CDAS HL/LE 100-170 Large Flow Heatless Regeneration Compressed Air Treatment System CDAS HL/LE 100-170 Large Flow Heatless Regeneration Compressed Air Treatment System CDAS HL/LE 100-170 Large Flow Heatless Regeneration Compressed Air Treatment System CDAS HL/LE 100-170 Large Flow Heatless Regeneration Compressed Air Treatment System CDAS HL/LE 100-170 Large Flow Heatless Regeneration Compressed Air Treatment System CDAS HL/LE 100-170 Large Flow Heatless Regeneration Compressed Air Treatment System

CDAS HL/LE 100-170 Large Flow Heatless Regeneration Compressed Air Treatment System

Large flow compressed air treatment systems providing clean, dry air (CDA) for general industrial, automotive, electronics and semiconductor manufacturing.

Technical Specifications

  • Division: Gas Separation and Filtration Division EMEA
  • Brand: Parker
  • Technology: Filtration
  • Application: Compressed Air Treatment - Clean Dry Air (CDA)
  • Product Type: Compressed Air Dryer with Filtration
  • Product Style: Heatless Regeneration (HL) and Vacuum Assisted Heatless Regeneration (LE)
  • Product Series: CDAS - Clean Dry Air System - Large Flow (Models CDAS HL/LE 100-170)
  • Industry: • General Industrial Manufacturing
    • Automotive
    • Electronics & Semiconductor Manufacturing
  • Flow Rate: Various (view part number for details)
  • Pressure Dew Point: Standard -40°C (-40°F) or -20°C (-4°F)
    , Alternative -70°C (-100°F)
  • ISO Grade: ISO 8573-1:2010 Class 2:2:2 / ISO 8573-1:2010 Class 2:3:2 or ISO 8573-1:2010 Class 2:1:2
  • Operating Pressure: 5 to 13 barg, 73 to 190 psig
  • Operating Temperature: 5 to 50 °C, 41 to 122 °F
  • Ambient Temperature: 55.0 °C Maximum, 131.0 °F Maximum
  • Power Supply Voltage: Various (view Part Number for details)
  • Port Size: Various (view Part Number for details)
  • Connection Type: BSPP or NPT (View Part Number For Details)
  • Ingress Protection Rating: IP44
  • Specifications Met: PED 2014/68/EU
  • Noise Level: < 75 dBA
  • Height: Various (view Part Number for details)
  • Width: Various (view Part Number for details)
  • Depth: Various (view Part Number for details)
  • Weight: View Part Number For Details
Safety Warning

Full Product Description

Parker CDAS Clean Dry Air Systems deliver clean, dry compressed air in accordance with all editions of ISO 8573-1, the international standard for compressed air quality. They are energy efficient and can provide pressure dewpoints of ≤-70°C, ≤-40°C or ≤-20°C at flow rates between 408 m³/hr and 2040 m³/hr @ 7 barg, 35°C for a single bank, higher flows available with multi-banking.

Using clean, dry compressed air improves productivity whilst reducing maintenance costs and downtime. Many products claim to provide this, however CDAS Clean Dry Air Systems provide high levels of compressed air purity with 3rd party validated performance in accordance with international standards.

Product Features
• Supplied with 4 Stages of purification, treating 7 of the 10 main compressed air contaminants (9 with optional liquid separator)
• Constant outlet dewpoint in accordance with ISO 8573-1 classes 1, 2 or 3 for water vapour
• Clean, dry purge air used for regeneration
• Dryer tested in accordance with ISO 7183
• Dewpoint performance 3rd party validated by LRQA
• HL models utilise standard Heatless PSA methodology for desiccant regeneration
• LE models utilise Low Energy vacuum assisted heatless methodology for desiccant regeneration (on average 64% more energy efficient than HL equivalent)
• No heat required for regeneration
• Inlet pressure, temperature and outlet dewpoint measurement as standard
• Colour HMI touch screen for dryer monitoring and outlet dewpoint display
• Two energy saving systems included as standard: Purge Economy (compressor synchronization) and DDS-EST dewpoint dependant switching
• Web Server for dryer monitoring via local area network (LAN)
• MODBUS TCP/IP & MODBUS RTU

To ensure quoted performance, a compressed air dryer must be sized using the correction factors found in the product information sheet.

To discuss your specific requirements please contact Parker or an authorised Parker distributor.

Related Documents

×
Products Flow Rate Pressure Dew Point ISO Grade Connection Type Port Size Pump Type
CDASHL100-40G13BC 408 m³/h/hr @ 7 barg, 35°C (240 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 BSPP 2" N/A
CDASHL100-70G13BC 286 m³/h/hr @ 7 barg, 35°C (168 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 BSPP 2" N/A
CDASHL110-40G13BC 612 m³/h/hr @ 7 barg, 35°C (360 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 BSPP 2" N/A
CDASHL110-70G13BC 428 m³/h/hr @ 7 barg, 35°C (252 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 BSPP 2" N/A
CDASHL120-40G13BC 765 m³/h/hr @ 7 barg, 35°C (450 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 BSPP 2½" N/A
CDASHL120-70G13BC 536 m³/h/hr @ 7 barg, 35°C (315 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 BSPP 2½" N/A
CDASHL130-40G13BC 1020 m³/h/hr @ 7 barg, 35°C (600 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 BSPP 2½" N/A
CDASHL130-70G13BC 714 m³/h/hr @ 7 barg, 35°C (420 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 BSPP 2½" N/A
CDASHL140-40G13BC 1275 m³/h/hr @ 7 barg, 35°C (750 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 BSPP 2½" N/A
CDASHL140-70G13BC 893 m³/h/hr @ 7 barg, 35°C (525 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 BSPP 2½" N/A
CDASHL150-40G13BC 1530 m³/h/hr @ 7 barg, 35°C (900 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 BSPP 2½" N/A
CDASHL150-70G13BC 1071 m³/h/hr @ 7 barg, 35°C (630 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 BSPP 2½" N/A
CDASHL160-40G13BC 1785 m³/h/hr @ 7 barg, 35°C (1050 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 BSPP 3" N/A
CDASHL160-70G13BC 1250 m³/h/hr @ 7 barg, 35°C (735 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 BSPP 3" N/A
CDASHL170-40G13BC 2040 m³/h/hr @ 7 barg, 35°C (1200 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 BSPP 3" N/A
CDASHL170-70G13BC 1428 m³/h/hr @ 7 barg, 35°C (840 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 BSPP 3" N/A
CDASLE100-40G13BC 408 m³/h/hr @ 7 barg, 35°C (240 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 BSPP 2" Vacuum: HLVAP-OL-02-100 (Order Separately)
CDASLE100-70G13BC 286 m³/h/hr @ 7 barg, 35°C (168 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 BSPP 2" Vacuum: HLVAP-OL-02-100 (Order Separately)
CDASLE110-40G13BC 612 m³/h/hr @ 7 barg, 35°C (360 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 BSPP 2" Vacuum: HLVAP-OL-02-110 (Order Separately)
CDASLE110-70G13BC 428 m³/h/hr @ 7 barg, 35°C (252 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 BSPP 2" Vacuum: HLVAP-OL-02-110 (Order Separately)
CDASLE120-40G13BC 765 m³/h/hr @ 7 barg, 35°C (450 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 BSPP 2½" Vacuum: HLVAP-OL-02-120 (Order Separately)
CDASLE120-70G13BC 536 m³/h/hr @ 7 barg, 35°C (315 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 BSPP 2½" Vacuum: HLVAP-OL-02-120 (Order Separately)
CDASLE130-40G13BC 1020 m³/h/hr @ 7 barg, 35°C (600 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 BSPP 2½" Vacuum: HLVAP-OL-02-130 (Order Separately)
CDASLE130-70G13BC 714 m³/h/hr @ 7 barg, 35°C (420 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 BSPP 2½" Vacuum: HLVAP-OL-02-130 (Order Separately)
CDASLE140-40G13BC 1275 m³/h/hr @ 7 barg, 35°C (750 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 BSPP 2½" Vacuum: HLVAP-OL-02-140 (Order Separately)
CDASLE140-70G13BC 893 m³/h/hr @ 7 barg, 35°C (525 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 BSPP 2½" Vacuum: HLVAP-OL-02-140 (Order Separately)
CDASLE150-40G13BC 1530 m³/h/hr @ 7 barg, 35°C (900 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 BSPP 2½" Vacuum: HLVAP-OL-02-150 (Order Separately)
CDASLE150-70G13BC 1071 m³/h/hr @ 7 barg, 35°C (630 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 BSPP 2½" Vacuum: HLVAP-OL-02-150 (Order Separately)
CDASLE160-40G13BC 1785 m³/h/hr @ 7 barg, 35°C (1050 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 BSPP 3" Vacuum: HLVAP-OL-02-160 (Order Separately)
CDASLE160-70G13BC 1250 m³/h/hr @ 7 barg, 35°C (735 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 BSPP 3" Vacuum: HLVAP-OL-02-160 (Order Separately)
CDASLE170-40G13BC 2040 m³/h/hr @ 7 barg, 35°C (1200 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 BSPP 3" Vacuum: HLVAP-OL-02-170 (Order Separately)
CDASLE170-70G13BC 1428 m³/h/hr @ 7 barg, 35°C (840 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 BSPP 3" Vacuum: HLVAP-OL-02-170 (Order Separately)
CDASHL100-40N13BC 408 m³/hr @ 7 barg, 35°C (240 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 NPT 2" N/A
CDASHL100-70N13BC 286 m³/hr @ 7 barg, 35°C (168 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 NPT 2" N/A
CDASHL110-40N13BC 612 m³/hr @ 7 barg, 35°C (360 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 NPT 2" N/A
CDASHL110-70N13BC 428 m³/hr @ 7 barg, 35°C (252 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 NPT 2" N/A
CDASHL120-40N13BC 765 m³/hr @ 7 barg, 35°C (450 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 NPT 2½" N/A
CDASHL120-70N13BC 536 m³/hr @ 7 barg, 35°C (315 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 NPT 2½" N/A
CDASHL130-40N13BC 1020 m³/hr @ 7 barg, 35°C (600 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 NPT 2½" N/A
CDASHL130-70N13BC 714 m³/hr @ 7 barg, 35°C (420 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 NPT 2½" N/A
CDASHL140-40N13BC 1275 m³/hr @ 7 barg, 35°C (750 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 NPT 2½" N/A
CDASHL140-70N13BC 893 m³/hr @ 7 barg, 35°C (525 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 NPT 2½" N/A
CDASHL150-40N13BC 1530 m³/hr @ 7 barg, 35°C (900 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 NPT 2½" N/A
CDASHL150-70N13BC 1071 m³/hr @ 7 barg, 35°C (630 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 NPT 2½" N/A
CDASHL160-40N13BC 1785 m³/hr @ 7 barg, 35°C (1050 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 NPT 3" N/A
CDASHL160-70N13BC 1250 m³/hr @ 7 barg, 35°C (735 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 NPT 3" N/A
CDASHL170-40N13BC 2040 m³/hr @ 7 barg, 35°C (1200 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 NPT 3" N/A
CDASHL170-70N13BC 1428 m³/hr @ 7 barg, 35°C (840 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 NPT 3" N/A
CDASLE100-40N13BC 408 m³/hr @ 7 barg, 35°C (240 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 NPT 2" Vacuum: HLVAP-OL-02-100 (Order Separately)
CDASLE100-70N13BC 286 m³/hr @ 7 barg, 35°C (168 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 NPT 2" Vacuum: HLVAP-OL-02-110 (Order Separately)
CDASLE110-40N13BC 612 m³/hr @ 7 barg, 35°C (360 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 NPT 2" Vacuum: HLVAP-OL-02-120 (Order Separately)
CDASLE110-70N13BC 428 m³/hr @ 7 barg, 35°C (252 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 NPT 2" Vacuum: HLVAP-OL-02-130 (Order Separately)
CDASLE120-40N13BC 765 m³/hr @ 7 barg, 35°C (450 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 NPT 2½" Vacuum: HLVAP-OL-02-140 (Order Separately)
CDASLE120-70N13BC 536 m³/hr @ 7 barg, 35°C (315 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 NPT 2½" Vacuum: HLVAP-OL-02-150 (Order Separately)
CDASLE130-40N13BC 1020 m³/hr @ 7 barg, 35°C (600 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 NPT 2½" Vacuum: HLVAP-OL-02-160 (Order Separately)
CDASLE130-70N13BC 714 m³/hr @ 7 barg, 35°C (420 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 NPT 2½" Vacuum: HLVAP-OL-02-170 (Order Separately)
CDASLE140-40N13BC 1275 m³/hr @ 7 barg, 35°C (750 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 NPT 2½" Vacuum: HLVAP-OL-02-100 (Order Separately)
CDASLE140-70N13BC 893 m³/hr @ 7 barg, 35°C (525 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 NPT 2½" Vacuum: HLVAP-OL-02-110 (Order Separately)
CDASLE150-40N13BC 1530 m³/hr @ 7 barg, 35°C (900 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 NPT 2½" Vacuum: HLVAP-OL-02-120 (Order Separately)
CDASLE150-70N13BC 1071 m³/hr @ 7 barg, 35°C (630 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 NPT 2½" Vacuum: HLVAP-OL-02-130 (Order Separately)
CDASLE160-40N13BC 1785 m³/hr @ 7 barg, 35°C (1050 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 NPT 3" Vacuum: HLVAP-OL-02-140 (Order Separately)
CDASLE160-70N13BC 1250 m³/hr @ 7 barg, 35°C (735 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 NPT 3" Vacuum: HLVAP-OL-02-150 (Order Separately)
CDASLE170-40N13BC 2040 m³/hr @ 7 barg, 35°C (1200 cfm @ 102 psig, 95°F) -40°C (-40°F) or -20°C (-4°F) Option Class 2.2.2 or Class 2.3.2 NPT 3" Vacuum: HLVAP-OL-02-160 (Order Separately)
CDASLE170-70N13BC 1428 m³/hr @ 7 barg, 35°C (840 cfm @ 102 psig, 95°F) -70°C (-100°F) Class 2.1.2 NPT 3" Vacuum: HLVAP-OL-02-170 (Order Separately)