '12 / 6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector DT04-2P ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02C ';
attrValueMap['Flow Rate'] = '6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01C ';
attrValueMap['Flow Rate'] = '6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '24 V / 1.15 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01F ';
attrValueMap['Flow Rate'] = '10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.3 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector DT04-2P ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01F ';
attrValueMap['Flow Rate'] = '12 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01F ';
attrValueMap['Flow Rate'] = '12 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '24 V / 1.15 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01F ';
attrValueMap['Flow Rate'] = '10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '24 V / 1.15 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01S ';
attrValueMap['Flow Rate'] = '60 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02M ';
attrValueMap['Flow Rate'] = '40 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01F ';
attrValueMap['Flow Rate'] = '10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '12 V / 2.3 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01F ';
attrValueMap['Flow Rate'] = '10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '12 V / 2.2 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '24 V / 1.15 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector DT04-2P ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02F ';
attrValueMap['Flow Rate'] = '12 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02F ';
attrValueMap['Flow Rate'] = '12 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '24 V / 1.15 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02F ';
attrValueMap['Flow Rate'] = '12 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02F ';
attrValueMap['Flow Rate'] = '10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02H ';
attrValueMap['Flow Rate'] = '20 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.15 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B32F ';
attrValueMap['Flow Rate'] = '12 / 6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.15 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B31F ';
attrValueMap['Flow Rate'] = '12 / 6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B31F ';
attrValueMap['Flow Rate'] = '12 / 6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B31F ';
attrValueMap['Flow Rate'] = '12 / 6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B32K ';
attrValueMap['Flow Rate'] = '30 / 15 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01C ';
attrValueMap['Flow Rate'] = '6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.15 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01C ';
attrValueMap['Flow Rate'] = '6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01F ';
attrValueMap['Flow Rate'] = '10 L /MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.15 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01F ';
attrValueMap['Flow Rate'] = '12 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '24 V / 1.15 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector DT04-2P ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01K ';
attrValueMap['Flow Rate'] = '30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '12 V / 2.2 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector DT04-2P ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01K ';
attrValueMap['Flow Rate'] = '30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02F ';
attrValueMap['Flow Rate'] = '10 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '12 V / 2.2 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector DT04-2P ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02K ';
attrValueMap['Flow Rate'] = '30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.1 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02K ';
attrValueMap['Flow Rate'] = '30 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '12 V / 2.2 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E03C ';
attrValueMap['Flow Rate'] = '6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 0.8 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E03C ';
attrValueMap['Flow Rate'] = '6 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '9 V / 2.7 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'B31U ';
attrValueMap['Flow Rate'] = '80 / 40 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Option'] = '24 V / 1.5 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01M ';
attrValueMap['Flow Rate'] = '40 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01M ';
attrValueMap['Flow Rate'] = '40 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Design'] = 'Spool/sleeve ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E01U ';
attrValueMap['Flow Rate'] = '80 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '24 V / 1.5 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Spool Code'] = 'E02S ';
attrValueMap['Flow Rate'] = '60 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Solenoid Option'] = '24 V / 1.5 A ';
attrValueMap['Spool Design'] = 'Spool/body ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Spool Design'] = 'Spool/body ';
attrValueMap['Port Connection'] = 'NG06 / CETOP 03 ';
attrValueMap['Spool Code'] = 'B32K ';
attrValueMap['Solenoid Option'] = '24 V / 1.15 A ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Flow Rate'] = '30 / 15 L/MIN ';
attrValueMap['Spool Position'] = 'Operated in position a or b ';
attrValueMap['Solenoid Connection'] = 'Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity ';
attrArray.push(attrValueMap);
var attrValueMap = {};
attrValueMap['Spool Design'] = 'Spool/body ';
attrValueMap['Port Connection'] = 'NG10 / CETOP 05 ';
attrValueMap['Spool Code'] = 'E02U ';
attrValueMap['Flow Rate'] = '80 L/MIN ';
attrValueMap['Solenoid Option'] = '12 V / 2.95 A ';
attrValueMap['Spool Position'] = 'Operated in position b ';
attrValueMap['Spool Type'] = 'Overlap ';
attrValueMap['Solenoid Connection'] = 'Connector as per EN 175301-803 ';
attrArray.push(attrValueMap);
Parker's proven direct operated proportional DC valves series D1FB (NG06) / D3FB (NG10) are universally applicable, provide high repeatability and low hysteresis. The D1FB*EE with explosion proof solenoids allows the usage in hazardous environments.
Technical Specifications
Operation Type:
Direct
Electronics Type:
External
Pressure Differential:
5 bar
Function:
2-way, 3-way
Actuation Type:
Proportional solenoid
Seal Material:
NBR
Mounting Type:
Subplate mounting
Mounting Position:
Unrestricted
Maximum Flow Rate:
N/A
Maximum Operating Pressure:
350 bar
Maximum Operating Temperature:
60 (explosion-proof: 40) Ā°C
Minimum Operating Temperature:
-20 Ā°C
For Fluid Type:
Hydraulic oil according to DIN 51524 ... 535
Weight:
D1FB: 2.2, D1FB*EE with one solenoid: 2.5, D1FB*EE with two solenoids: 3.5, D3FB: 6.5 kg
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.....
Click here to view all product safety information.
Full Product Description
The direct operated valves D1FB (NG06) and D3FB (NG10) are universally applicable, provide high repeatability and low hysteresis for an improved process accuracy.
D1FB and D3FB represent Parker's experience in proportional DC valve technology. They are sutiable for use in applications which require a speed control. Both can be ordered with spool/sleeve design (D*FB*0) for maximum precision as well as spool/body design (D*FB*3) for high nominal flow. The parameters can be saved, changed and duplicated in combination with the digital power amplifier PWD00A-400.
The D1FB*EE series with explosion proof solenoids is based on the standard D1FB series. The specific solenoid design allows the usage in hazardous environments. The explosion proof class is Ex e mb II T4 Gb for use in zone 1 and 2 (conform to ATEX). Additionally the solenoids have IECEx conformity.
Features/Benefits:
ā¢ Spool/sleeve and spool/body design - provides versatile applications, for maximum precision or high nominal flow
ā¢ Manual override - allows to actuate the valve without current
ā¢ Low hysteresis - ensures high repeatability and thus improved process and product accuracy
ā¢ High level of dynamics and flows - optimized process speed
ā¢ Short delivery time - no storage necessary
ā¢ D1FB*EE only: optional coil to permit ambient temperature up to +60 Ā°C, modification XG371
Applications:
ā¢ Suitable for various hydraulic applications
ā¢ Machine tool
ā¢ Tire presses