K-MT 1-8 Series Heatless Compressed Air Dryer

K-MT 1-8 Series Heatless Compressed Air Dryer

Compact, heatless compressed air dryers for applications requiring volume flows up to 86m³/h @ 7 barg and dew points of -40°C (-25°C and -70°C options).

Especificaciones técnicas

  • División: Gas Separation and Filtration Division EMEA
  • Marca: Parker
  • Tecnología: Filtration
  • Aplicación: Compressed Air Applications
  • Tipo de productos: Compressed Air Dryer
  • Estilo de productos: Heatless
  • Serie del producto: K-MT 1-8
  • Industria: Industrial Manufacturing Equipment
    Food & Beverage
    Automotive
    Electronics
    Pharmaceuticals
    Medical & Dental
  • Caudal: 8 to 86 m3/hour at 7 barg, 5 to 51 CFM at 102 psig
  • Punto de rocío a presión: Standard: -40°C (-40°F)
    , Options: -70°C (-100°F) or -20°C (-4°F)
  • Grado ISO: Standard: Class 2.2.1
    Options: Class 2.1.1 or Class 2.3.1
  • Presión de trabajo: 4 to 16 barg, 58 to 232 psig
  • Temperatura de funcionamiento: 5 to 50 °C, 41 to 122 °F
  • Temperatura ambiente: 50.0 °C Maximum, 122.0 °F Maximum
  • Requisitos eléctricos: Standard: 85 - 265V 1ph 50/60Hz
    Optional: 115V 1ph 50/60Hz 24V DC
  • Tamaño del puerto: 1/4 to 3/4 inch
  • Tipo de conexión: BSPP
  • Grado de protección de admisión: IP65 Indoor and Frost Free Installation Only
  • Cumplimiento con especificaciones: PED 2014/68/EU Fluid Group II
  • Nivel de ruido: 65 to 86 dBA
  • Altura: 434 to 1589 mm, 17 to 63 inch
  • Anchura: 486 to 692 mm, 19.0 inch, 27.0 inch
  • Profundidad: 210.0 mm, 300.0 mm, 8 inch, 12 inch
  • Peso: 15 to 92 Kg
    (33 to 203 lbs)

Descripción completa del producto

The Parker K-MT 1-8 range of heatless adsorption dryers are designed to dry industrial compressed air reliably and efficiently down to a pressure dew point of -40°C (-25°C and -70°C options available). The units are compact and can be installed either free-standing or wall mounted. They come equipped with integrated high performance OIL-X pre- and after filtration and are capable of volume flows up to 86 m³/h in a system operating at 7 barg (100 psig).

Features
• Pressure dew points down to -40°C (-25°C and -70°C options available)

• Volume flows up to 86 m³/h @ 7 barg (100 psig)

• High performance pre- and after filters installed as standard

• Energy saving dew point dependent switching (DDS) as an option

Benefits
• Highest quality air

• Compact and space saving

• Energy efficient

• Very flexible due to a wide range of options and accessories

Energy Savings
Where an application calls for a unit able to cope with variations in operating pressure and load, the installation of a dew point sensor at the outlet of the dryer is available as an option. In such an operating mode, the changeover cycle between chambers only takes place when required, and is dependent on the required dew point being achieved. Only upon reaching this adjustable set dew point, does changeover to the regenerated chamber occur. This feature enables the drying phase to be lengthened and thus avoids the unnecessary use of purge air for regeneration and consequently provides energy savings.

Compressed air can be selectively dried to meet a dew point of -25°C down to -70°C.

Sizing and Selection
To ensure quoted air purity performance is met, a compressed air dryer must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the Product Information Sheet.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.

Documentos relacionados

×
Productos Caudal Requisitos eléctricos Tamaño del puerto Accesorios opcionales
K1/16D3-G24DM 8 m³/h @7 barg (5 cfm @102 psig) 24V DC ¼ inch None
K2/16D3-G24DM 15 m³/h @7 barg (9 cfm @102 psig) 24V DC ¼ inch None
K3/16D3-G24DM 25 m³/h @7 barg (15 cfm @102 psig) 24V DC ¼ inch None
K4/16D3-G24DM 35 m³/h @7 barg (21 cfm @102 psig) 24V DC ¼ inch None
K6/16D3-G24DM 56 m³/h @7 barg (33 cfm @102 psig) 24V DC ½ inch None
K7/16D3-G24DM 72 m³/h @7 barg (42 cfm @102 psig) 24V DC ½ inch None
K8/16D3-G24DM 86 m³/h @7 barg (51 cfm @102 psig) 24V DC ¾ inch None
K1/16D3-G230M 8 m³/h @7 barg (5 cfm @102 psig) 230V 1ph 50/60Hz ¼ inch None
K1/16D3-G230MT 8 m³/h @7 barg (5 cfm @102 psig) 230V 1ph 50/60Hz ¼ inch Pre-installed Dew Point Sensor
K2/16D3-G230M 15 m³/h @7 barg (9 cfm @102 psig) 230V 1ph 50/60Hz ¼ inch None
K2/16D3-G230MT 15 m³/h @7 barg (9 cfm @102 psig) 230V 1ph 50/60Hz ¼ inch Pre-installed Dew Point Sensor
K3/16D3-G230M 25 m³/h @7 barg (15 cfm @102 psig) 230V 1ph 50/60Hz ¼ inch None
K3/16D3-G230MT 25 m³/h @7 barg (15 cfm @102 psig) 230V 1ph 50/60Hz ¼ inch Pre-installed Dew Point Sensor
K4/16D3-G230M 35 m³/h @7 barg (21 cfm @102 psig) 230V 1ph 50/60Hz ¼ inch None
K4/16D3-G230MT 35 m³/h @7 barg (21 cfm @102 psig) 230V 1ph 50/60Hz ¼ inch Pre-installed Dew Point Sensor
K6/16D3-G230M 56 m³/h @7 barg (33 cfm @102 psig) 230V 1ph 50/60Hz ½ inch None
K6/16D3-G230MT 56 m³/h @7 barg (33 cfm @102 psig) 230V 1ph 50/60Hz ½ inch Pre-installed Dew Point Sensor
K7/16D3-G230M 72 m³/h @7 barg (42 cfm @102 psig) 230V 1ph 50/60Hz ½ inch None
K7/16D3-G230MT 72 m³/h @7 barg (42 cfm @102 psig) 230V 1ph 50/60Hz ½ inch Pre-installed Dew Point Sensor
K8/16D3-G230M 86 m³/h @7 barg (51 cfm @102 psig) 230V 1ph 50/60Hz ¾ inch None
K8/16D3-G230MT 86 m³/h @7 barg (51 cfm @102 psig) 230V 1ph 50/60Hz ¾ inch Pre-installed Dew Point Sensor
K1/16D3-N115M 8 m³/h @7 barg (5 cfm @102 psig) 115V 1ph 50/60Hz ¼ inch None
K2/16D3-N115M 15 m³/h @7 barg (9 cfm @102 psig) 115V 1ph 50/60Hz ¼ inch None
K3/16D3-N115M 25 m³/h @7 barg (15 cfm @102 psig) 115V 1ph 50/60Hz ¼ inch None
K4/16D3-N115M 35 m³/h @7 barg (21 cfm @102 psig) 115V 1ph 50/60Hz ¼ inch None

687852