PSA Nitrogen Generators - MonoBed | #MB-5-PPM


LOADING IMAGES
MB-5-PPM

PSA Nitrogen Generators - MonoBed | #MB-5-PPM

Produce up to 99.99% pure, compressed nitrogen at dewpoints to -58°F (-50°F) from nearly any compressed air supply


Especificaciones técnicas

  • Caudal: 112 to 165 SCFH
  • Pureza del gas: 99.95 to 99.99 %
  • Marca: Balston, Parker
  • División: Industrial Gas Filtration and Generation Division
  • Industria: Industrial Manufacturing Equipment, Food & Beverage, Aviation, Oil & Gas
  • Aplicación: Industrial, Heat Treatment, Laser Cutting
  • Tecnología: Filtration
  • Tipo de productos: Nitrogen Gas Generator
  • Caudal: 112 to 165
  • Tipo de gas generado: Nitrogen
  • Pureza del gas: 99.95 to 99.99 %
  • Tamaño del puerto de entrada: 1/2 inch
  • Tamaño del puerto de salida: 1/2 inch
  • Tipo de puerto: NPT
  • Requisitos eléctricos: Yes
  • Voltaje de entrada: 120 VAC
  • Consumo de energía: 180 W
  • Corriente: 1.5 A
  • Temperatura ambiente: 40 to 95 °F
  • Rango de presión de entrada: 80 to 140 psig
  • Compresor incluido: No
  • Punto de rocío: -50 °C, -58 °F
  • Grado de protección de admisión: IP20, NEMA 1
  • Especificaciones de la calidad del aire de entrada: ISO 8573-1:2010 Class 2.4.2
  • Contenido en oxígeno: 100 to 500 ppm
  • Peso: 835 lb
  • Altura: 77 inch
  • Anchura: 29 inch
  • Profundidad: 27 inch
  • Nivel de ruido: < 85 dBA
  • Temperatura máxima de entrada de aire: 105
Safety Warning

Información del artículo

Monobed Nitrogen Generators produce up to 99.99% pure, compressed nitrogen at dewpoints to -58°F (-50°F) from nearly any compressed air supply. Balston PSA Nitrogen Generators are designed to continually transform standard compressed air into nitrogen at safe, regulated pressures without operator attention.

Features:
• Monobed design
• Complete package with prefitration,and receiving tank
• Safe and reliable
• Produce 95 - 99.99% pure nitrogen
• Dewpoints to -58°F (-50°C)
• Final stage sterile air filter is USDA/
• FSIS accepted for use in federally inspected meat and poultry plants. In full compliance with FDA and GFSI requirements
• PSA towers require no maintenance

Leer más Mostrar menos

Diseños en CAD + Archivos

No hay archivo CAD disponible

OK

x

Documentos relacionados

×


Encontrar un distribuidor

Puntos de venta

Contacto local

PURIFICATION DEHYDRATION

4087 WALDEN AVENUE

LANCASTER

NY

UNITED STATES

14086

Teléfono

8885879733

Fax

8778573800

Consiga su cuenta de Parker hoy mismo!

Cree una cuenta para gestionar todo lo que haga con Parker, desde sus preferencias de compra hasta su acceso a la aplicación.

687PDC
688031