Blower Purge Heat Reactivated Desiccant Air Dryer -TWB Series | Product Series

Filtrar por

    No hay ningún filtro seleccionado

Índice de caudal máximo (cfm)

Requisitos eléctricos

Punto de rocío a presión (F)

Consiga su cuenta de Parker hoy mismo!

Cree una cuenta para gestionar todo lo que haga con Parker, desde sus preferencias de compra hasta su acceso a la aplicación.


LOADING IMAGES
Blower Purge Heat Reactivated Desiccant Air Dryer -TWB Series

Blower Purge Heat Reactivated Desiccant Air Dryer -TWB Series

Parker Airtek TWB Series Externally Heated Blower Purge Desiccant Air Dryers use heat and the adsorption method to remove moisture from compressed air. Pressure dewpoint of -40°F (-40°C) and flowrate of 200 – 7500 scfm depending on model.

Especificaciones técnicas

  • Aplicación: Industrial
  • Marca: Airtek
  • Accesorios opcionales: Pre and After Filtration
  • Tipo de conexión: 1” NPT, 1 1/2” NPT, 1 1/2" NPT, 2" NPT, 3" Flg, 4" Flg, 6" Flg, 8" Flg
  • Índice de caudal máximo: 170 to 15291 m3/hour
  • Rango de presión de entrada máxima: 100 psi
  • Presión de trabajo máxima: 150, 135
  • Presión mínima de trabajo: 80 psi
  • Temperatura máxima de funcionamiento: 120 °F
  • Temperatura mínima de funcionamiento: 50 °F
  • Temperatura ambiente máxima: 120 °F
  • Temperatura ambiente mínima: 50 °F, 40 °F
  • Índice de presión de purga: 0
  • Peso: 1050 to 24890 lb
  • Anchura: 49 to 146 inch, Consult Factory inch
  • Profundidad: 27 to 92 inch
  • Altura: 83 to 114 inch
  • Prefiltro compatible: JC0110-C, JC0250-C, JC0350-C, JC0450-C, JC0625-C, JC0800-C, JC1000-C, JLA1603-C, JLA2100-C, JLA3200-C, JLA3206-C, JLA4500-C, JLA5000-C, JLA7206-C, Consult Factory
  • Filtro posterior compatible: JC0150-FH, JC0250-FH, JC0350-FH, JC0450-FH, JC0625-FH, JC0800-FH, JC1000-FH, JLA1800-FH, JLA2600-FH, JLA3506-FH, JLA5306-FH, JLA6000-FH, Consult Factory
  • Elemento de prefiltro compatible: JE-CC0110, JE-CC0350, JE-CC0450, JE-CC0625, JE-CC0800, JAE4-C, (2) JAE3-C, (3) JAE3-C, (4) JAE3-C, (6) JAE3-C, (7) JAE3-C, (9) JAE3-C, Consult Factory
  • Elemento de filtro posterior compatible: JE-FC0150-HT, JE-FC0350-HT, JE-FC0450-HT, JE-FC0625-HT, JE-FC0800-HT, JAE4-FH, (2) JAE3-FH, (3) JAE3-FH, (4) JAE3-FH, (5) JAE3-FH, Consult Factory
  • Tipo de drenaje de agua condensada instalado: Times Solenoid Drain, Demand Solenoid Drain
  • Tipo de productos: Desiccant, Blower Purge, Blower Purge
Safety Warning

Descripción completa del producto

Compressed air is polluted with dirt particles, water, oil, oil vapor, and condensate.  These contaminants result in high maintenance costs, premature wear, spoiled products and the failure of control systems.
Parker Airtek TWB Series Blower Purge Desiccant Air Dryers will effectively remove these contaminants.  The traditional adsorption principle used in this design is simple, robust and flexible using compressed air for regeneration therefore eliminating any need for an outside energy supply.
Continuous drying is accomplished by the operation of two desiccant towers.  

Compressed air is dried through one tower while the other desiccant tower is being regenerated.  The regeneration heating cycle of the desiccant is accomplished using a hot air flow delivered by an atmospheric blower and external electric heater (other means of heating are optional).  The regeneration cooling cycle is performed using a small flow of dry compressed air taken from the blower purge dryer outlet to ensure dewpoint performance. High levels of reliability are achieved by the use of proven engineering technology and components.

Features/Benefits
• Flow rate starting at 200 scfm (340 m3/hr)
• Delivered air quality is in accordance with ISO 8573.1: 2001, the international standard for compressed air quality.
• Pressure dewpoints of -100°F (-70°C) & -40°F (-40°C) (ISO 8573.1: 2001 Classes 1 & 2) are available.
• Parker Airtek pre- and after compressed air filters - Standard
• PowerLoc Energy Management System* - Standard
• Low-wattage high incoloy sheathed heater for efficient regeneration
• High-efficiency, quiet running regenerative (up to 3000 scfm) or centrifugal blowers (4000 scfm and larger)
• Parker non-lubricated full-flow angle seat valves, which carry a FIVE YEAR VALVE WARRANTY, are standard on dryers up to 800 scfm.
• High performance, actuated butterfly switching valves, which carry a FIVE YEAR VALVE WARRANTY, are standard on dryers 1000 scfm and larger.
• Insulated tower, heater and purge lines increase dryer performance and efficiency by reducing radiant heat loss plus keeps the unit with the safety parameters set forth by OSHA.
• Easy to use Control Center affords superior dryer control along with digital telemetry for remote analysis of performance.
• Custom filter packaging*
• 7” HMI, Allen-Bradley® PLC
• Flash drive port for transferring data log
• Serial communications port (optional)
• Emergency stop and standby mode
• Automatic data logging 24/7, 365 days of all operational information
*Optional equipment

Documentos relacionados

×
Productos Índice de caudal máximo (cfm) Requisitos eléctricos Punto de rocío a presión (F)
TWB201BY41NNN 200 460V/3Ph/60Hz -40
TWB301BY41NNN 300 460V/3Ph/60Hz -40
TWB401BY41NNN 400 460V/3Ph/60Hz -40
TWB501BY41NNN 500 460V/3Ph/60Hz -40
TWB601BY41NNN 600 460V/3Ph/60Hz -40
TWB801BY41NNN 800 460V/3Ph/60Hz -40
TWB1001FY41NNN 1000 460V/3Ph/60Hz -40
TWB1201FY41NNN 1200 460V/3Ph/60Hz -40
TWB1501FY41NNN 1500 460V/3Ph/60Hz -40
TWB2001FY41NNN 2000 460V/3Ph/60Hz -40
TWB2601FY41NNN 2600 460V/3Ph/60Hz -40
TWB3001FY41NNN 3000 460V/3Ph/60Hz -40
TWB4001FY41NNN 4000 460V/3Ph/60Hz -40
TWB5001FY41NNN 5000 460V/3Ph/60Hz -40
TWB6001FY41NNN 6000 460V/3Ph/60Hz -40
TWB7501FY41NNN 7500 460V/3Ph/60Hz -40
TWB9001FY41NNN 9000 460V/3Ph/60Hz -40

687PDC
688031