REGIONAL - 3-way Pilot Operated, Threaded Cartridge Spool Valves used in normally closed or normally open directional control three way circuits requiring remote pilot actuation.


Especificaciones técnicas

  • Caudal: 10 GAL/MIN, 38 L/MIN
  • Configuración: Normally Closed
  • Presión de conmutación: 40 PSI, 2.8 BAR
  • Material de la junta: Fluorocarbon
  • Piloto hermético incluido: N/A
  • Dirección de flujo: 3-4 Neutral, 2-3 Piloted
  • División: Hydraulic Systems Division
  • Caudal: 10 gal/min, 38 L/min
  • Configuración: Normally Closed
  • Presión de conmutación: 40 psi, 2.8 bar
  • Material de la junta: Fluorocarbon
  • Piloto hermético incluido: N/A
  • Tipo de accionamiento: Pilot to shift
  • Índice de caudal máximo: 10 gal/min, 38 L/min
  • Ajuste de caudal estándar: N/A gal/min
  • Rango de presión de entrada máxima: 3500 psi, 240 bar
  • Presión de trabajo máxima: 3500 psi, 240 bar
  • Tasa de fuga: 50 @ 3500 PSI (240 BAR) cm3/min
  • Tamaño de la cavidad: C10-4
  • Función: Directional Control
  • Tipo de operación: Pilot operated
  • Dirección de flujo: 3-4 Neutral, 2-3 Piloted
  • Ubicación del piloto: External
  • Opción de drenaje: Internal
  • Para tipo de fluido: Mineral-based or synthetic hydraulic fluids
  • Viscosidad cinemática máxima: 45-2000 SSU (6 to 420 cSt)
  • Clasificación de eficiencia del filtro: ISO 4406 18/16/13, SAE Class 4
  • Material de la válvula: All parts steel. All operating parts hardened steel
  • Par de instalación: 16 lb-ft, 22 Nm
  • Temperatura de funcionamiento: -15 to +400 °F, -26 to +204 °C
  • Temperatura máxima de funcionamiento: +400 °F, +204 °C
  • Temperatura mínima de funcionamiento: -15 °F, -26 °C
  • Peso: 0.5 lb, 0.23 kg
  • Material del cuerpo: N/A

Información del artículo

Parker’s series of 3-way, pilot-operated directional control valves feature a strong design for maximum durability and performance that can operate with hydraulic system flows as high as 90 lpm and pressures up to 420 bar. The high pressure and flow capabilities of Parker’s selection make these valves suitable for high flow switching, diverting, bypassing, or unloading applications within a broad range of markets, such as the agriculture, construction, material handling and industrial markets.

Normally-open or normally-closed options are available depending on application needs, and can even be configured with a vent to atmosphere option for the spring chamber. Parker’s spring chamber vent to atmosphere design is especially beneficial when high pilot pressures are not readily available, which will help ensure proper valve and system functionality.

Markets:
• Aerial
• Agricultural Machinery
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• High flow capacity
• Multiple switching pressure options
• Sealed pilot option available
• Hardened working parts for maximum durability
• All external parts zinc plated

Applications:
• Bypass flow paths
• Diverter for hydrostatic transmission cooling or filtration
• Enabling/disabling functions
• Enabling/disabling hydraulic subsystems
• Regen functions

Additional Technical Insight:
Parker’s 3-way, pilot-operated series of directional control valves are available both normally-open and normally-closed, with flow and pressure ranging up to 90 lpm (24 gpm) and 420 bar (6,000 psi) respectively. Two versions of both the normally-open and normally-closed are available at varying flow and pressure ratings depending on the application needs. This series of valve acts as flow diverters and redirects the hydraulic fluid’s flow path from the valve’s neutral position to its shifted position by providing external pilot pressure to port 1 (nose) of the valve. The neutral or un-shifted position of the normally-open valves allow bidirectional flow from port 3 to port 2, with the 4th port blocked. When pilot pressure is provided to port 1, the spool shifts and then redirects the flow to between the 3rd and 4th port, blocking port 2. There is a selection of valves in this family that vent to atmosphere, allowing pressure equalization in the spring chamber. The remaining valves in this family vent the spring chamber internally through the 4th port, and as a result it is advised that port 4 is located on the lower pressure side of the valve and/or the tank line. Also, any additional pressure seen at port 4 is additive to the spring setting, which may impact the pilot pressure necessary to shift the valve. Pilot pressures of 2.8 bar (40 psi), 5.5 bar (80 psi), and 11 bar (160 psi) are available as standard options on the lower flow valves, and pilot pressures of 5 bar (73 psi) and 10 bar (145 psi) are available for the higher flow valves.

For all valves where the spring chamber is vented internally, the 4th port should be connected to the lower pressure flow path and/or ideally the tank line.

Leer más Mostrar menos

Diseños en CAD + Archivos


Documentos relacionados

×

Cantidad
Solicitar un presupuesto

El artículo se ha añadido correctamente a la cesta de presupuesto IR A MIS COTIZACIONES

x

OK

x

Encontrar un distribuidor

Puntos de venta

Contacto local

Latin American Group Headquarters

Parker Hannifin Ind. e Com. Ltda.

Estrada Municipal Joel de Paula, 900

São José dos Campos

SP

Brasil

12247-015

Consiga su cuenta de Parker hoy mismo!

Cree una cuenta para gestionar todo lo que haga con Parker, desde sus preferencias de compra hasta su acceso a la aplicación.

687852
327264