Nitrogen Generators for Solvent Evaporation | #NitroVap-2LV


LOADING IMAGES
NitroVap Gas Generators Series

Nitrogen Generators for Solvent Evaporation | #NitroVap Gas Generators Series

NitroVap Gas Generators Series


Especificaciones técnicas

  • Caudal: 287 SLPM
  • Para tipo de fluido: Nitrogen
  • Aplicación: Analytical Laboratory
  • Marca: Balston, Parker
  • Rango de presión de salida máxima: 15 psig
  • Punto de rocío: -20 °F, -29 °C
  • Requisitos eléctricos: None
  • Tamaño del puerto de salida: 1/4 inch
  • Tipo de puerto: NPT
  • Tamaño del puerto de entrada: 1/4 inch
  • División: Industrial Gas Filtration and Generation Division
  • Industria: Healthcare & Life Sciences, Industrial & Chemical Processing, Oil & Gas
  • Tipo de productos: Nitrogen Gas Generator
  • Tecnología: Filtration
Safety Warning

Información del artículo

Parker NitroVap Generators can provide clean, ultra-dry nitrogen to sample evaporators. The NitroVap generators are complete systems with state-of the-art, highly reliable components engineered for easy installation, operation and long term performance. These systems offer high nitrogen output flows in a miniature cabinet. The user can activate the manual SLEEP economy mode to eliminate compressed air consumption when the sample concentrator is not in use.
NitroVap Generators eliminate the inconvenience and cost of LN2 dewar, and nitrogen cylinder gas supplies. Uncontrollable price increases, dewar ice, condensation, contract negotiations, long term commitments, and tank rentals are no longer a concern. These gas generators incorporate a unique membrane separation technology which allows for immediate nitrogen delivery to the sample concentrator. The system offers a "lock it and leave it" operation of the sample concentrator with no downtime and without “running out of gas” mid blow-down.

Features/Benefits
• Ideal for any combination of sample evaporators up to 100 nozzle positions
• Produces clean, dry to -20°F dewpoint evaporator grade nitrogen from any standard laboratory compressed air source
• Accelerates evaporation by decreasing the partial vapor pressure above the solvent liquid
• Eliminates inconvenient and dangerous LN2 boil-off dewars and nitrogen gas cylinders from the laboratory
• Recommended and used by many sample concentrator and sample evaporator manufacturers
• Payback period of typically less than one year
• Sleep economy mode
• Silent operation and minimal operator attention required

Leer más Mostrar menos

Diseños en CAD + Archivos

No hay archivo CAD disponible

OK

x

Documentos relacionados

×


Encontrar un distribuidor

Puntos de venta

Contacto local

PURIFICATION DEHYDRATION

4087 WALDEN AVENUE

LANCASTER

NY

UNITED STATES

14086

Teléfono

8885879733

Fax

8778573800

Consiga su cuenta de Parker hoy mismo!

Cree una cuenta para gestionar todo lo que haga con Parker, desde sus preferencias de compra hasta su acceso a la aplicación.

687PDC
688031