Especificaciones técnicas

  • Caudal: 12 GAL/MIN, 45 L/MIN
  • Rango de presión de entrada máxima: 6000 PSI, 420 BAR
  • Tipo de aguja: Fine
  • Mecanismo de ajuste: Tamper Resistant
  • Material de la junta: Nitrile
  • División: Mobile Hydraulic Systems Division Europe
  • Caudal: 12 gal/min, 45 L/min
  • Rango de presión de entrada máxima: 6000 psi, 420 bar
  • Tipo de aguja: Fine
  • Mecanismo de ajuste: Tamper Resistant
  • Material de la junta: Nitrile
  • Índice de caudal máximo: 12 gal/min, 45 L/min
  • Presión de trabajo máxima: 6000 psi, 420 bar
  • Tipo de accionamiento: Manual
  • Configuración: Needle
  • Función: 2-Way
  • Tipo de operación: Manually operated
  • Tasa de fuga: 5 @ 1450 PSI (100 BAR) drops/min
  • Tamaño de la cavidad: C08-2
  • Par de instalación: 30 lb-ft, 40 Nm
  • Para tipo de fluido: Mineral-based or synthetic hydraulic fluids
  • Viscosidad cinemática máxima: 45-2000 SSU (6 to 420 cSt)
  • Clasificación de eficiencia del filtro: ISO 4406 18/16/13, SAE Class 4
  • Material de la válvula: All parts steel. All operating parts hardened steel
  • Temperatura de funcionamiento: -30 to +250 °F, -34 to +121 °C
  • Temperatura máxima de funcionamiento: +250 °F, +121 °C
  • Temperatura mínima de funcionamiento: -30 °F, -34 °C
  • Peso: 0.24 lb, 0.11 kg
  • Material del cuerpo: N/A
  • Tamaño de la conexión: N/A
  • Tipo de conexión: N/A
Safety Warning

Información del artículo

Needle valves offer economical solutions for applications that require basic adjustable control of hydraulic flow. The effective orifice size inside the valve is varied with screw or knob adjustments and the valve can be made tamper resistant with the addition of an optional cap. Shutoff can be achieved when the valve is adjusted completely closed. Once the adjustment is set, the valve acts as a fixed orifice. Like all fixed orifices, any changes in pressure will cause changes in flow. If constant flow is required regardless of system or load pressure, please consider Parker’s pressure compensated flow controls. Parker’s J02A2, NVH081, NVH101, and J06A2 cartridges are basic 2-port needle valves with fine adjustment options available. The orifice will meter in both directions, but flow from port 2 to 1 is preferred. If unrestricted reverse flow is required, an additional check valve will need to be used with these needle valve versions. Parker also offers J02B2, FV101, and FV102 needle valves with internal reverse free flow checks in order to reduce manifold size and component quantities. Typical applications and industries include Accumulator Bleed-off, Motor Speed Control, Cylinder Speed Control, Bleed-Off Flow, Power Units, Oil and Gas, Material Handling, Construction, Drills, Presses, Mixers, Agriculture, Balers, Combines, etc.

Leer más Mostrar menos

Diseños en CAD + Archivos

Número de pieza
J02A2TN IGS STP

OK

x

Documentos relacionados

×


Encontrar un distribuidor

Puntos de venta

Contacto local

HYDRAULIC CARTRIDGE SYSTEMS

595 SCHELTER ROAD

LINCOLNSHIRE

IL

UNITED STATES

60069

Teléfono

847 955 5000

Fax

847 383 8900

Consiga su cuenta de Parker hoy mismo!

Cree una cuenta para gestionar todo lo que haga con Parker, desde sus preferencias de compra hasta su acceso a la aplicación.

687PDC
327264