30, 50, 75 GPM Insulating Oil Filters System

30, 50, 75 GPM Insulating Oil Filters System

Parker Velcon HCP30, HDP50 & HDP75 Insulating Oil Filters Skids Systems for Removal of Water and Dirt from Insulating Oil.

Especificaciones técnicas

  • Altura: 52 inch
  • Anchura: 39 inch, 42 inch
  • Profundidad: 36 inch, 39 inch
  • Peso: 370 lb, 615 lb, 650 lb
  • Aplicación: Electric Utility
  • Tipo de productos: Insulating Oil Filter Systems
Safety Warning

Descripción completa del producto

Insulating Oil Filters

HCP30, HDP50 & HDP75

Heavy Duty Filter Pumps
Double Capacity, Twin Housings
Water and Dirt Removal From
Insulating Oil
HCP30: 30 GPM Two Stage Series-Flow Model
HDP50 & HDP75: 50 & 75 GPM Dual One-Stage Parallel-Flow Models

FEATURES
• High pumping rates
• Twin two-cartridge housings
• Quick cartridge change
• Minimum oil spill during operation
• Rugged welded steel construction
• Easy trailer mounting

DESCRIPTION

High performance HCP and HDP Series Filter Pumps provide fast, cost effective insulating oil filtration in the field.

HCP30 Series-Flow Filter-Pumps were developed for use with insulating oil having high levels of carbon contamination
as a primary problem and water contamination as a secondary problem.

The HCP configuration employs two different types of filter cartridges in series. The first housing, which holds two cost effective particulate cartridges, is utilized as a prefilter. The second housing holds two Aquacon® superabsorbent cartridges. Since the Aquacon Cartridges are utilized primarily for water removal, they seldom need to be replaced. This reduces operation costs.

HDP50 and HDP75 Parallel-Flow Models feature high flow rates. Oil is pumped through both two-cartridge housings at the same time, in parallel, for maximum flow.

Standard features for all models are listed on the reverse side of this data sheet. Safety features include a Pump
Pressure Relief Valve to prevent over-pressuring of the system. Also included is a built-in Adjustable Pressure Switch which senses the pressure ahead of the filters. It will shut the system down if a sudden surge of water should plug the Aquacon Cartridges. In the HCP30, this sensor is positioned ahead of the second stage.

A number of useful options are offered. The Delta P Gauge, for example, is a direct reading differential pressure gauge which eliminates any uncertainty about when to change cartridges. It is highly recommended.

The manual Flow Control Bypass is used to reduce system flow rate and is useful when topping off a tank. It is also strongly recommended when working with oil at temperatures of 40°F and colder because resulting higher viscosity can cause motor overload.

The Low RPM Motor option is a special 1140 RPM motor. (Standard RPM is 1740.) It is used in combination with a larger pump to achieve the desired flow rate with long runs of standard suction hose or hose of smaller diameter than recommended. Use of this motor will reduce or eliminate very high noise levels which can be generated by pump cavitation at the higher RPM.
Additional options are detailed on the reverse side of this sheet.

APPLICATIONS
• Transformers
• Tap Changer
• Switch Gear
• Circuit Breakers

SPECIFICATIONS
Standard Features, all HCP and HDP Models
• Totally Enclosed Fan-Cooled (TEFC) Motor
• Integral Pump Pressure Relief Valve – prevents system over-pressure
• 100 psi system design pressure
• All controls and connections accessible from one side
• Static Pressure Gauge (two on HCP30)
• Adjustable Pressure Shut-down Switch
• NEMA 12 Motor Control Enclosure
• Motor Starter with Manual Reset
• “Motor Running” Indicator Light
• 1/2” Sampling Port – for quick check on filter performance
• Fast Acting Ball Valves on drains and main lines
• Full port inlet & outlet isolation valves
• Quick-Disconnect Male Coupling with dust caps installed on inlet and outlets
• Manual Filter Bypass – transfer oil without filtering
• Special Inlet Basket Strainer – for quick inspections and cleaning without tools
• Carbon steel construction
• Wiring complete to motor control – user to install power cord and plug

HCP30:
Flow Rate (GPM): 30
Flow Arrangement: Series
Inlet/Outlet (in.): 1-1/2
Motor Horsepower: 2
Amps. (Single Phase): 115V/23A, 230V/12A
Ht/Width/Depth(in.): 52/39/36
Weight (lbs): 370

HDP500:
Flow Rate (GPM): 50
Flow Arrangement: Parallel
Inlet/Outlet (in.): 2
Motor Horsepower: 3
Amps. (Single Phase): 115V/30A, 230V/15A
Ht/Width/Depth(in.): 52/42/39
Weight (lbs): 615

HCP30:
Flow Rate (GPM): 75
Flow Arrangement: Parallel
Inlet/Outlet (in.): 3
Motor Horsepower: 5
Amps. (Single Phase): 230V/23A
Ht/Width/Depth(in.): 52/42/39
Weight (lbs): 650

FILTER CARTRIDGE INFORMATION
FO-718PL Series large surface area pleated media “dirt” cartridges are recommended for use in the first (prefilter) stage of the HCP30 only.

Aquacon® AC Series cartridges are for use in both systems. In addition to their outer particulate filter layer (offered in 0.3, 1/2, and 1 micron ratings), they also have a unique inner filter media which holds one to two quarts of water. Absorbed water is chemically locked in and cannot be squeezed out. When the cartridges reach their water holding capacity, their accordion pleats swell shut.
This causes an increase in the differential pressure which signals the operator to change the cartridges. If operation is unattended, the pressure increase can activate the automatic pressure switch and cause the system to shut down
until saturated cartridges are replaced.

FILTER CARTRIDGE RECOMMENDATIONS
Use two per housing)
HCP30: 1st Stage: FO-718PL1/2; 2nd Stage: AC-71801
HDP50 and HDP75: Either AC-7181/2 (Hi-Carbon) or
AC-71801 (Hi-Water)

ORDERING INFORMATION
Specify model number as shown below. Units are shipped without cartridges.

HCP30 HDP50 HDP75 POWER REQUIREMENT
HCP30-2 HDP50-2 HDP75-2 230 volts, 1 phase, 60 Hz
HCP30-3 HDP50-3 HDP75-3 230 volts, 3 phase, 60 Hz
HCP30-4 HDP50-4 HDP75-4 460 volts, 3 phase, 60 Hz
HCP30-5 HDP50-5 HDP75-5 575 volts, 3 phase, 60 Hz

Also available: 50 Hz power, explosion proof motor, variable speed motor, low RPM motor (contact factory)

RECOMMENDED SPARES
• Cartridges, 6 ea.
• G-1045 Buna-N Lid Gaskets, 2 ea.
Productos Aplicación Caudal (gpm) Tensión de entrada (V CA) Fase de energía Frecuencia (Hz) Opciones del motor Marca
HCP30-2 Electric Utility 30 230 1 60 0 Velcon
HCP30XP-2 Electric Utility 30 230 1 60 Explosion Proof Velcon
HCP30VS-2 Electric Utility 30 230 1 60 Variable Speed Velcon
HCP30F-2 Electric Utility 30 230 1 60 Low RPM Velcon
HCP30-3 Electric Utility 30 230 3 60 0 Velcon
HCP30XP-3 Electric Utility 30 230 3 60 Explosion Proof Velcon
HCP30VS-3 Electric Utility 30 230 3 60 Variale Speed Velcon
HCP30F-3 Electric Utility 30 230 3 60 Low RPM Velcon
HCP30-4 Electric Utility 30 460 3 60 0 Velcon
HCP30XP-4 Electric Utility 30 460 3 60 Explosion Proof Velcon
HCP30VS-4 Electric Utility 30 460 3 60 Variable Speed Velcon
HCP30F-4 Electric Utility 30 460 3 60 Low RPM Velcon
HCP30-5 Electric Utility 30 575 3 60 0 Velcon
HCP30XP-5 Electric Utility 30 575 3 60 Explorsion Proof Velcon
HCP30-7 Electric Utility 30 220 1 50 0 Velcon
HCP30XP-7 Electric Utility 30 220 1 50 Explosion Proof Velcon
HCP30-8 Electric Utility 30 220 3 50 0 Velcon
HCP30XP-8 Electric Utility 30 220 3 50 Explosion Proof Velcon
HCP30-9 Electric Utility 30 380 3 50 0 Velcon
HCP30XP-9 Electric Utility 30 380 3 50 Explosion Proof Velcon
HDP50-2 Electric Utility 50 230 1 60 0 Velcon
HDP50XP-2 Electric Utility 50 230 1 60 Explosion Proof Velcon
HDP50VS-2 Electric Utility 50 230 1 60 Variable Speed Velcon
HDP50-3 Electric Utility 50 230 3 60 0 Velcon
HDP50XP-3 Electric Utility 50 230 3 60 Explosion Proof Velcon
HDP50VS-3 Electric Utility 50 230 3 60 Variale Speed Velcon
HDP50-4 Electric Utility 50 460 3 60 0 Velcon
HDP50XP-4 Electric Utility 50 460 3 60 Explosion Proof Velcon
HDP50VS-4 Electric Utility 50 460 3 60 Variable Speed Velcon
HDP50-5 Electric Utility 50 575 3 60 0 Velcon
HDP50XP-5 Electric Utility 50 575 3 60 Explorsion Proof Velcon
HDP50-7 Electric Utility 50 220 1 50 0 Velcon
HDP50XP-7 Electric Utility 50 220 1 50 Explosion Proof Velcon
HDP50-8 Electric Utility 50 220 3 50 0 Velcon
HDP50XP-8 Electric Utility 50 220 3 50 Explosion Proof Velcon
HDP50-9 Electric Utility 50 380 3 50 0 Velcon
HDP50XP-9 Electric Utility 50 380 3 50 Explosion Proof Velcon
HDP75-2 Electric Utility 75 230 1 60 0 Velcon
HDP75XP-2 Electric Utility 75 230 1 60 Explosion Proof Velcon
HDP75VS-2 Electric Utility 75 230 1 60 Variable Speed Velcon
HDP75-3 Electric Utility 75 230 3 60 0 Velcon
HDP75XP-3 Electric Utility 75 230 3 60 Explosion Proof Velcon
HDP75VS-3 Electric Utility 75 230 3 60 Variale Speed Velcon
HDP75-4 Electric Utility 75 460 3 60 0 Velcon
HDP75XP-4 Electric Utility 75 460 3 60 Explosion Proof Velcon
HDP75VS-4 Electric Utility 75 460 3 60 Variable Speed Velcon
HDP75-5 Electric Utility 75 575 3 60 0 Velcon
HDP75XP-5 Electric Utility 75 575 3 60 Explorsion Proof Velcon
HDP75-7 Electric Utility 75 220 1 50 0 Velcon
HDP75XP-7 Electric Utility 75 220 1 50 Explosion Proof Velcon
HDP75-8 Electric Utility 75 220 3 50 0 Velcon
HDP75XP-8 Electric Utility 75 220 3 50 Explosion Proof Velcon
HDP75-9 Electric Utility 75 380 3 50 0 Velcon
HDP75XP-9 Electric Utility 75 380 3 50 Explosion Proof Velcon