ThermalStar Smart Cycling Refrigerated Air Dryer - TM Series

ThermalStar Smart Cycling Refrigerated Air Dryer - TM Series OBSOLETE

Note: This product is no longer available - please refer to the "Product Support" or "Recommended products" section of this page for details on any alternative products, or contact us for further assistance

Especificaciones técnicas

  • Marca: domnick hunter
  • Accesorios opcionales: Air Cooled Unit
  • Tipo de conexión: 3" Flg, 4" Flg, 6" Flg, 8" Flg, 10" Flg, 12" Flg
  • Índice de caudal máximo: 2123.76 to 25485.16 m3/hour
  • Rango de presión de entrada máxima: 100 psi
  • Presión de trabajo máxima: 200 psi, 150 psi
  • Presión mínima de trabajo: -
  • Temperatura máxima de funcionamiento: 131 °F
  • Temperatura mínima de funcionamiento: 41 °F
  • Temperatura ambiente máxima: 115 °F
  • Temperatura ambiente mínima: 41 °F
  • Tipo de refrigerante: R404A
  • Peso: 1850 to 14600 lb
  • Anchura: 74 to 150 inch
  • Profundidad: 41 to 100 inch
  • Altura: 65 to 120 inch
  • Prefiltro compatible: AO055JNFI, DH-AO250ODFI-1, DH-AO350PDFI-1, DH-AO400QDFI-1, DH-AO450RDFI-1, DH-AO500SDFI-1
  • Filtro posterior compatible: AA055JNFI, DH-AA250ODFI-1, DH-AA300ODFI-1, DH-AA350PDFI-1, DH-AA400QDFI-1, DH-AA450RDFI-1, DH-AA500SDFI-1
  • Elemento de prefiltro compatible: -
  • Elemento de filtro posterior compatible: -
  • Tipo de drenaje de agua condensada instalado: Level Actuated
  • Tipo de productos: Compressed Air – Refrigerated, ThermalStar Smart Dryers – Air Cooled

Descripción completa del producto

The importance of compressed air as a provider of energy for modern industrial processes is widely known. What is often overlooked, however, is the need to provide quality treatment for this air. In fact, the air entering the system contains condensate which, when cooled, will turn into liquid water, causing extensive damage not only to the compressed air network, but also to the finished product.

These costly contamination problems can be avoided by installing a TM1250 - TM3000 or TM4000 - TM15000 Cycling Refrigerated Air Dryer package complete with Parker domnick hunter filtration. The combination of our refrigerated dryers and high quality filtration provides air quality to ISO 8573.1 Class 1.4.1.

A refrigerated dryer is typically selected to achieve its design performance at the user's most extreme working conditions (ie. a warm summer day with the air compressor operating at maximum load). This maximum condition, however, is very rarely achieved in everyday conditions.

First, the air compressor load will vary significantly during a working day and will rarely be at full load, thereby significantly reducing the load on the dryer itself. Furthermore, average temperatures are well below the maximum inlet and ambient temperatures for which the system has been sized. Reduced temperatures at colder moments during the day and overall temperature reductions during the midseason and winter add a further reduction to the load on the dryer.

Features:

• Best in class dewpoint performance
• Tri Mode Operation allows dryer to operate in cycling, non-cycling or auto mode.
• Unlimited cycling due to unloaded “soft start”
• Multi-stage separation and filtration
• Level actuated drain
• Diagnostic readouts indicate need for service
• Drain light
• Alarm light
• Displays in English or Metric
• Serial Port with MODBUS
• Digital readout air in temperature
• Digital readout ambient or water in temperature
• High inlet temperature warning
• High ambient or water in temperature warning
• Optional eControl Center

Benefits:

• Lower dewpoint temperature achieved with ThermalStar Smart results in cleaner operation
• Longer lasting components
• Upstream malfunction that results in more severe inlet conditions can be readily handled without
• resulting in downstream problems
• Lower operating costs, with no sacrifice in performance
• Dryer runs only as needed
• Environmentally friendly refrigerant
• Tube and shell heat exchanger with grooved tube sheets provide greatest mechanical strength and lowest pressure drop
• Patented flood level control protects refrigeration circuit

Productos Índice de caudal máximo (cfm) Requisitos eléctricos Punto de rocío a presión (F)
DF-TM1250-A4 1250 460V/3Ph/60Hz 39
DF-TM1600-A4 1600 460V/3Ph/60Hz 39
DF-TM2050-A4 2050 460V/3Ph/60Hz 39
DF-TM2500-A4 2500 460V/3Ph/60Hz 39
DF-TM3000-A4 3000 460V/3Ph/60Hz 39
DF-TM4000-A4 4000 460V/3Ph/60Hz 39
DF-TM5000-A4 5000 460V/3Ph/60Hz 39
DF-TM6000-A4 6000 460V/3Ph/60Hz 39
DF-TM8000-A4 8000 460V/3Ph/60Hz 39
DF-TM10000-A4 10000 460V/3Ph/60Hz 39
DF-TM12500-A4 12500 460V/3Ph/60Hz 39
DF-TM15000-A4 15000 460V/3Ph/60Hz 39