Engine feed shutoff valves are ball valves operated by 28 vdc motor actuators. Each valve is installed in an engine feed fuel line to prevent fuel from flowing into wing fire zones during an engine shutdown.


Especificaciones técnicas

  • Peso: 2.60 lb (Max)
  • Temperatura mínima del fluido: -58 °F
  • Temperatura máxima del fluido: +160 °F
  • Temperatura de funcionamiento: -67 deg F to +185 deg F ambient temperature °F
  • Presión de trabajo: 0 to 60 psig
  • Caída de presión: 0.05 psid max at 18.5 gpm with Jet A psi
  • Tasa de fuga interna: 15 drops/min max between -8 and 60 psig
  • Tasa de fuga externa: 0 drops/min between 0 and 120 psig

Información del artículo

Engine feed shutoff valves are ball valves that are comprised of an aluminum alloy body assembly and ball, PTFE-based ball seats, and a stainless steel drive shaft.  Each are installed with, and are operated by motor actuators that are powered at a nominal 28 VDC. Together, the engine feed shutoff valves and associated motor actuators provide a reliable, commanded capability to cut-off fuel flow to the engines within a few seconds.

Each engine feed shutoff valve is installed in an engine feed fuel line to prevent hazardous quantities of fuel from flowing into designated fire zones in the vacells. A thermal relief valve is incorporated in the design that bridges between the outlet and inlet sides of the ball to prevent excessive pressure build-up due to thermal expansion of the fuel in the fuel lines following an engine shutdown.

APPLICATIONS: Commercial

FEATURES AND ATTRIBUTES:
Parker Aerospace’s engine feed shutoff valve has a corrosion resistant, lightweight construction that weighs only 2.6 lb. The valve shares a design and fielded-service legacy of similar, reliable Parker fuel ball valves that goes back decades, with a guaranteed mean time between failure (MTBF) of 132,900 flight hours minimum.  The Engine Feed Shutoff Valve is certified for conducted current lightning strikes, and use with all standard, available aviation fuels including Jet A, Jet A-1, JP-5, JP-8, and TS-1.  

It can operate between 0 and 60 psig of fuel pressure in the fuel line, at fuel temperatures between -58 degrees F and +160 degrees F, and ambient operating temperatures between -67 degrees F and +185 degrees F.  Its operating time to open or close, when commanded, is between 2.5 and 8.5 seconds, depending on the actuator’s speed.

Leer más Mostrar menos

Diseños en CAD + Archivos

No hay archivo CAD disponible

OK

x

Documentos relacionados

×

Cantidad
Solicitar un presupuesto

El artículo se ha añadido correctamente a la cesta de presupuesto IR A MIS COTIZACIONES

x

OK

x

Encontrar un distribuidor

Puntos de venta

Contacto local

Latin American Group Headquarters

Parker Hannifin Ind. e Com. Ltda.

Estrada Municipal Joel de Paula, 900

São José dos Campos

SP

Brasil

12247-015

Consiga su cuenta de Parker hoy mismo!

Cree una cuenta para gestionar todo lo que haga con Parker, desde sus preferencias de compra hasta su acceso a la aplicación.

687852
687648