With high flow capacity and practically no flow limits, Parker's pilot operated proportional DC valve series D30FP in size NG10 (CETOP 05) delivers optimized cycle times and exceptional dynamic performance in a small footprint.


Especificaciones técnicas

  • Material de la junta: NBR
  • Conexión eléctrica: 4 - 20 mA
  • Ubicaciones de drenaje/entrada de piloto: Internal / internal
  • Marcado: Standard
  • Código del carrete: B60U
  • Conexión de solenoide: 6 + PE + enable
  • Posición del carrete: P-B at power down
  • Serie del producto: Proportional DC Valve
  • Conexión del puerto: NG10 / CETOP 05
  • Tipo de operación: Pilot
  • Tipo de electrónica: Onboard
  • Índice de caudal máximo: 250 L/min
  • Posición de montaje: Preferably Horizontal (other mounting positions after consultation)
  • Caudal: 80 / 40 L/min
  • Diferencia de presiones: 5 bar
  • Tipo de montaje: Subplate
  • Tipo de accionamiento: VCD®-Actuator
  • Para tipo de fluido: Hydraulic Oil According to DIN 51524 ... 535
  • Función: Proportional, 3-Way
  • Presión de trabajo máxima: 350 bar
  • Temperatura ambiente máxima: 60 °C
  • Temperatura ambiente mínima: -20 °C
  • Temperatura máxima del fluido: 60 °C
  • Temperatura mínima del fluido: -25 °C
  • Viscosidad cinemática máxima: 400 cSt
  • Viscosidad cinemática mínima: 20 cSt
  • Tasa de fuga: <1800 ml/min
  • Material de la junta: NBR
  • Peso: 6.5 kg
  • Estilo de montaje: DIN 24340, ISO 4401, CETOP RP121, NFPA
  • Clasificación de eficiencia del filtro: ISO 4406 18/16/13
  • Tiempo de respuesta: < 7 ms
  • Histéresis: < 0.05 %
  • Grado de protección de admisión: IP65 in accordance with EN 60529
  • Voltaje de suministro eléctrico: 24 V Nominal (tolerance range 22 … 30), Electric Shut-off at < 19 V Nominal (tolerance range 22 … 30), Ripple < 5 V % Eff., Surge Free V % Eff.
  • Resistencia a la vibración: 10 Sinus 5...2000 Hz Acc. IEC 60068-2-6, 10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64, 15 Shock Acc. IEC 60068-2-27
  • Material del cuerpo: Cast Iron
  • Aplicación: Industrial Hydraulic
  • Marca: Parker
  • Tecnología: Hydraulics
  • División: Industrial Systems Division Europe
  • Tipo de válvula: Proportional DC Valve
  • Medio: Hydraulic Oil

Información del artículo

Parker's series of pilot operated control valves D30FP enables higher product quality and shorter cycle times due to its outstanding dynamics. The high-precision control valve with VCD technology closes the gap between the direct operated D3FP valve and the conventional pilot operated D31FP valve. It provides high flow capacity and practically no flow limits like the D31FP in the envelope size of the D3FP. The valve works with the hydraulic follower principle, with a moving sleeve as main spool.

Version with EtherCAT interface
The DFplus valve series D30FP with EtherCAT (NG10) interface fulfills the requirements of modern communication between valve and main control. Due to high data transmission speed and short cycle times, the high dynamics of the DFplus valves can be also utilized within the fieldbus system.

Markets:
• Industrial
• Machine tools
• Molding

Features/Benefits:
• Compact design due to hydraulic follower principle - reduces valve footprint, for easier integration
• Exceptional dynamic performance from Parker's VCD® technology - optimized cycle times for continuous high productivity
• Very good repeatability - improved process and product accuracy
• Robust valve design - minimized failure
• Digital electronics - can be easily adapted to the application, resulting in flexible use
• Short delivery time - no warehousing necessary
• Defined spool positioning at power-down - optional P-A / B-T or P-B / A-T or center position (for overlapped spools)
• With EtherCAT interface upon request - high data speeds, short cycle times

Applications:
• Injection molding
• Machine tools

Technical specification EtherCAT version
The valve is actuated and monitored by the EtherCAT interface. Actual value (spool position), temperature, operating hours and different error messages are available as diagnostic signals. The valve parameters are factory set and can be adapted with the Parker ProPxD software via the parametrizing interface.

In addition to the fieldbus communication, the valves provide the range of functions of the standard version including  analogue command signal and diagnostic spare stroke. Thus they can be operated independent of the fieldbus control, particularly during commissioning and maintenance.

Leer más Mostrar menos

Diseños en CAD + Archivos


Documentos relacionados

×

Cantidad
Solicitar un presupuesto

El artículo se ha añadido correctamente a la cesta de presupuesto IR A MIS COTIZACIONES

x

OK

x

Encontrar un distribuidor

Puntos de venta

Contacto local

Latin American Group Headquarters

Parker Hannifin Ind. e Com. Ltda.

Estrada Municipal Joel de Paula, 900

São José dos Campos

SP

Brasil

12247-015

Consiga su cuenta de Parker hoy mismo!

Cree una cuenta para gestionar todo lo que haga con Parker, desde sus preferencias de compra hasta su acceso a la aplicación.

687852
687478