Válvulas reguladoras de carga ventiladas por piloto estándar | #MHC-022-VCSH-00B


LOADING IMAGES
MHC-022-VCSH-00B MHC-022-VCSH-00B
Click to View CAD Model

Válvulas reguladoras de carga ventiladas por piloto estándar | #MHC-022-VCSH-00B

REGIONAL - Parker’s vented load control valves are designed to operate independent of downstream pressure to prevent runaway loads under all dynamic conditions, handling pressures up to 350 bar (5000 psi) and flows up to 113 lpm (30 gpm).


Especificaciones técnicas

  • Índice de caudal máximo: 25 GAL/MIN, 93.75 L/MIN
  • Ratio de presión del piloto: 5:1
  • Mecanismo de ajuste: Standard (adjustable)
  • Tipo de montaje: Threaded Cartridge Valve
  • Presión de sujeción: 3000 PSI, 210 BAR
  • Rango de control de presión: N/A
  • Tamaño del puerto: N/A
  • Material de la junta: Nitrile
  • División: Hydraulic Systems Division
  • Índice de caudal máximo: 25 gal/min, 93.75 L/min
  • Ratio de presión del piloto: 5:1
  • Mecanismo de ajuste: Standard (adjustable)
  • Tipo de montaje: Threaded Cartridge Valve
  • Presión de sujeción: 3000 psi, 210 bar
  • Rango de control de presión: N/A psi, N/A bar
  • Tamaño del puerto: N/A
  • Material de la junta: Nitrile
  • Caudal: 25 gal/min, 93.75 L/min
  • Presión de trabajo máxima: 5000 psi, 350 bar
  • Rango de presión de entrada máxima: 5000 psi, 350 bar
  • Sensibilidad de control de presión: N/A psi, N/A bar
  • Función: Counterbalance Valve
  • Tipo de accionamiento: Pilot Operated, Vented
  • Ubicación del piloto: External
  • Material del cuerpo: N/A
  • Dirección de flujo: Cylinder port 2, Valve port 3, Pilot port 1
  • Tasa de fuga: 5 @ 80% of setting drops/min
  • Tamaño de la cavidad: CDD-1036
  • Par de instalación: 102-108 Nm, 75-80 lb-ft
  • Para tipo de fluido: Mineral-based or synthetic hydraulic fluids
  • Clasificación de eficiencia del filtro: ISO 4406 18/16/13, SAE Class 4
  • Viscosidad cinemática máxima: 45-2000 SSU (6 to 420 cSt)
  • Material de la válvula: All parts steel. All operating parts hardened steel
  • Temperatura de funcionamiento: -30 to +250 °F, -34 to +121 °C
  • Temperatura máxima de funcionamiento: +250 °F, +121 °C
  • Temperatura mínima de funcionamiento: -30 °F, -34 °C
  • Peso: 0.88 lb, 0.38 kg

Información del artículo

Parker’s vented to atmosphere load holding/counterbalance valves are a combination of a relief, sequence, and flow control valve that can handle pressures up to 350 bar (5000 psi) and flows up to 113 lpm (30 gpm). These robust valves allow the operator to maintain control of the load by preventing it from overrunning the pump while also protecting against thermal expansion. The wide selection of pilot ratios enables the valve to open at pressures much lower than the spring pressure setting, allowing consistent control of the load throughout its lowering cycle. Because these valves spring chamber are vented to atmosphere, the valve will not be affected by changes in return pressure. Parker’s vented load holding valves are ideal in closed center circuits where there is need to control pressure using an auxiliary relief valve.



Markets:

• Aerial

• Construction Equipment

• Material Handling Equipment

• Miscellaneous Industrial

• Miscellaneous Mobile



Features/Benefits:

• Vented to atmosphere, no additional drain line required

• Hardened, precision ground parts for durability

• Poppet style construction with minimal leakage

• Tamperproof versions available

• Single cartridge valve with integral reverse flow check valve

• Available pilot ratios from 8:1 to 3:1

• All external parts zinc plated

 

Value Statement:

Parker MHC-Series counterbalance valves metering profile provides greater stability and smoother machine operation, resulting in less operator fatigue and improved productivity.



Applications:

• Load holding

• Position holding



Additional Technical Insight:

The load control valves are load assisted i.e the pilot pressure acts on the difference between the setting and the load at the pilot ratio.

The valve should always be set at a minimum of 30% higher than the maximum load induced pressure to ensure the valve closes correctly.

Sizing a counterbalance valve needs care in that the flow required is usually higher than system pump flow, as in the case with a cylinder application (retract flow could be twice the system flow) though oversizing the valve could cause instability.

Because of dynamic load variations in many applications, it may be necessary to use a lower pilot ratio or fit an orifice in the pilot line in order to gain stability.

Leer más Mostrar menos

Diseños en CAD + Archivos


Documentos relacionados

×

Cantidad
Solicitar un presupuesto

El artículo se ha añadido correctamente a la cesta de presupuesto IR A MIS COTIZACIONES

x

OK

x

Encontrar un distribuidor

Puntos de venta

Contacto local

Latin American Group Headquarters

Parker Hannifin Ind. e Com. Ltda.

Estrada Municipal Joel de Paula, 900

São José dos Campos

SP

Brasil

12247-015

Consiga su cuenta de Parker hoy mismo!

Cree una cuenta para gestionar todo lo que haga con Parker, desde sus preferencias de compra hasta su acceso a la aplicación.

687852
327264