Parker Airtek TWP Series Externally Heated Desiccant Air Dryers use heat and the adsorption method to remove moisture from compressed air. Pressure dewpoint of -40°F (-40°C) and flowrate of 200 – 7500 scfm depending on model.

Especificaciones técnicas

  • Tipo de productos: Desiccant, Externally Heated, Desiccant, Externally Heated, Heated
  • Marca: Airtek
  • Accesorios opcionales: Pre and After Filtration
  • Tipo de conexión: 1” NPT , 1 1/2” NPT, 1 1/2" NPT, 2" NPT, 3" Flg, 4" Flg, 6" Flg, 8" Flg
  • Índice de caudal máximo: 170, 229, 340, 425, 510, 680, 850, 1019, 1359, 1699, 2038, 2548, 3398, 4417, 5097, 6796, 8495, 10194, 13592 m3/hour
  • Rango de presión de entrada máxima: 100 psi
  • Presión de trabajo máxima: 150, 135 psi
  • Presión mínima de trabajo: 80 psi
  • Temperatura máxima de funcionamiento: 120 °F
  • Temperatura mínima de funcionamiento: 50 °F
  • Temperatura ambiente máxima: 120 °F
  • Temperatura ambiente mínima: 40 °F
  • Índice de presión de purga: 7, 9.45, 14, 17.5, 21, 28, 35, 42, 56, 70, 84, 105, 140, 182, 210, 280, 350, 420, 560
  • Peso: 680, 720, 920, 1180, 1370, 1400, 2060, 2350, 3035, 4195, 5215, 7765, 8565, 11562, 12002, Consult Factory lb
  • Anchura: 31, 40, 43, 47, 50, 52, 63, 74, 78, 96, Consult Factory inch
  • Profundidad: 18, 22, 27, 28, 35, 41, 60 inch
  • Altura: 83 - 113 inch
  • Prefiltro compatible: JC0110-C, JC0150-C, JC0250-C, JC0350-C, JC0450-C, JC0625-C, JC0800-C, JC1000-C, JLA1603-C, JLA2100-C, JLA3200-C, JLA3206-C, Consult Factory
  • Filtro posterior compatible: JC0150-FH, JC0250-FH, JC0350-FH, JC0450-FH, JC0625-FH, JC0800-FH, JC1000-FH, JLA1800-FH, JLA2600-FH, JLA3506-FH, Consult Factory
  • Elemento de prefiltro compatible: JE-CC0110, JE-CC0150, JE-CC0350, JE-CC0450, JE-CC0625, JE-CC0800, (2) JAE3-C, (3) JAE3-C, (4) JAE3-C, Consult Factory
  • Elemento de filtro posterior compatible: JE-FC0150-HT, JE-FC0350-HT, JE-FC0450-HT, JE-FC0625-HT, JE-FC0800-HT, JAE4-FH, (2) JAE4-FH, (3) JAE3-FH, Consult Factory
  • Tipo de drenaje de agua condensada instalado: Timed Solenoid Drain, Demand Solenoid Drain

Descripción completa del producto

Compressed air is polluted with dirt particles, water, oil, oil vapor, and condensate.  These contaminants result in high maintenance costs, premature wear, spoiled products and the failure of control systems.

A Parker Airtek TWP Series Externally Heated Desiccant Air Dryer will effectively remove contaminants such as dirt, water, and oil. The traditional adsorption principle used in this design is simple, robust and flexible. Continuous drying is accomplished by the operation of two desiccant towers.

Compressed air is dried through one tower while the other desiccant tower is being regenerated. The regeneration heating cycle of desiccant is accomplished using a dry air purge flow heated by an external electric heater. The regeneration cooling cycle is performed using the same flow of dry compressed air taken from the desiccant air dryer outlet to ensure continuous dewpoint performance.

Features/Benefits
• Flow rate starting at 200 scfm (340 m3/hr)
• Delivered air quality is in accordance with ISO 8573.1: 2001, the international standard for compressed air quality.
• Pressure dewpoints of -100°F (-70°C) & -40°F (-40°C) (ISO 8573.1: 2001 Classes 1 & 2) are available.
• Parker Airtek pre- and after compressed air filters - Standard
• PowerLoc Energy Management System* - Standard
• Low-wattage high incoloy sheathed heater for efficient regeneration
• High-efficiency, quiet running regenerative (up to 3000 scfm) or centrifugal blowers (4000 scfm and larger)
• Parker non-lubricated full-flow angle seat valves, which carry a FIVE YEAR VALVE WARRANTY, are standard on dryers up to 800 scfm.
• High performance, actuated butterfly switching valves, which carry a FIVE YEAR VALVE WARRANTY, are standard on dryers 1000 scfm and larger.
• Insulated tower, heater and purge lines increase dryer performance and efficiency by reducing radiant heat loss plus keeps the unit with the safety parameters set forth by OSHA.
• Easy to use Control Center affords superior dryer control along with digital telemetry for remote analysis of performance.
• Custom filter packaging*
• 7” HMI, Allen-Bradley® PLC
• Flash drive port for transferring data log
• Serial communications port (optional)
• Emergency stop and standby mode
• Automatic data logging 24/7, 365 days of all
operational information

*Optional equipment

Documentos relacionados

×
Productos Índice de caudal máximo (cfm) Requisitos eléctricos Punto de rocío a presión (F)
TWP201BY21NNN 200 240V/1Ph/60Hz -40
TWP251BY21NNN 250 240V/1Ph/60Hz -40
TWP301BY41NNN 300 460V/3Ph/60Hz -40
TWP401BY41NNN 400 460V/3Ph/60Hz -40
TWP501BY41NNN 500 460V/3Ph/60Hz -40
TWP601BY41NNN 600 460V/3Ph/60Hz -40
TWP801BY41NNN 800 460V/3Ph/60Hz -40
TWP1001FY41NNN 1000 460V/3Ph/60Hz -40
TWP1201FY41NNN 1200 460V/3Ph/60Hz -40
TWP1501FY41NNN 1500 460V/3Ph/60Hz -40
TWP2001FY41NNN 2000 460V/3Ph/60Hz -40
TWP2601FY41NNN 2600 460V/3Ph/60Hz -40
TWP3001FY41NNN 3000 460V/3Ph/60Hz -40
TWP4001FY41NNN 4000 460V/3Ph/60Hz -40
TWP5001FY41NNN 5000 460V/3Ph/60Hz -40
TWP6001FY41NNN 6000 460V/3Ph/60Hz -40
TWP8001FY41NNN 8000 460V/3Ph/60Hz -40

687852