Parker Conflow’s Code 5050 is an electronic flow meter that provides effective measurement of output flow rate, pressure and temperature. The unit incorporates an on-board LCD display showing rate, pressure and temperature, for ease of reading. Code 5050 is accurate to 1.5% of FSD (1%, 0-80°C).
It works via a linear electrical signal which corresponds to the volume rate of flow of fluid in the pipeline or system in mining and quarrying applications. It is also compatible with a wide range of instruments, data loggers, display devices and outstations to provide remote display of fluid flow, fluid temperature and totalization of flow over a time period.
Code 5050 is available in 1/2", 3/4",1" & 1 1/4” sizes and to a maximum working pressure of 400 Bar. Flow output versions include 4 – 20mA or 0.4 – 2 VDC.
Markets:
• Quarrying
• Mining
• Power stations
• Steelworks
Features/Benefits:
• Provides pressure, flow and temperature levels, including totalisation, since last reading.
• Robust in its detection.
• Easy to read display.
• Can connect to outside datalogger for remote monitoring.
• Accuracy 1.5% of FSD (1%, 0-80°C).
• Cable Gland Entries.
• I.S. Approved - Cert. ATEX 05ATEX2294, IECEX SIR05.0061 AN2Ex 06.3032x
• Unit available with or without pressure transducer.
Applications:
• Monitoring water or oil flows to the various systems on coal cutting machines, AFC gearboxes and roof bolting machinery.
• Monitoring water lines for dust suppression, motor cooling, ITP systems and fire fighting.