Zero Air Generators (Low Flow Up To 1 L/min) | Product Series

Filtrar por

    No hay ningún filtro seleccionado

Conexión eléctrica

Consiga su cuenta de Parker hoy mismo!

Cree una cuenta para gestionar todo lo que haga con Parker, desde sus preferencias de compra hasta su acceso a la aplicación.


LOADING IMAGES
Zero Air Generators (Low Flow Up To 1 L/min)

Zero Air Generators (Low Flow Up To 1 L/min)

Extremely reliable zero air generators providing air free of total hydrocarbons to <0.1 ppm at flow rates up to 1 L/min.

Especificaciones técnicas

  • Marca: Balston, Parker
  • División: Gas Separation and Filtration Division EMEA
  • Industria: Healthcare & Life Sciences, Industrial & Chemical Processing, Oil & Gas
  • Aplicación: Analytical Laboratory, GC Combustion Detector
  • Tecnología: Filtration
  • Tipo de productos: Zero Air Gas Generator
  • Caudal: 1 L/min
  • Tipo de gas generado: Zero Air (Hydrocarbon Free)
  • Pureza del gas: < 0.1 ppm (Organic Impurity)
  • Tamaño del puerto de salida: 1/4 inch
  • Tipo de puerto: Female NPT
  • Requisitos eléctricos: Yes
  • Voltaje de entrada: 230 VAC 50 Hz
  • Conexión eléctrica: EU Plug, UK Plug
  • Temperatura ambiente: 50 to 95 °F, 10 to 35 °C
  • Rango de presión de entrada: 8 barg Max., 116 psig Max.
  • Kit de mantenimiento preventivo: 12 Months: MK7583
  • Compresor incluido: No
  • Peso: 4.4 lb, 2 kg
  • Altura: 9.85 inch, 250 mm
  • Anchura: 300 mm, 11.8 inch
  • Profundidad: 80 mm, 3.15 inch
Safety Warning

Descripción completa del producto

The Parker Balston Zero Air Generator can produce up to 1 L/min of high purity zero grade air. Compressed air is pre-filtered down to 0.01 micron and then purified using a state of the art combined heated catalyst module.

There are no moving parts and no noise, making the generator extremely reliable and ideal to install in the laboratory. Simple and quick to install, the Zero Air Generator requires minimal maintenance just once a year.

The resultant air is free of total hydrocarbons (THC) to < 0.1ppm making it ideal for all FID applications. The low levels guarantee a low signal to noise ratio, ensuring a flat constant base line with no peaks or fluctuations.

Features / Benefits

• Ultra high purity air for GC / FID applications

• Payback period typically less than one year

• Silent operation and minimal operator attention required

• Eliminate inconvenient and potentially dangerous air cylinders from the laboratory

• Models available to service up to 75 FIDs

• Increases the accuracy and repeatability of analysis

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.

Documentos relacionados

×
Productos Conexión eléctrica
75-83EU EU Plug
75-83UK UK Plug

687PDC
A22066