Standard Pilot Assisted Load Control Valves | #E2A020ZN


LOADING IMAGES
E2A020ZN E2A020ZN
Click to View CAD Model

Standard Pilot Assisted Load Control Valves | #E2A020ZN

GLOBAL CORE - Parker’s piloted load control valves operate independent of downstream pressure to prevent runaway loads under dynamic conditions using a pilot signal, handling pressures up to 420 bar (6000 psi) and flows up to 350 lpm (90 gpm).


Especificaciones técnicas

  • Índice de caudal máximo: 3.7 GAL/MIN, 14 L/MIN
  • Ratio de presión del piloto: 8:1
  • Mecanismo de ajuste: Screw
  • Tipo de montaje: Threaded Cartridge Valve
  • Presión de sujeción: 3120 PSI, 215 BAR
  • Rango de control de presión: 725-6000 PSI, 50-420 BAR
  • Tamaño del puerto: N/A
  • Material de la junta: Nitrile
  • División: Mobile Hydraulic Systems Division Europe
  • Índice de caudal máximo: 3.7 gal/min, 14 L/min
  • Ratio de presión del piloto: 8:1, 8:01
  • Mecanismo de ajuste: Screw, Screw Adjustment
  • Tipo de montaje: Threaded Cartridge Valve
  • Presión de sujeción: 3120 psi, 215 bar
  • Rango de control de presión: 725-6000 psi, 50-420 bar
  • Tamaño del puerto: N/A
  • Material de la junta: Nitrile
  • Caudal: 3.7 gal/min, 14 L/min
  • Presión de trabajo máxima: 6000 psi, 420 bar
  • Tamaño de la rosca del puerto: N/A
  • Rango de presión de entrada máxima: 6000 psi, 420 bar
  • Sensibilidad de control de presión: 1640 per turn psi, 113 per turn bar
  • Temperatura de funcionamiento: -30° to +250° °F, -34° to +121° °C, -30 to +250 °F, -34 to +121 °C
  • Función: Counterbalance Valve
  • Tipo de accionamiento: Pilot Operated
  • Ubicación del piloto: External
  • Material del cuerpo: N/A
  • Viscosidad cinemática máxima: Mineral-based or synthetic with lubricating properties at viscosities of 45-2000 SSU (6 to 420 cSt) cSt, 45-2000 SSU (6 to 420 cSt)
  • Dirección de flujo: Cylinder port 1, Valve port 2, Pilot port 3
  • Clasificación de eficiencia del filtro: ISO 4406:1999 Code 18/16/13, ISO 4406 18/16/13, SAE Class 4
  • Tasa de fuga: 6 @ 1450 PSI (100 BAR) drops/min
  • Tamaño de la cavidad: 53-1
  • Par de instalación: 30 Nm, 22 lb-ft
  • Para tipo de fluido: Mineral-based or synthetic hydraulic fluids
  • Material de la válvula: All parts steel. All operating parts hardened steel
  • Temperatura máxima de funcionamiento: +250 °F, +121 °C
  • Temperatura mínima de funcionamiento: -30 °F, -34 °C
  • Peso: 0.17 lb, 0.08 kg

Información del artículo

Counterbalance valves are devices used to control cylinder and motor loads helping to restrict overrunning loads, assist with controlling speed and position for varying loads, and they are also used as load holding devices with built in thermal relieving functionality. Standard counterbalance valves are pilot operated devices that allow free flow in one direction and restricted flow in the opposite direction. The load is held in place until the counterbalance setting is overcome by sufficient pressure generated by the pump, thermal expansion, or from external forces acting on the actuator. Once the pressure falls below the required setting, the valve closes and holds the load in place. In order to save horsepower, pilot pressure assists in the opening of the valve allowing the load to be controlled with a lower than load induced pressure as long as the available pilot pressure is greater than the ratio between the valve setting and the selectable pilot ratio. Standard counterbalance valves are non-vented meaning the control spring chamber is connected to the valve outlet which will cause any downstream pressure to be additive the valves pressure setting. If excessive downstream pressure may be present or if the counterbalance pressure setting is critical, Parker also offers several series of externally vented counterbalance valves. Parker’s CB101, MHC-010-S, MHC-022-S, and E2 series of counterbalance valves are all standard non-vented load and motor control valves. Each series has multiple pilot ratio options, adjustment styles, and available pressure ranges. They can also be supplied with fixed factory settings, or with tamper proof caps. Typically higher pilot ratios are used for simple load holding applications where the moving load is controlled by external means and the main purpose of the counterbalance is to hold the load in position when not being operated, and to provide thermal and hose-break protection. Lower pilot ratios are typically used to assist in applications where cylinder or motor speed and positioning needs to be controlled with varying loads. Parker’s extensive line of counterbalance load and motor control valves allow design flexibility in the most demanding applications and markets including and not limited to: Power Units, Refuse, Oil and Gas, Material Handling, Construction, Drills, Presses, Mixers, Agriculture, Balers, Combines, Load Holding, Hose Break Protection, Overrunning load control

Leer más Mostrar menos

Diseños en CAD + Archivos


Documentos relacionados

×

Cantidad
Solicitar un presupuesto

El artículo se ha añadido correctamente a la cesta de presupuesto IR A MIS COTIZACIONES

x

OK

x

Encontrar un distribuidor

Puntos de venta

Contacto local

Latin American Group Headquarters

Parker Hannifin Ind. e Com. Ltda.

Estrada Municipal Joel de Paula, 900

São José dos Campos

SP

Brasil

12247-015

Consiga su cuenta de Parker hoy mismo!

Cree una cuenta para gestionar todo lo que haga con Parker, desde sus preferencias de compra hasta su acceso a la aplicación.

687852
327264