Supplemental coolant additives can be used instead of coolant filters to replenish the cooling system when depleted.

Technical Specifications

  • Brand: Baldwin

Full Product Description

Liquid supplemental coolant additives can be used instead of coolant filters to replenish the cooling system when depleted. Periodic testing of coolant mixtures should be done to ensure proper chemical levels are maintained. The service sticker inside the driver side door indicates which type of additive the system requires (BTE or BTA PLUS).

Related Documents

×
Products Product Type Contains Notes Related To Compatible Competitor Part Number
CS5008 BTE Liquid Coolant Additive (Pint Plastic Bottle) Pre-Charge treatment is one pint to each 4 gallons of cooling system capacity or fraction.; Maintenance treatment is one pint for each 20 gallons of cooling system capacity or fraction. Every 12,000-15,000 miles or 300-350 hours of operation. NOT compatible with Long Life Organic Acid-based Coolant.; For systems containing 40% to 60% Ethylene Glycol antifreeze.; Compatible with all Ethylene Glycol antifreezes.; Heavy-Duty antifreeze containing sodium nitrite needs no initial treatment.
CS5007 BTA PLUS Formula Liquid Additive (Pint Plastic Bottle) 4 Units BTA PLUS; Pre-Charge treatment is 1 1/4 units per gallon of cooling system capacity.; Maintenance treatment is 1 1/4 units per 4 gallons of cooling system capacity every 12,000-15,000 miles or 300-350 hours of operation. NOT compatible with Long Life Organic Acid-based Coolant.; For systems containing 0% to 60% Ethylene Glycol antifreeze. CS5055 (55 Gallon Drum); CS5057 (5 Gallon Jug); CS5058 (Half Gallon Jug) Case B91245; Cummins 3305372, 3315459; John Deere RE23182, TY16004
CS5009 BTE Liquid Coolant Additive (Half Gallon Plastic Jug) Pre-Charge treatment is one pint to each 4 gallons of cooling system capacity or fraction.; Maintenance treatment is one pint for each 20 gallons of cooling system capacity or fraction. Every 12,000-15,000 miles or 300-350 hours of operation. NOT compatible with Long Life Organic Acid-based Coolant.; For systems containing 40% to 60% Ethylene Glycol antifreeze.; Compatible with all Ethylene Glycol antifreezes.; Heavy-Duty antifreeze containing sodium nitrite needs no initial treatment.
CS5058 BTA PLUS Formula Liquid Additive (Half Gallon Jug) NOT compatible with Long Life Organic Acid-based Coolant.; Pre-Charge treatment is 1 1/4 units per gallon of cooling system capacity.; Maintenance treatment is 1 1/4 units per 4 gallons of cooling system CS5007 (Pint Bottle); CS5055 (55 Gallon No Return Plastic Drum); CS5057 (5 Gallon Bucket) Cummins 3305373; Komatsu 1258390-H1
CSC5012 Liquid Coolant Cleaner (1 Gallon Plastic Bottle) Recommended treatment is 1 gallon to each 10 gallons of cooling system capacity. While you may get improved performance from a higher concentration of CSC, do not use CSC at more than twice the recommended concentration levels. An inhibited neutral chelating cooling system cleaner. CSC is formulated to dissolve scale and corrosion products while removing silica gel and oil found in engine cooling systems.
CSC5013 Liquid Coolant Cleaner (5 Gallon Jug) Recommended treatment is 1 gallon to each 10 gallons of cooling system capacity. While you may get improved performance from a higher concentration of CSC, do not use CSC at more than twice the recommended concentration levels. An inhibited neutral chelating cooling system cleaner. CSC is formulated to dissolve scale and corrosion products while removing silica gel and oil found in engine cooling systems.
CS5010 BTE Liquid Coolant Additive (5 Gallon Bucket) Pre-Charge treatment is one pint to each 4 gallons of cooling system capacity or fraction.; Maintenance treatment is one pint for each 20 gallons of cooling system capacity or fraction. Every 12,000-15,000 miles or 300-350 hours of operation. NOT compatible with Long Life Organic Acid-based Coolant.; For systems containing 40% to 60% Ethylene Glycol antifreeze.; Compatible with all Ethylene Glycol antifreezes.; Heavy-Duty antifreeze containing sodium nitrite needs no initial treatment.
CS5057 BTA PLUS Liquid Additive (5 Gallon Jug) NOT compatible with Long Life Organic Acid-based Coolant.; Pre-Charge treatment is 1 1/4 units per gallon of cooling system capacity.; Maintenance treatment is 1 1/4 units per 4 gallons of cooling system CS5007 (Pint Bottle); CS5055 (55 Gallon No Return Plastic Drum); CS5058 (Half Gallon Jug) Caterpillar 8C3680
CS5011 BTE Liquid Coolant Additive (55 Gallon No Return Plastic Drum) Pre-Charge treatment is one pint to each 4 gallons of cooling system capacity or fraction.; Maintenance treatment is one pint for each 20 gallons of cooling system capacity or fraction. Every 12,000-15,000 miles or 300-350 hours of operation. NOT compatible with Long Life Organic Acid-based Coolant.; For systems containing 40% to 60% Ethylene Glycol antifreeze.; Compatible with all Ethylene Glycol antifreezes.; Heavy-Duty antifreeze containing sodium nitrite needs no initial treatment.
CS5055 BTA PLUS Liquid Additive (55 Gallon No Return Plastic Drum) NOT compatible with Long Life Organic Acid-based Coolant.; Pre-Charge treatment is 1 1/4 units per gallon of cooling system capacity.; Maintenance treatment is 1 1/4 units per 4 gallons of cooling system CS5007 (Pint Bottle); CS5057 (5 Gallon Bucket); CS5058 (Half Gallon Jug)