Vapor Safety Relief Valves- H | #108646


LOADING IMAGES
108646
Click to View CAD Model

Vapor Safety Relief Valves- H | #108646

The H Series of Safety Relief Valves are designed to protect refrigeration systems from overpressure situations and feature a high flow capacity. The H Series are flanged for easy replacement and can be used in a single or dual relief combination.


Especificaciones técnicas

  • Ajuste de descarga de presión (bares): 15.9
  • Conexión de entrada: 1-1/4"FPT
  • Ajuste de descarga de presión (psig): 230
  • Conexión de salida: 2"FPT
  • Tamaño del orificio (pulg): 1.375
  • Tipo de válvula: H5
  • Tamaño del orificio (mm): 34.925
  • Capacidad de flujo (Libras Por minuto de aire): 364
  • Capacidad de flujo (SCFM aire): 4770
  • Número de modelo: -
  • Temperatura máxima de funcionamiento: 150 °C, 300 °F
  • Temperatura mínima de funcionamiento: -40° °C, -40° °F
  • Temperatura ambiente máxima: 94 °C, 200 °F
  • Temperatura ambiente mínima: -29° °C, -20° °F
  • Presión de trabajo máxima: 27.6 barg, 400 psig
  • Material del asiento: PTFE
  • Material de la válvula: External: Cast Iron, Internal: Stainless Steel
  • Tipo de válvula: H5
  • Caudal de aire: 4770 SCFM, 364 lb/min
  • Tamaño de la conexión de entrada: 1-1/4" FPT inch
  • Tamaño de la conexión de salida: 2"FPT
  • Tamaño del orificio: 34.925 mm, 1.375 inch
  • Ajuste de alivio de presión: 15.9 bar, 230 psig
  • Aplicación: Vapor Only

Información del artículo

The H Series high capacity safety relief valves are designed and constructed to meet the requirements of ASME Boiler and Pressure Vessel Code, ANSI/ASHRAE 15-2007 Code, and they bare the ASME Code Symbol (UV), indicating compliance with these codes. Employing proven principles of design, these safety relief valves are highly reliable. Precision machined moving parts of stainless steel, a PTFE disc and a cadmium-plated spring prevent sticking due to corrosion or cold welding to ensure valve opening at the set pressure long after installation. When it comes time for replacement, the two-bolt flanged bottom inlet affords for simple removal and replacement.

Two relief valves can be mounted on a Type M dual stop valve manifold to permit either valves to be shut off individually and removed for repair or inspection. Thus, one valve is always in service as required by most codes.
Markets:

• Industrial Refrigeration
• Commercial Refrigeration

Features and Benefits:

• Suitable for Use with Ammonia and Halocarbon refrigerants in non-corrosive environments
• High Capacity
• Excellent Repeatability
• All Stainless Steel Internal Parts
• Unaffected by Vibration
• Drain Plug Standard
• PTFE Seat

Application:

• Compressor Packages
• Accumulator Vessels
• Receiver Vessels
• Anywhere overpressure protection is required

Leer más Mostrar menos

Diseños en CAD + Archivos


Documentos relacionados

×

Cantidad
Solicitar un presupuesto

El artículo se ha añadido correctamente a la cesta de presupuesto IR A MIS COTIZACIONES

x

OK

x

Encontrar un distribuidor

Puntos de venta

Contacto local

Latin American Group Headquarters

Parker Hannifin Ind. e Com. Ltda.

Estrada Municipal Joel de Paula, 900

São José dos Campos

SP

Brasil

12247-015

Consiga su cuenta de Parker hoy mismo!

Cree una cuenta para gestionar todo lo que haga con Parker, desde sus preferencias de compra hasta su acceso a la aplicación.

687852
687475