CDAS HL/LE 100-170 Large Flow Heatless Regeneration Compressed Air Treatment System | #CDASLE100-40N13BC


LOADING IMAGES
CDASLE100-40N13BC CDASLE100-40N13BC CDASLE100-40N13BC CDASLE100-40N13BC CDASLE100-40N13BC CDASLE100-40N13BC CDASLE100-40N13BC

CDAS HL/LE 100-170 Large Flow Heatless Regeneration Compressed Air Treatment System | #CDASLE100-40N13BC

Large flow, low energy compressed air treatment systems providing clean, dry air (CDA) for general industrial, automotive, electronics and semiconductor manufacturing.


Especificaciones técnicas

  • Tipo de bomba: Vacuum: HLVAP-OL-02-100 (Order Separately)
  • Tipo de conexión: NPT
  • Pressure Dew Point: -40°C (-40°F) or -20°C (-4°F) Option
  • Tamaño del puerto: 2"
  • Caudal: 408 m³/hr @ 7 barg, 35°C (240 cfm @ 102 psig, 95°F)
  • Grado ISO: Class 2.2.2 or Class 2.3.2
  • División: Gas Separation and Filtration Division EMEA
  • Marca: Parker
  • Tecnología: Filtration
  • Aplicación: Compressed Air Treatment - Clean Dry Air (CDA)
  • Tipo de productos: Compressed Air Dryer with Filtration
  • Estilo de productos: Vacuum Assisted Heatless Regeneration
  • Serie del producto: CDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)
  • Industria: • General Industrial Manufacturing
    • Automotive
    • Electronics & Semiconductor Manufacturing
  • Presión de trabajo: 5 to 13 barg
    (73 to 190 psig)
  • Temperatura de funcionamiento: 5 to 50°C
    (41 to 122°F)
  • Temperatura ambiente: 55°C (131°F) Maximum
  • Voltaje de suministro eléctrico: 400V +/-10% 3PH 50Hz (Standard)
    460V +/-10% 3PH 60Hz (Option)
  • Grado de protección de admisión: IP44
  • Nivel de ruido: <75 dB(A)
  • Cumplimiento con especificaciones: PED 2014/68/EU
  • Altura: 1647 mm
    (64.8 inch)
  • Anchura: 687 mm
    (27.0 inch)
  • Profundidad: 550 mm
    (21.7 inch)
  • Peso: 235 Kg
    (518 lbs)
  • Filtro incluido: Dryer Inlet
    General Purpose Coalescing Filter
    AOPX040HGFX
    and
    High Efficiency Coalescing Filter
    AAPX040HGFX

    Dryer Outlet
    General Purpose Dry Particulate Filter
    AOPX040HGFX

Información del artículo

Parker CDAS LE (Low Energy) Clean Dry Air Systems deliver clean, dry compressed air in accordance with all editions of ISO 8573-1, the international standard for compressed air quality. They are energy efficient and can provide pressure dewpoints of ≤-70°C, ≤-40°C or ≤-20°C at flow rates between 408 m³/hr and 2040 m³/hr @ 7 barg, 35°C for a single bank, higher flows available with multi-banking.

Using clean, dry compressed air improves productivity whilst reducing maintenance costs and downtime. Many products claim to provide this, however CDAS LE Clean Dry Air Systems provide high levels of compressed air purity with 3rd party validated performance in accordance with international standards.

Energy efficient, vacuum assisted heatless regeneration significantly reduces the volume of regeneration air (purge air) required to regenerate the offline desiccant column. The combined cost of operating the vacuum pump plus the generation cost of the reduced volume of purge air provides a dryer with an average energy saving of around 63% when compared to an equivalent heatless dryer.

Product Features
• Supplied with 4 Stages of purification, treating 7 of the 10 main compressed air contaminants (9 with optional liquid separator)
• Constant outlet dewpoint in accordance with ISO 8573-1 classes 1, 2 or 3 for water vapour
• Clean, dry purge air used for regeneration
• Dryer tested in accordance with ISO 7183
• Dewpoint performance 3rd party validated by LRQA
• Low energy vacuum assisted heatless regeneration
• No heat required for regeneration
• Inlet pressure, temperature and outlet dewpoint measurement as standard
• Colour HMI touch screen for dryer monitoring and outlet dewpoint display
• Two energy saving systems included as standard: Purge Economy (compressor synchronisation) and DDS-EST dewpoint dependant switching
• Web server for dryer monitoring via local area network (LAN)
• MODBUS TCP/IP & MODBUS RTU

To ensure quoted performance, a compressed air dryer must be sized using the correction factors found in the product information sheet.

To discuss your specific requirements please contact Parker or an authorised Parker distributor.

Leer más Mostrar menos

Diseños en CAD + Archivos

No hay archivo CAD disponible

OK

x

Documentos relacionados

×

Cantidad
Solicitar un presupuesto

El artículo se ha añadido correctamente a la cesta de presupuesto IR A MIS COTIZACIONES

x

OK

x

Encontrar un distribuidor

Puntos de venta

Contacto local

Latin American Group Headquarters

Parker Hannifin Ind. e Com. Ltda.

Estrada Municipal Joel de Paula, 900

São José dos Campos

SP

Brasil

12247-015

Consiga su cuenta de Parker hoy mismo!

Cree una cuenta para gestionar todo lo que haga con Parker, desde sus preferencias de compra hasta su acceso a la aplicación.

687852
A22066