Automated Bioprocessing System for Buffer Production - SciLog Single-Use Inline Dilution (ILD) | #805-ILD-40-220-3


LOADING IMAGES
805-ILD-40-220-3

Automated Bioprocessing System for Buffer Production - SciLog Single-Use Inline Dilution (ILD) | #805-ILD-40-220-3

Parker’s SciLog® Single-Use Inline Dilution (ILD) System is designed to offer a compact solution for point-of-use buffer needs.


Especificaciones técnicas

  • Voltaje de suministro eléctrico: 240V 3 Phase 20 amp
  • Aplicación: Normal Flow Filtration
  • Marca: SciLog
  • Industria: Pharmaceuticals
  • Tamaño: 53" L (135 cm) x 30" W (76 cm)
  • Voltaje de suministro eléctrico: 240 to 480 VAC Single or Three Phase, 20/15 Amps
  • Caudal: 5 to 60 L/min
  • Dilution Factor: 1x to 65x
  • Number of Inlets: 4 Concentrate Inlets, 1 WFI Inlet
  • Número de puntos de salida: 4 Buffer Outlets
  • Tipo de sensor: Pressure x3, Conductivity x2, PH x1, Coriolis Flow Meter x1-3
  • Software: SciSoft, DeltaV, Siemens
  • Interfaz de comunicación: MES; SCADA
  • Cumplimiento con especificaciones: CE, UL, RoHS, REACH, WEEE, System COC, Manifold MOC, Gamma Certificate, UPS VI, 21 CFR Part 11
  • Turn Over Package: Operations Manual, Major Component List, Major Component and Instrument Datasheets, Piping and Instrumentation Diagram, Material and Calibration Certificates, General Arrangement Drawing, System Drawings (As Built), Electrical Schematic (or design document), Control System Enclosure Drawings, Control System Schematics (As Built), Control System Cabinet General Layout, Control System Terminal Block Layout, Material and Calibration Certificates for all fluid contact surfaces, etc., Blank and executed copies of purchased qualification documents such as FAT, SAT

Información del artículo

Automated inline dilution is a process by which two liquid streams are brought together in a controlled fashion to meet a target concentration.

Inline dilution allows for more efficient and flexible process design by blending or diluting multiple buffers to the required concentrations at the point of use, resulting in smaller buffer batch sizes and thus a smaller facility footprint.

The SciLog lnline Dilution System can create buffers for downstream processes such as purification, chromatography, and adjustment steps or to dilute media for upstream processing.

Features and Benefits
• Compact footprint 53” L x 30” W (135 cm x 76 cm)
• WFI control via break bag or direct plant loop
• Point-of-use buffer creation in suite or at tank farm
• 5-60L/min output
• Irradiated single-use manifolds with unique single-use static mixer
• 4 concentrate inlets, 4 buffer outlets
• pH/Conductivity end points
• 40x dilution tested

Leer más Mostrar menos

Diseños en CAD + Archivos

No hay archivo CAD disponible

OK

x

Documentos relacionados

×

Cantidad
Solicitar un presupuesto

El artículo se ha añadido correctamente a la cesta de presupuesto IR A MIS COTIZACIONES

x

OK

x

Encontrar un distribuidor

Puntos de venta

Contacto local

Latin American Group Headquarters

Parker Hannifin Ind. e Com. Ltda.

Estrada Municipal Joel de Paula, 900

São José dos Campos

SP

Brasil

12247-015

Consiga su cuenta de Parker hoy mismo!

Cree una cuenta para gestionar todo lo que haga con Parker, desde sus preferencias de compra hasta su acceso a la aplicación.

687852
679945