TOC Turbine Oil Coalescing System | #TOC30F-4


LOADING IMAGES
TOC30F-4

TOC Turbine Oil Coalescing System | #TOC30F-4

Parker Velcon TOC Turbine Oil Coalescing System for Removal of Water and Dirt from Lube Oil


Especificaciones técnicas

  • Marca: Velcon
  • Aplicación: Industrial
  • Frecuencia (Hz): 60
  • Fase de energía: 3
  • Tensión de entrada (V CA): 460
  • Opciones del motor: Low RPM
  • Caudal (gpm): 30
  • Altura: 60 inch
  • Anchura: 66 inch
  • Profundidad: 42 inch
  • Peso: 1750 lb
  • Aplicación: Industrial
  • Tipo de productos: Turbine Lube Oil Filter Systems
Safety Warning

Información del artículo

Turbine Oil Coalescing Systems
TOC Series

Improved Oil Processing with Low Maintenance System

Velcon Filters has over 50 years experience designing and manufacturing coalescing filtration equipment. The TOC Series units combine the latest coalescing technology with the finest available microglass filter media to restore turbine lube oil to an exceptionally clean and dry condition. The units can be used to upgrade or replace older, low efficiency reservoir filtration systems.

PERFORMANCE
• Restore oil to an ISO cleanliness of 14/11 or better
• Continuously remove free water down to 150 ppm or less
• Prevent system sludging and premature oil degradation
• Field test data available on request

SIMPLICITY
• Compact, one button operation for round-the-clock service
• No adjustment needed for varying contaminant inlet levels
• Prefilter extends life of specialized coalescing elements
• One-page operation summary, components labeled to match gauges

RELIABILITY
• Rugged ASME design vessels assure safe, leak-free service
• Heavy-duty Viking pump is factory coupled for years of maintenance free service – there are no other moving parts
• Magnetic starter with overload protection
• Complete system is factory hydro-tested and operated before shipping

SPECIFICATIONS

Electrical
• 1750 RPM TEFC motor
• NEMA 4 motor control enclosure with “motor running” light
• Magnetic motor starter with manual reset and over - load protection
• Liquid-tight flexible conduit complete from panel to motor in accordance with IEEE standards. User to supply power cord and plug.
• Adjustable high pressure shut-off switch
• All electrical components UL listed/CSA approved Mechanical
• Positive displacement gear pump with factory set internal bypass and external adjustable flow bypass, maximum output pressure 100 psi
• 304 stainless steel tubing with JIC plated steel fittings. External hoses not supplied.
• 1/4 turn ball valves installed on drains, inlet and outlet, and at each stage for isolation. All flow valves are full port design.
• Inlet/outlet connections with cam and groove fitting quick-disconnect male coupling with dust caps
• Pressure vessels built in accordance with ASME Sec. VIII for maximum operating pressure of 150 psi. Carbon steel construction.
• Self-venting automatic air eliminators on each stage
• 60 mesh in-line strainer, no tools needed for inspectionGeneral

General
• Effluent sampling port for quick check on system performance
• Static and differential pressure gauges, with stainless steel tubing, for monitoring each stage
• Oven-cured, high corrosion resistant, powder coat white paint (polyester polyurethane)
• All controls and connections accessible from one side of system
• Filters tested to ANSI B93.31 (ISO 4572), multi-pass method for evaluating filtration performance of fine hydraulic fluid power filter elements. Beta ratio data available upon request.

Leer más Mostrar menos

Diseños en CAD + Archivos

No hay archivo CAD disponible

OK

x


Encontrar un distribuidor

Puntos de venta

Contacto local

Parker AFD - Aerospace Business Unit

Aerospace Filtration Division

8439 Triad Drive

Greensboro, NC 27409

USA

Teléfono

336-668-4444

Fax

336-668-4452

Consiga su cuenta de Parker hoy mismo!

Cree una cuenta para gestionar todo lo que haga con Parker, desde sus preferencias de compra hasta su acceso a la aplicación.

687PDC
731421